The RSG2100P can be equipped with either a Philips Screw Terminal Block or a Phoenix Plug 
Terminal Block. The Philips Screw Terminal Block has Philips screws with a compression plate 

allowing either bare wire connections or crimped terminal lugs. We recommend the use of #6 size 
ring lugs to ensure secure, reliable connections under severe shock or vibration. Both terminal 

blocks have a safety cover which must be removed via two Phillips screws before connecting any 
wires.  The safety cover must be re-attached after wiring to ensure personnel safety.

 

Refer to Table 

3 below for a description of each terminal as well as sections 4.2.1 through 4.2.2 for wiring 
examples.

 

 

Terminal # 

Description 

Usage 

PS1 Live / + 

PS1 Live / +

 is connected to the positive (+) terminal if the 

power source is DC or to the (Live) terminal if the power 

source is AC. 

PS1 Surge Ground 

PS1 Surge Ground

 is connected to the Chassis Ground via 

a jumper on the terminal block. Surge Ground is used as the 

ground conductor for all surge and transient suppression 
circuitry.  

PS1 Neutral / - 

PS1 Neutral / - 

is connected to the negative (-) terminal if 

the power source is DC or to the (Neutral) terminal if the 
power source is AC. 

4 Chassis 

Ground 

Chassis Ground

 is connected to the Safety Ground 

terminal for AC inputs or the equipment ground bus for DC 

inputs. Chassis ground connects to both power supply surge 
grounds via a removable jumper.

 

5 PS2 

PS2 +

 is connected to the positive (+) terminal of the 48VDC 

power supply. 

PS2 Surge Ground 

PS2 Surge Ground

 is connected to the Chassis Ground via 

a jumper on the terminal block. Surge Ground is used as the 
ground conductor for all surge and transient suppression 

circuitry.  

7 PS2 

PS2 - 

is connected to the negative (-) terminal of the 48VDC 

power supply. 

Relay NO Contact 

Normally open, failsafe relay contact. 

Relay Common 

Failsafe relay common contact. 

10 

Relay NC Contact 

Normally closed, failsafe relay contact. 

Table 3: RSG2100P Series Power terminal block connection description 
 

14 

©

 

2008 RuggedCom Inc.  All rights reserved 

 

Rev105

 

Содержание RuggedSwitch RSG2100P

Страница 1: ...ar Power over Ethernet Managed Ethernet Switch Installation Guide August 14 2008 www ruggedcom com RuggedCom Inc I 30 Whitmore Road Woodbridge Ontario Canada L4L 7Z4 Tel 905 856 5288 I Fax 905 856 199...

Страница 2: ...dures other than those specified herein may result in hazardous radiation exposure This product contains no user serviceable parts Attempted service by unauthorized personnel shall render all warranti...

Страница 3: ...1 1 20 Data Ports 5 1 2 21 Data and Power Ports 5 1 3 21 Transient Suppression 5 2 22 Fiber Optic Ports 5 2 1 24 Gigabit Ethernet 1000Base Tx Cabling Recommendations 5 2 2 25 Pluggable optics Install...

Страница 4: ...MTRJ connector 22 Figure 18 100FX 1000LX LC connector 22 Figure 19 100FX 1000LX SC connector 22 Figure 20 100FX 1000LX ST connector 23 Figure 21 1000LX GBIC Module and 23 Figure 22 1000LX SFP mini GBI...

Страница 5: ...t optical specifications 31 Table 14 Gigabit Ethernet optical specifications 32 Table 15 Test Type Specifications 34 Table 16 Operating Environment 34 Table 17 Mechanical Specifications 35 Table 18 Ag...

Страница 6: ...0P is highly versatile and can support multiple fiber types and connectors ST MTRJ LC SC without loss of port density The RSG2100P is an ideal solution to power and connect several Ethernet devices su...

Страница 7: ...optional 18 AWG galvanized steel enclosure Rugged Operating System ROSTM Features All the same features as the RSG2100 Enhanced Rapid Spanning Tree eRSTP Quality of Service 802 1p for real time traffi...

Страница 8: ...veying Link Activity Duplex or Speed via push button control System reset via push button if held for 5 seconds Figure 1 RSG2000 Series LED Display Panel Device status LEDs exist to provide a quick vi...

Страница 9: ...urs and the corresponding description Mode Colour Description Green Solid Link Green Blinking Activity Status Off No link Green Solid Full Duplex operation Orange Solid Half Duplex operation Duplex Of...

Страница 10: ...y onto a panel For rack mount installations the RSG2000 series can be ordered with connectors on the front of the unit or located on the rear of the chassis to allow for all data and power cabling to...

Страница 11: ...19 rack An additional two rack mount adapters are included to optionally secure the rear of the chassis in high vibration or seismically active locations NOTE Since heat within the RSG2100P is channe...

Страница 12: ...rs to be mounted on each side of the chassis enclosure The adapter allows for the chassis to be mounted on the standard 1 DIN rail using the grooves in the adapter secured using the included philips s...

Страница 13: ...is Ground Jumper The RSG2100P supports a single AC or DC power supply Power Supply 1 PS1 and a separate 48VDC power supply Power Supply 2 PS2 used to provide the power over Ethernet The connections fo...

Страница 14: ...umper on the terminal block Surge Ground is used as the ground conductor for all surge and transient suppression circuitry 3 PS1 Neutral PS1 Neutral is connected to the negative terminal if the power...

Страница 15: ...C PS2 power supply wiring examples NOTES 1 100 240VAC rated equipment A 250VAC appropriately rated circuit breaker must be installed 2 Equipment must be installed according to the applicable country w...

Страница 16: ...TES 1 88 300VDC rated equipment A 300VDC appropriately rated circuit breaker must be installed 2 A circuit breaker is not required for 12 24 or 48 VDC rated power supplies 3 Equipment must be installe...

Страница 17: ...l block This metal jumper connects transient suppression circuitry to chassis ground and must be removed in order to avoid damage to transient suppression circuitry during HIPOT testing Figure 11 show...

Страница 18: ...and remain energized until a critical error occurs The proper relay connections are shown in Figure 12 Control of the output is user selectable and can be programmed via the Rugged Operating System R...

Страница 19: ...le cable For user reference the console cable pin out is show in Table 5 RuggedCom RS232 over RJ45 pin out specification Signal Name PC is DTE DB9 Female RJ45 Male DCD Carrier detect 1 2 RxD Receive d...

Страница 20: ...1 RJ45 Twisted Pair Ports 5 1 1 Data Ports The RSG2100P may have several 10 100BaseTX ports that allow connection to standard CAT 5 UTP cable with RJ45 male connectors All RSG2000 series RJ45 RuggedSw...

Страница 21: ...Table 6 RJ45 PoE pin out assignment 5 1 3 Transient Suppression RuggedCom does not recommend the use of copper cabling of any length for critical real time substation automation applications However...

Страница 22: ...Modules located on the bottom row of the device have locking mechanisms or tabs towards the bottom of the device The drawings in the following figures show each fiber optical connector style with a s...

Страница 23: ...Figure 21 100FX 1000LX ST connector Figure 22 1000LX GBIC Module and SC connector Figure 23 1000LX SFP mini GBIC Module and LC connector 23 2008 RuggedCom Inc All rights reserved Rev105...

Страница 24: ...ure required 5 Yes Verify TIA EIA 568 A compliance 5e Yes No action required New installations should be designed with Category 5e components or higher 6 Yes No action required 6 Yes Connector and cab...

Страница 25: ...into a chassis 3 SFP and GBIC optical modules should always be stored in an ESD safe bag or other suitable ESD safe environment free from moisture and stored at proper storage temperature 40 to 85 C...

Страница 26: ...latch location on GBIC optical modules 5 2 2 3 SFP Module Removal SFP Modules are removed using the metal bail latch located on the top of the module shown in Figure 26 To remove the SFP module disco...

Страница 27: ...DC 72 VDC 2A T 2 68 W Table 9 PoE Power Supply Specifications NOTES 1 This is the same power supply for both AC and DC 2 F Denotes fast acting fuse T denotes time delay fuse 3 Power consumption varies...

Страница 28: ...TX 100BaseFX IEEE 802 3z 9 1000BaseSX LX IEEE 802 3ab 9 1000BaseTx IEEE 802 3x 9 9 9 Full Duplex Operation IEEE 802 1D 9 9 9 MAC Bridges IEEE 802 1Q 9 9 9 VLAN Virtual LAN IEEE 802 1p 9 9 9 Priority L...

Страница 29: ...ng Cable Type Category 5 Shielded Unshielded Wiring Standard TIA EIA T568A B Auto Crossover Auto polarity Max Distance 100 m Connector RJ45 Isolation 1 5 kV RMS 1 minute PoE Voltage 44 57 V PoE Ports...

Страница 30: ...the type of optics at time of ordering and can determine the modules installed on a particular unit by reading the factory data file via the RuggedSwitch ROSTM user interface The following sections de...

Страница 31: ...8 34 11 2 2 14 2 12 11 0012 10FL SM ST 1310 9 125 27 14 35 3 5 8 12 11 0007 100FX MM ST 1300 62 5 125 19 14 33 9 14 2 14 9 50 125 22 5 14 33 9 14 2 11 4 12 11 0009 100FX MM SC 1300 50 125 22 5 14 33...

Страница 32: ...10 11 5 12 11 0028 1000LX SM LC 1310 9 125 5 0 24 3 25 19 12 11 0025 1000LX SM SC 1310 9 125 10 3 20 3 10 10 12 11 0026 1000LX SM SC 1310 9 125 5 0 20 3 25 15 25 10 0111 1000SX MM LC 850 62 5 125 9 2...

Страница 33: ...egment distances 2 All cabling is duplex type unless otherwise specified 3 All optical power numbers are listed as dBm averages 4 These transceivers utilize a distributed feedback DFB type laser and a...

Страница 34: ...EC 61000 4 3 ANSI IEEE Radiated RFI Immunity 35 V m ANSI IEEE C37 90 2 ESD Electrostatic Discharge 15 kV air discharge 8 kV contact IEC 61000 4 2 Level 4 Atmospheric Environment Levels Comments Temper...

Страница 35: ...0 17 x 1 74 inches 464 57 x 258 32 x 44 20 mm Length x Width x Height with mounting brackets installed Weight 10 lb 4 5 Kg Enclosure 18awg galvanized steel Table 17 Mechanical Specifications Figure 28...

Страница 36: ...ubchapter J Compliant IEC EN EN60825 1 1994 A11 1996 A2 2001 Compliant Table 18 Agency Approvals 8 Warranty RuggedCom warrants this product for a period of five 5 years from date of purchase For warra...

Отзывы: