4.6 Fiber Optic Ethernet Port Specifications
Speed
Standard
Mode /
Connector
Tx
λ
λλ
λ
(nm)
Cable
Type
2
(
µ
µ
µ
µ
m)
Tx Pwr
(dBm peak)
3
(Min / Max)
Rx
Sensitivity
(dBm Average)
3
Rx Saturation
(dBm Peak)
3
Typical
Distance
(km)
1
Power
Budget
(dB)
100Base-FX
MM / ST
1310
50/125
-15.7
-33.5
-11
2
17
100Base-FX
MM / SC
1310
50/125
-16/-11
-33
-11
2
17
100Base-FX
MM / LC
1310
50/125
-19 / -14
-32
-14
2
15
100Base-FX
MM / MTRJ
1310
50/125
-16/-11
-33.5
-11
2
17
100Base-FX
SM / ST
1310
9/125
-15/-8
-32
-7
20
16.5
100Base-FX
SM / SC
1310
9/125
-13/5
-31
-4
20
20
100Base-FX
SM / LC
1310
9/125
-15/-8
-31
-5
15
16.5
Table 13 - Fiber Optic Port Specifications
NOTES:
1.
Maximum segment length is dependent on factors such as fiber quality, and number of patches and splices.
Please consult RuggedCom sales associates when determining maximum segment distances.
2.
To convert from average to peak add 3 dBm. To convert from peak to average, subtract 3 dBm.
4.7 Communication Standards
Protocol
Standards
Ethernet
IEEE 802.3
VDSL
ETSI TS 101 270-2 V1.1.1, ITU-T G.993.1, ANSI T1E1.4
Table 14 - Communication Standard Compliance