background image

53524 (F139)
51524 (F139S)

Multi-functional Flow Control Valve for 

Swimming Pool System

Instruction Manual

              Please read this manual in details 

 before using this valve and keep it properly

 in order to consult in the future 

0WRX.466.756

WENZHOU RUNXIN MANUFACTURING MACHINE CO.,LTD 

 

ADD: NO.169, RUNXIN ROAD, SHANFU TOWN, WENZHOU, ZHEJIANG, CHINA.

TEL.:0086-577-88630038, 88576512, 85956057         FAX:0086-577-88633258

E-MAIL: [email protected]        http://www.run-xin.com

Rev.A. 108

2

Содержание 51524

Страница 1: ...in details before using this valve and keep it properly in order to consult in the future 0WRX 466 756 WENZHOU RUNXIN MANUFACTURING MACHINE CO LTD ADD NO 169 RUNXIN ROAD SHANFU TOWN WENZHOU ZHEJIANG...

Страница 2: ...t mm Refilled Filter Material Kg Granularity of Filter Material mm Control Valve Model Number Pressure of Inlet Water MPa Turbidity of Inlet Water FTU Parameter Set Parameter Unit Factory Default Actu...

Страница 3: ...quality Depending on the changing of working environment and water requirement each par ameter of filtration should be adjusted accordingly Test water periodically to verify that system is performing...

Страница 4: ...The service days can be set Under the situation of service reaching the setting days and the pressure not yet it could enter into rinsing process when current time is the same as rinsing time 1 3 Ser...

Страница 5: ...Sunshine or rain will cause the system damage Please avoid installing the system in one acid alkaline magnetic or strong vibration circumstance because above factors will cause the system disorder Do...

Страница 6: ...press the manual button to switch thevalve from the filter status to the backwash status c In the unlocked filter status press the manual button to switch the valve from service status to waste status...

Страница 7: ...s b Recirculation indicator lights on and the other indicators light off c Switch from other status to the recirculation status the four digitals of nixie tube display the D1 interface when the motor...

Страница 8: ...ess then finish adjustment then press to turn back S1 S2 S3 S4 S5 S6 Rinsing Time 1 In the program inquiry mode press or to select the rinse time inquiry as Figure S5 shows and 3 10 is displayed Press...

Страница 9: ...ent to pressing the manual button The wiring is as below Figure 3 2 Figure 3 1 GND DC 5 2 Figure 3 2 Wiring of Remote Handling Connector 14 15 MODEL 53524 F139 51524 F139S MODEL 53524 F139 51524 F139S...

Страница 10: ...n be observed from the transparent joint of the drain It will take 8 10 minutes to finish the whole process B Press turning the position from Backwash to Rinse It will take 10 15 minutes to finish the...

Страница 11: ...ing board breaks down B The controller is damaged C Foreign material stuck the driving gear A Check and repair valve body or replace it B Turn off bypass valve and restart when power on A Assure perma...

Страница 12: ...8 39 40 41 Item NO Description Part No Quan tity Quan tity Part No Description Item NO O ring 145 5 7 O ring 50 47 2 62 O ring 47 7 3 55 Valve body Chinese standard Valve body US standard Cable gland...

Страница 13: ...struction 3 Damage resulting from repairing not by the appointed maintenance personnel 4 Content in guarantee proof is unconfirmed with the label on the real good or be altered 5 Damage resulting from...

Отзывы: