USING YOUR OIL FILLED RADIATOR
•
Before connecting your appliance to the mains socket,
position the appliance upright on the floor, at least 100cm
away from the wall, away from curtains, furniture or wall
coverings.
•
Insert the mains plug into a suitable 13 amp mains socket.
•
This appliance operates through a digital control to set the
temperature. Once a temperature is selected, after <20
minutes the appliance should reach the desired temperature.
•
Your heater has the ability to operate continuously, up to a
desired temperature, or on a timer.
Continuous Operation
1. Turn on the Power Switch (6).
2. To set the heater power, press Power Button (5) to cycle
between High Power, Medium Power, and Low Power
i.
Please note under this setting, operation will be
continuous until either the appliance is switched off, or
the ambient room temperature reaches 30°C
3. To reduce heat, press the power button.
4. To switch off, press the power button 4 times.
Temperature Control
1. Ensure the Heater is in Standby Mode by pressing the Power
Button.
i.
You will know it is in standby when the display screen
blinks every 1 second.
2.
Press the ‘MODE’ button. The display will change to a
temperature reading and blink.
3.
Press the ‘+’ or ‘
-
’ buttons to set a desired temperature
between 13°C and 30°C.