Hardware Installation and Reference Guide Installing the Access Point
Disconnect the device before cleaning it.
Do not wipe the device with a damp cloth.
Do not wash the device with liquid.
Do not open the enclosure when the AP is working.
Fasten the device tightly.
3.4 Installing the Access Point
Ceiling Mount
1. Drill four 6 mm (0.24 in.) diameter holes in the ceiling, 53 mm (2.09 in.) apart. Tap wall anchors into the holes, and
drive screws through the mounting bracket into the anchors to secure the bracket, as shown in Figure 3-1.
Figure 3-1 Attaching the Mounting Bracket to the Ceiling
2.
Align the square feet (on the rear of the AP) over the mounting holes on the bracket. See Figure 3-2.
Figure 3-2 Aligning the Square Feet with the Mounting Holes
Install the Ethernet cables before mounting the AP on the bracket.
3.
Slide the AP onto the bracket in the opposite direction of the arrow on the mounting bracket until it clicks into place,
as shown in Figure 3-3.