RDC7132G User manual V1.0
SHENZHEN RUIDA TECHNOLOGY
27
Anchor 1-4 enablement: when multiple anchor logic is enabled, four anchor points
can be individually disabled and enabled.
Once you select the setpoint logic, assuming that the next anchor point
number is 1, and four anchor point all can make, is when to start the memory
file (including keyboard start and PC start), or PC using direct output to start the
work and choose the options "to the original site for the anchor point," every
time start work will adopt different anchor point, anchor point rotation order 1
- > 2 - > 3 - > 4-1 - > 2 >... cars only If PC starts working with direct output and
selects "current point as anchor point", the system will always use the current
point as anchor point.
4.3.6
Set as the factory parameter
Press ok when the light blue cursor is over the item, and the following dialog box pops up
:
Press the "X + / -" and "Y + / -" keys to choose characters, when the cursor to input password
characters according to the "ok" button to select the characters, and then the password column will
display the corresponding to the characters, enter the 6 characters, if the wrong password prompt "wrong
password", to choose a password, if the password is correct, system will send all current manufacturer
parameters and user parameter is set to the factory, screen tips "success", set up the factory parameters.
When the machine leaves the factory, use the function of "set as
factory parameters" to backup all the debugging factory parameters and
user parameters, and then at any time, "restore factory parameters" can
be used to restore all manufacturer and user parameters
.
4.3-6