Operation
Runco LS-3/LS-5 Installation/Operation Manual
53
PRE
L
IMINAR
Y
DLP Frame Rate:
Select DLP Frame Rate from the Advanced menu to choose the
output frame rate. You can have the LS-3/LS-5 automatically determine the optimum
frame rate, or you can force it to use a specific frame rate.
• The default setting,
Auto
, frame locks to the main source if it has a vertical refresh rate
of between 48 and 62Hz. Vertical refresh rates of from 24 to 31Hz are doubled. Frame
rates between 31 and 48Hz and greater than 62Hz are converted to 60Hz.
• Select
48Hz
to force the output frame rate to 48Hz. Use this setting to eliminate 2:3
pull-down judder with 60Hz film-based sources.
•
50Hz
and
60Hz
force the output frame rate to 50Hz and 60Hz respectively.
Color Gamut:
Select Color Gamut from the Advanced menu to select a color gamut
(range) that may be different from the default color gamut.
Each setting defines the precise hue of each primary (red, green and blue) and secondary
(yellow, cyan and magenta) color component used to generate the millions of colors
produced in displays. Changing either or both of these numbers changes the hue of the
color and relocates the “triangle” for possible colors. For example, changing the x/y
coordinates for red moves the color closer to either orange or violet, which in turn affects
all displayed colors having a red component.
•
Auto
automatically chooses the appropriate color gamut:
•
SMPTE C
for NTSC, 480i and 480p sources.
•
EBU
for PAL, SECAM, 576i and 576p sources.
•
REC709
for all other sources.
•
REC709
chooses the REC709 color gamut.
• Select
SMPTE-C
to choose the SMPTE-C color gamut.
• Select
EBU
to choose the EBU color gamut.
• Select
Native
to use REC709 for cyan, magenta, and yellow and uncorrected values
for red, green, and blue.
Table 4-3 lists the x- and y-coordinates for each primary and secondary color component.
If PIP is active, the LS-3/LS-5 converts the PIP source frame rate to
the same frame rate as the main source.
Table 4-3. x/y Color Gamut Values
Primary
Color
Color Gamut Settings and Associated x/y Values
REC709
SMPTE “C”
EBU
x
y
x
y
x
y
Red
0.640
0.330
0.635
0.340
0.640
0.330
Yellow
0.419
0.505
0.421
0.506
0.418
0.502
Green
0.300
0.600
0.305
0.595
0.290
0.600
Cyan
0.225
0.329
0.228
0.326
0.220
0.329
Blue
0.150
0.060
0.155
0.070
0.150
0.060
Magenta
0.321
0.154
0.318
0.162
0.328
0.158
Note
Содержание LightStyle LS-3
Страница 2: ......
Страница 10: ...x Runco LS 3 LS 5 Installation Operation Manual P R E L I M I N A R Y Notes...
Страница 14: ...Table of Contents xiv Runco LS 3 LS 5 Installation Operation Manual P R E L I M I N A R Y Notes...
Страница 16: ...List of Figures xvi Runco LS 3 LS 5 Installation Operation Manual P R E L I M I N A R Y Notes...
Страница 86: ...Maintenance and Troubleshooting 70 Runco LS 3 LS 5 Installation Operation Manual P R E L I M I N A R Y Notes...
Страница 105: ......
Страница 106: ...Runco International 800 23RUNCO Fax 503 748 8161 www runco com 020 1033 00 Rev A November 2009...