R46A-11TDW

ERV UNIT SCHE MATIC DIAGRAM

Notes:
1.

Remove jumper to install field optional low ambient switch.

2.

Step-down transformer assembly for 460 volt units.

3.

Selective voltage terminal for proper unit voltage

4.

Optional low ambient switch.

5.

Optional motorized intake damper.

6.

Optional stop, start and jog control.

7.

Matching adapter harness (provided) to connect with rooftop unit. For energy
management systems c24v to green and common 24v to black.

COM PO NENT  CODE

A131

Fixed Re lay Board

B26

Mo tor,  Ex haust  Air

B27

Mo tor, Fresh Air

B28

Mo tor,  Des ic cant  Wheel

B30

Mo tor, Damper (Op tional)

C23

Ca paci tor,  Wheel  Mo tor

DL43

De lay, Cy cle Timer (Op tional)

F29

Fuse

J33

Jack, Cy cle Con trol (Op tional)

J34

Jack, Cy cle Con trol Har ness (Op tional)

J40

Jack, Cy cle  (Op tional)

J48

Jack, Con trol Box (Fresh Air)

J50

Jack, Con trol Box (Wheel)

J51

Jack, Con trol Box (Ex haust Air)

J56

Jack, Con trol Box (Damper)

J148

Jack, Fresh Air Mo tor Har ness

J150

Jack, Wheel Mo tor Har ness

J151

Jack, Ex haust Air Mo tor Har ness

J152

Jack, Trans former (High Volt age)

J153

Jack, Field Har ness

J160

Jack, Damper Mo tor Har ness

K94

Re lay, On/Off (Op tional)

K163

Con tac tor,  Ex haust  Air  Mo tor

K164

Con tac tor, Fresh Air Mo tor

P33

Plug, Cy cle Con trol (Op tional)

P34

Plug, Cy cle Con trol Har ness (Op tional)

P40

Plug, Wheel Cy cle (Op tional)

P48

Plug, Fresh Air Mo tor Har ness

P50

Plug, Wheel Mo tor Har ness

P51

Plug, Ex haust Air Mo tor Har ness

P56

Plug, Damper Mo tor Har ness

P148

Plug, Fresh Air Mo tor

P150

Plug, Wheel Mo tor

P151

Plug, Ex haust Air Mo tor

P152

Plug, Trans former (High Volt age)

P153

Plug, Field Har ness

P160

Plug, Damper Mo tor

S23

Ther mo stat  -  Low  Am bi ent  (Op tional)

S26

Switch, Low Am bi ent (Op tional)

S51

Switch, Door

S125

Switch,  Am bi ent  Over ride  (Op tional)

T27

Trans former,  Con trol

T28

Trans former,  Step- down  (Op tional)

WIRE COLOR

BK

Black

BL

Blue

GR

Green

GY

Gray

OR

Or ange

Содержание RRS Systems YCD

Страница 1: ...ing the Energy Recovery Wheel ERW within the cassette frame work In winter the ERW adsorbs heat and moisture from the exhaust air stream during one half of a complete rotation and gives them back to t...

Страница 2: ...in place 16 Seal if required along face top and sides of ERV unit where it meets rooftop unit to insure no air leakage 17 All electrical connections must conform to any local codes and current Nationa...

Страница 3: ...how the frost threshold temperatures vary depending on indoor conditions FROST THRESHOLD TEMPERATURE INDOOR RH AT 70o F FROST THRESHOLD TEMPERATURE 20 0o F 30 5o F 40 10o F Because Energy Recovery Ve...

Страница 4: ...with water and or mild detergent To install wheel segments follow steps A through E See Figure 5 Reverse procedure for segment removal A Unlock two segment retainers one on each side of the selected...

Страница 5: ...25 1 18 1 10 1 20 1 20 1 19 1 18 1 16 1 13 1 10 1 03 0 98 0 93 0 85 0 78 0 60 0 91 0 90 0 89 0 88 0 85 0 80 0 75 0 69 0 65 0 57 0 48 0 37 0 22 0 00 0 20 0 40 0 60 0 80 1 00 1 20 1 40 1 60 2200 2400 26...

Страница 6: ...0 Jack Control Box Wheel J51 Jack Control Box Exhaust Air J56 Jack Control Box Damper J148 Jack Fresh Air Motor Harness J150 Jack Wheel Motor Harness J151 Jack Exhaust Air Motor Harness J152 Jack Tran...

Страница 7: ...ambient switch 2 Step down transformer assembly for 460 volt units 3 Selective voltage terminal for proper unit voltage 4 Optional low ambient switch 5 Optional motorized intake damper 6 Optional sto...

Страница 8: ...PAGE 8...

Отзывы: