Rupert Neve Designs Shelford 5051 Скачать руководство пользователя страница 3

5051: Front Panel

-15

+15

0

-15

+15

0

-15

+15

0

-6dB

+20

100mS

2.5 S

250

1 S

-30dB

+20dB

-10

+10

GAIN

1.1:1

40:1

RATIO

1.5:1

3:1

FF

FB

LO PEAK

8K

16K

THRESH

S/C HPF

RELEASE

LINK

5mS

75mS

ATTACK

25

50

COMP IN

EQ IN

EQ PRE

POST

220

100

60

35

MID FREQ

MID HI Q

LOW FREQ

0

22
20
18
14
10

4

-2

-10

1
2
4
6

10
14
18
22

Level

GR

3K

1.5K

700

350

200

6K

HF

MID

LF

HI PEAK

HPF

Red 120Hz

Blue 60Hz

I

NDUCTOR EQ

5051

EQ/Compressor

C

OMPRESSOR

LINE 1

LINE 2

 

Threshold

Sets the level at which

compression begins

Ratio

Changes the amount of

gain reduction above the set

threshold level

Attack Time

Changes the time delay

before compression begins

Release Time

Changes the time taken for

the gain return to 0 after the

compressor disengages

SC HPF

Applies a HPF at 250 Hz to the

VCA side chain signal

FF/FB

When engaged, changes the VCA

detection from feed-forward to

feed-back

Level & Gain Reduction Meters

8 segment LED Meter for 

monitoring gain reduction

and output level

Comp IN

Engages the Compressor

Make-Up Gain

Applies post-compressor 

make-up gain

Link

Links the 5051 VCA to the 5051

module to which it is connected

HPF

Line Select

Mid Parametric

Low Frequency EQ

High Frequency Shelf / Peak

Cycles between bypassed, HPF at 

60 HZ, and HPF at 120Hz

Selects between line 1 and 

line 2

Selectable at 35, 60, 100, and 

220 Hz.  Continuous gain from -15 to 

+15dB Selectable peak or shelf curves.

Selectable at 200, 350, 700,

 1.5 K, 3 K, and 6 KHz.  With 

continuous gain from -15 to 

+15dB.  Selectable Hi Q.

Selectable at 8 and 16 Khz.  With 

continuous gain from -15 to +15dB.

Selectable peak or shelf curves

EQ Pre / Post

When engaged, moves the 

EQ after the compressor 

Содержание Shelford 5051

Страница 1: ...By Serial Operations Manual Shelford 5051 Inductor EQ Compressor...

Страница 2: ...Do not block any ventilation openings Install in accordance with the manufacturer s instructions 8 Do not install near any heat source such as radiators heat registers stoves or other apparatus inclu...

Страница 3: ...ges SC HPF Applies a HPF at 250 Hz to the VCA side chain signal FF FB When engaged changes the VCA detection from feed forward to feed back Level Gain Reduction Meters 8 segment LED Meter for monitori...

Страница 4: ...rt is a half normal connection so if there is no signal on the S C insert return when it is plugged in there will not be any compression Power In 4 pin power connection with 24V DC from specialized 50...

Страница 5: ...io is obtained in the interest of intelligibility within the limited performance of say a reporter s recording device Digital recorders are unforgiving when overloaded Overload can be avoided with car...

Страница 6: ...n control or fader consisting of a high quality variable resistor that by definition has a linear transfer characteristic A dynamics controller i e a compressor limiter or expander is a gain control t...

Страница 7: ...08 HOW THE 5051 COMPRESSOR WORKS A part of the audio signal is rectified and smoothed to produce a suitable control voltage for the VCA which has to respond very quickly and have low distortion If the...

Страница 8: ...om the Portico II Master Buss Processor the 5051 can be configured within a 5088 console to deliver exceptional tonal and dynamic control on each channel Traditional transformer coupled inputs and out...

Страница 9: ...a Mid Hi Q switch to narrow the bandwidth increase the Q of the filter The 5051 includes an 18 dB octave high pass filter with cutoff frequencies on a button that toggles through OFF 60 Hz and 120 Hz...

Страница 10: ...y the amount of boost or cut gradually diminishes With the HI PEAK button pressed the high frequency band changes to peak mode with a bell shaped boost or cut curve The Peak mode utilizes an inductor...

Страница 11: ...er back to off or bypass which extinguishes the LED LOW FREQ The LOW FREQ rotary switch has 4 positions for selecting one of four corner or center frequencies for the low band EQ section The frequenci...

Страница 12: ...cluding pumping and a slight modulation distortion in the presence of loud low notes Medium settings are sometimes nice for having the compression act in time with the music Slow release settings tend...

Страница 13: ...to choosing compressor settings than meters The meter will generally indicate very brief gain reductions but will tend to exaggerate the duration so that the eye can see transient compression LEVEL M...

Страница 14: ...nto the link out jack Plug the other end of the cable into the link in jack of the 5051 to its right In the same way connect all of the 5051 units together LINE 1 XLR female transformer balanced float...

Страница 15: ...Noise from 10 Hz to 80 kHz 1kHz 20 dBu output Better than 0 007 20Hz 20 dBu out Better than 0 120 20kHz 20 dBu out Better than 0 070 The Compressor Threshold at 20 dB Ratio at 1 1 1 Gain at 0 Noise M...