11
DISPLAY KEYS DESCRIPTION
RUNPOMETER RM35 DESCRIPTION/ACCESSORIES
TECHNICAL SPECIFICATIONS
REQUIREMENTS FOR THE MEASURED MATERIAL
CONFORMITY ASSESSMENT
The RUNPOMETER RM35 complies with the requirements of the Measuring
Instruments Directive MID 2014/32/EU (conformity assessment procedure
with type test according to module B).
EU type examination certificate number A 0445/2020-0.752.468/2021
x
x
1
Button for opening
2
Cable inlet or cable outlet opening
3
1.5" LCD display
4
USB-C charger socket
5
Index mark – Start/end point for measurement
6
Tempered measuring wheel
7
Guide jaws for precise measurement (2 x 6/24 mm + 2 x 12/18 mm)
8
Bolt for mounting on mounting plate system case or for fastening a
belt with a clip system and anchor pad
9
RUNPOTEC system case with RUNPOMETER RM35 case insert
10
Anchor pad
11
Longitudinally adjustable belt with clip system
12
Mounting plate for fixing on the RUNPOTEC system case
13
Power adapter with USB-C charger cable
A
Menu settings
B
Set a plus value
C
Set a minus value
D
Reset measured values
E
∑ Total 1 – (added measured values) = display TOTAL 1
F
∑ Total 2 – (added measured values) = display TOTAL 2
G
Current measured value / counter value (positive/negative)
H
Actual – counts up to the preset countdown value
I
Countdown (adjustable)
J
Pulling direction display
K
Meter / Feet – displays the set unit
L
Display backlighting on/off
M
Audible signal on/off
N
Battery state of charge
Display unit
Meters (optionally feet)
Max. length.
99999.99 m / 99999.99 ft
Smallest display value
0.01 m
Cable cross-section
min. 2 mm / max. 32 mm
Max. speed.
1 m/s
Measuring wheel diameter
25 mm
Measuring accuracy
Accuracy class III - > 10 m ± 1 %
Measurable length
min. 5 m
Intended location
open
Ambient conditions
Temperature:
Air humidity:
Mechanical:
Electromagnetic:
-10 °C to +40 °C
no condensation
Class M2
Class E1
Protection class
IP 44
Round cross-section
Smooth surface
No kinks
Does not elongate or crush
Dry and unsoiled
x