Ruijie RG-RAP1200 Series Скачать руководство пользователя страница 8

·

 

Hardware Installation and Reference Guide                                                                                          Preparing for Installation 

 

 

 

Be sure to make a careful check before you shut down the power supply.   

 

Do not place the device in a damp/wet location. Do not let any liquid enter the chassis   

 

Keep the AP far away from the grounding or lightning protection devices of power equipment.   

 

Keep the AP away from radio stations, radar stations, high-frequency high-current devices, and microwave ovens. 

 

Any nonstandard and inaccurate electrical operation can cause an accident such as fire or electric shock, thus 

causing severe even fatal damages to human bodies and device. 

 

Direct or indirect touch through a wet object on high voltage and power line can bring a fatal danger. 

2.4  Ventilation 

For proper ventilation, leave sufficient space around the AP. 

2.5  Temperature and Humidity 

To ensure normal operation and service life of the device, maintain appropriate temperature and humidity levels in your 

equipment room. See Table 2-1. Improper room temperature and humidity can cause damages to the device.   

 

High relative humidity may affect insulation materials, resulting in poor insulation and even electrical leakage, and 

sometimes may lead to change of mechanical properties of materials and corrosion of metal parts.       

 

Low relative humidity may dry and shrink insulation sheets and cause static electricity that can damage the circuitry 

inside the device.   

 

High temperature greatly reduces reliability of the device and shortens its service life. 

Table 2-1 Required Temperature and Humidity for the RG-RAP1200 

Temperature 

Relative Humidity 

0

º

C to 40

º

C (32

º

F to 104

º

F) 

5% to 95% 

2.6  Cleanness 

Dust poses a serious threat to device operation. Dust that falls onto the surface of the device can be absorbed onto metal 

contact points by static electricity, resulting in poor contact. Electrostatic absorption of dust occurs more easily when the 

relative humidity is low, which may shorten the service life of the device and cause communication failures. Table 2-2 

shows the maximum concentration and diameter of dust allowed in the equipment room.   

Table 2-2   

Maximum diameter (

μm) 

0.5   

1   

3   

5   

Maximum concentration 

(Particles/m

3

1.4 x 10

7

 

7 x 10

5

 

2.4 x 10

5

 

1.3 x 10

5

 

Besides, the contents of salts, acids and sulfides in the air are also strictly limited for the equipment room. These 

substances can accelerate metal corrosion and the aging of some parts. Table 2-3 describes the limit of some hazardous 

gases such as SO

2

, H

2

S, NO

2

 and Cl

in the equipment room.       

Содержание RG-RAP1200 Series

Страница 1: ...Ruijie RG RAP1200 F Series Access Points Hardware Installation and Reference Guide 1 00...

Страница 2: ...or by any means without the prior written consent of Ruijie Networks is prohibited Exemption statement This document is provided as is The contents of this document are subject to change without any n...

Страница 3: ...ty https community ruijienetworks com Technical Support Email service_rj ruijienetworks com Skype service_rj ruijienetworks com Related Documents Documents Description Configuration Guide Describes ne...

Страница 4: ...g n 2 4 GHz to 2 4835 GHz 802 11a n ac 5G 5 15 GHz to 5 35 GHz 5 47 GHz to 5 725 GHz 5 725 GHz to 5 850 GHz Country specific Antenna PCB built in antenna Spatial Streams 2 4GHz 2 streams 2x2 MIMO 5GHz...

Страница 5: ...o 70 C 40 F to 158 F Humidity Operating 5 to 95 RH non condensing Storage 5 to 95 RH non condensing Installation Ceiling wall mount in a 86 type faceplate IP Rating IP41 Safety Standards GB4943 EN IEC...

Страница 6: ...is not receiving power Solid blue N A Normal operation Blinking 0 5Hz Normal operation but the AP is not connected to Ruijie Cloud Fast blinking 10Hz Possible cases 1 Restoring the factory default se...

Страница 7: ...ot subject the AP to unstable voltage vibration and noises Keep the installation site dry Installing the device near sea is not recommended Keep the AP at least 500 meters away from the seaside and do...

Страница 8: ...al leakage and sometimes may lead to change of mechanical properties of materials and corrosion of metal parts Low relative humidity may dry and shrink insulation sheets and cause static electricity t...

Страница 9: ...ping pliers punch down tool Meter Multimeter bit error rate tester BERT The listed tools are customer supplied 2 8 Unpacking the Access Point Package Contents Items Verify that all parts are installed...

Страница 10: ...and humidity requirements The installation site is equipped with a proper power supply Network cables are in place The installation site meets all described requirements The custom AP meets customer...

Страница 11: ...asten the device tightly 3 4 Installing the Access Point 1 Loosen screws on the 86 type faceplate that is mounted on the wall Figure 3 1 Loosen Screws on the Faceplate 2 Connect the Ethernet cable to...

Страница 12: ...bending the cable in a small radius close to the connector Ruijie recommends that you do not use Ethernet cables with protective sleeves as they could make installation of Ethernet cables more diffic...

Страница 13: ...or the cabinet After installation make sure that the front and rear cabinet doors easily close Make sure the cabinet is stable and level Make sure the device and all cables are securely fastened in th...

Страница 14: ...iant And then verify that the cable is connected properly Orange LED blinks after the Ethernet cable is connected Verify that the device at the other end of the Ethernet cable is working properly And...

Страница 15: ...Hardware Installation and Reference Guide Troubleshooting 3 Adjust the transmit power 4 Move the client device to adjust the distance between the client and the AP...

Страница 16: ...imum distance of 100 meters 328 feet 1000BASE T requires all four pairs of wires be connected for data transmission as shown in Figure A 1 Figure A 1 1000BASE T Connection 10BASE T uses Category 3 4 5...

Страница 17: ...the bend radius should be 10 times the overall diameter The minimum bend radius of a high speed cable such as an SFP cable should be 5 times the overall diameter of the cable If the cable is constantl...

Страница 18: ...ation is not affected and no damages occur to the device and cables during debugging Do not bind power cords to the rails for moving parts Leave a certain length of the cable connecting moving parts s...

Страница 19: ...to fasten terminals Bundle cables of the same type and running in the same direction into groups Keep cables clean and straight Cables shall be tied according to the following table Diameter of Cable...

Отзывы: