background image

 

3. Press

to finish adjustment, press

  to return. 

Regeneration 

Time 

1. Under the Regeneration Time display status, press

to 

enter  into  program  set  mode.  Regeneration  hour  value 

flashes, press

  or 

  to adjust the hour value. 

2.Press

again, regeneration minute value flashes, press 

or 

  to adjust the minute value. 

3. Press

  to finish adjustment, press

  to return. 

 

Control Mode 

1.  Under  the  Control  Mode  display  status,  Press

  to 

enter into program set mode. 

Control  mode  A-01  flashes,  press

  or

  to  adjust  the 

working mode. 

2. Press

  to finish adjustment, press

  to return. 

 

Water 

Treatment 

Capacity 

1.  Under  the  Water  Treatment  Capacity  display  status, 

Press

  enter  into  program  set  mode.  Water  treatment 

capacity  integer  value  flashes,  press

  or 

  to  adjust 

the value. 

2.Press

again,  water  treatment  capacity  decimal  value 

flashes, press

  or 

  to adjust the decimal value. 

3. Press

  to finish adjustment, press

  to return. 

 

Backwash Time 

1.  Under  the  Backwash  Time  display  status,  Press

 

enter into program set mode. Backwash time value flashes, 

press

  or 

  to adjust the value. 

2. Press

  to finish adjustment, press

  to return. 

 

Brine & Slow 

Rinse Time 

1. Under the Brine& Slow Rinse Time display status, Press

  enter  into program  set  mode.  Brine  &  slow  rinse  time 

value flashes, press

  or 

  to adjust the value. 

2. Press

  to finish adjustment, press

  to return. 

 

Brine Refill 

Time 

1.  Under  the  Brine  Refill  Time  display  status,  Press

 

enter into program set mode. Brine refill time value flashes, 

press

  or 

  to adjust the value. 

2. Press

  to finish adjustment, press

  to return. 

 

Fast Rinse 

Time 

1.  Under  the  Fast  Rinse  Time  display  status,  Press

 

enter into program set mode. Fast rinse time value flashes, 

press

  or 

  to adjust the value. 

2. Press

  to finish adjustment, press

  to return. 

 

Maximum 

Interval 

Regeneration 

Days 

1. Under the Maximum Interval Regeneration Days display 

status,  Press

  enter  into  program  set  mode.  Maximum 

interval  regeneration  days  value  flashes,  press

  or 

 

to adjust the value. 

 

Содержание N74Q1

Страница 1: ...sage 1 1 The Function of PC Board A Button lock indicator When the fourth decimal point of digital tube turns on it indicates the buttons are locked At this moment any single button will not work No operation in one minute the fourth decimal point of the digital tube will light on and lock the buttons Solution Press and hold both and for 5 seconds until the decimal point lights off ...

Страница 2: ...es washing status instantly if the outlet water is unqualified Press while it is in regeneration washing status it will end regeneration washing in advance and go to the next status at once F Down and Up In program display mode press or to view all values In program set mode press or to adjust values Press and hold both and for 5 seconds to unlock the buttons In program set mode press to return to...

Страница 3: ... adjustment press to return Backwash Time 1 Under the Backwash Time display status Press enter into program set mode Backwash time value flashes press or to adjust the value 2 Press to finish adjustment press to return Brine Slow Rinse Time 1 Under the Brine Slow Rinse Time display status Press enter into program set mode Brine slow rinse time value flashes press or to adjust the value 2 Press to ...

Страница 4: ...f you want to set the time as 15 minutes the modification steps as follows Press and hold both and to unlock the button The fourth decimal point of digital tube lights off Press the third decimal point of digital tube lights on Press or continuously until in fast rinse status the digital display area shows 5 12M Press 12 flashes Press the continuously until 12 changes to 15 Press again and hear a ...

Отзывы: