Operation & Maintenance

m

a i n t e n a n c e

  &  c

l e a n i n g

Your Runtal Electric Wall Panel (EWP) has been designed to require the absolute minimum maintenance and 
care under normal use. However, care should be taken when cleaning the surface of the panel. Periodically 
vacuum across the top of the grille to remove dust from the grille. A slight odor may be noticeable during 
initial operation and will dissipate within a few hours.

The EWP’s powder coated finish provides an elegant yet durable finish to a welded steel product.  
Occasional cleaning of this finish is best done with a water dampened cloth. 

Under no circumstances should 

abrasive cleaner be used. Before cleaning make sure the power has been turned off at the circuit breaker 
panel, and the heating element is cool.

 Be sure to restore power when cleaning and maintenance is complete.  

All other servicing should be performed by qualified service personnel. 

For installation of multiple electric wall panel radiators, the following chart should be used.  
The chart indicates supply voltage, circuit breaker rating, minimum wire size, and maximum total  
wattage of electric radiators on the circuit.

m

a x i m u m

 W

at tag e

 

o n

 

a

  c

i R c u i t

 

Voltage A.C. 

Circuit Breaker Size 

Maximum Wattage Minimum 

 

 

 

 

 

Wire Size

 

120 

15 Amp 

1440 

14/2 with Ground

 

120 

20 Amp 

1920 

12/2 with Ground

 

120 

30 Amp 

2880 

10/2 with Ground

 

208 

15 Amp 

2496 

14/2 with Ground

 

208 

20 Amp 

3328 

12/2 with Ground

 

208 

30 Amp 

4992 

10/2 with Ground

 

240 

15 Amp 

2880 

14/2 with Ground

 

240 

20 Amp 

3840 

12/2 with Ground

 

240 

30 Amp 

5760 

10/2 with Ground

IMPORTANT INSTRUCTIONS   READ & SAVE THESE INSTRUCTIONS

6

Содержание EWP series

Страница 1: ...hing device thermostat relay switch etc 3 The heating element and high limit thermostat should not be tampered with 4 Individual thermostats used in conjunction with the EWP will determine operational...

Страница 2: ...e wall brackets should be 14 plus the floor clearance distance Example If you would like to have 2 clearance from the floor the top of the K12 mounting bracket should be on the wall 16 above the floor...

Страница 3: ...d is not supplied with the Runtal Electric Wall Panel Note Thermostat location recommendations Locate the thermostat away from the heater and other appliances that give off heat Locate the thermostat...

Страница 4: ...th America Inc US Tel 800 526 2621 s Canadian Tel 888 829 4901 s www runtalnorthamerica com 4 Step 5 Attach the Electrical Supply to the Unit Remove the flat square cover from the junction box and dis...

Страница 5: ...unction box and connected to the appropriate connections locat ed in the junction box Use wire nuts to connect the green wire to the green grounding wire in the junc tion box and one of the heater wir...

Страница 6: ...d Before cleaning make sure the power has been turned off at the circuit breaker panel and the heating element is cool Be sure to restore power when cleaning and maintenance is complete All other serv...

Страница 7: ...th the EWP or any of its components 6 Use heater only as described in this manual Any other use not recommended by the manufacturer may cause fire electric shock or injury to persons 7 Extreme caution...

Отзывы: