background image

RuggedSwitch™ RS900GP

RuggedCom® RuggedSwitch™

5

RS900GP Installation Guide Rev 101

List of Tables

1.1. Front Panel LED Definitions ...............................................................................................  9
2.1. RS232 Female DCE Pinout ..............................................................................................  15
2.2. RJ45 Ethernet Pin Assignment ......................................................................................... 16
3.1.  Operating  Environment  .....................................................................................................   17
3.2. RS900GP Power Supply Specifications ...........................................................................  17
3.3. IEEE802.3AF Power Supply Ratings ................................................................................ 17
3.4. IEEE802.3AT Power Supply Ratings ................................................................................ 17
3.5. Failsafe Relay Specifications ............................................................................................  17
3.6. Twisted Pair Data Port Specifications ............................................................................... 18
3.7. Fiber Optic Port Specifications .........................................................................................  19
3.8.  Physical  Specifications  ......................................................................................................  20
3.9. RS900GP IEC 61850-3 Type Tests .................................................................................  21
3.10. RS900GP IEEE 1613 Type Tests ..................................................................................  22
3.11. IEC Environmental Type Tests .......................................................................................  22
3.12.  Agency  Approvals  ...........................................................................................................   23

Содержание RuggedSwitch RS900GP

Страница 1: ...RuggedSwitch RS900GP Hardware Installation Guide Revision 101 November 1 2012 www RuggedCom com ...

Страница 2: ...OX RuggedBackbone RuggedRated and eRSTP are trademarks of RuggedCom Inc ROS RuggedRouter and RuggedSwitch are registered trademarks of RuggedCom Inc Other designations in this manual might be trademarks whose use by third parties for their own purposes would infringe the rights of the owner Linux is the registered trademark of Linus Torvalds in the U S and other countries The registered trademark ...

Страница 3: ...iring and Grounding 14 2 4 Failsafe Output Wiring and Specifications 15 2 5 RS232 Port Wiring 15 2 6 RJ45 Ports Signal Description 16 3 Specifications 17 3 1 Operating Environment 17 3 2 Power Supply Specifications 17 3 2 1 General 17 3 2 2 IEEE802 3AF 17 3 2 3 IEEE802 3AT 17 3 3 Failsafe Relay Specifications 17 3 4 Twisted Pair Data Port Specifications 18 3 5 Fiber Optic Port Specifications 19 3 ...

Страница 4: ...nel 9 2 1 DIN Rail Mounting 10 2 2 Front Panel Mounting 11 2 3 Rear Panel Mounting 12 2 4 Side Panel Mounting 13 2 5 DC Power Supply Wiring and Grounding 14 2 6 RS900GP Chassis Ground Connection 14 2 7 Failsafe Output Relay 15 2 8 RS232 Female Connector 15 2 9 RJ45 Port Connector 16 3 1 RS900GP Physical Dimensions 20 ...

Страница 5: ...ment 17 3 2 RS900GP Power Supply Specifications 17 3 3 IEEE802 3AF Power Supply Ratings 17 3 4 IEEE802 3AT Power Supply Ratings 17 3 5 Failsafe Relay Specifications 17 3 6 Twisted Pair Data Port Specifications 18 3 7 Fiber Optic Port Specifications 19 3 8 Physical Specifications 20 3 9 RS900GP IEC 61850 3 Type Tests 21 3 10 RS900GP IEEE 1613 Type Tests 22 3 11 IEC Environmental Type Tests 22 3 12 ...

Страница 6: ...ments or performance of procedures other than those specified herein may result in hazardous radiation exposure Caution Service This product contains no user serviceable parts Attempted service by unauthorized personnel shall render all warranties null and void Changes or modifications not expressly approved by RuggedCom Inc could invalidate specifications test results and agency approvals and voi...

Страница 7: ...array of intelligent functionality for high network availability and manageability Ethernet Ports Up to 2 Fiber Optic Gigabit Ethernet Ports 100 1000BaseX 8 Fast Ethernet Ports 10 100BaseTX all external 802 3af 802 3at compliant PoE Up to 2 10 100 1000 BaseTX copper ports Full compliance with IEEE 802 3 802 3u and 802 3z Non blocking store and forward switching Full duplex operation and flow contr...

Страница 8: ... 8192 MAC addresses Auto negotiation on all 10 100BaseTX ports Auto MDI MDIX crossover on all 10 100BaseTX ports LED indicators for Link Activity and Power ROS Advanced Network Management Enhanced Rapid Spanning Tree eRSTPTM Quality of Service 802 1p for real time traffic Port rate limiting 128kbps to 8Mbps VLAN 802 1q with double tagging IGMP Snooping for multicast filtering Port configuration st...

Страница 9: ...eady Power is on Alarm LED Red steady Alarm condition exists Ethernet Port 1 8 Link LED Green steady Network link Ethernet Port 1 8 Link LED Green blinking Network activity Ethernet Port 1 8 PoE LED Orange steady PoE is enabled and powered on Ethernet Port 1 8 PoE LED Orange blinking PoE is enabled and powered off Ethernet Port 1 8 PoE LED Off PoE is disabled Table 1 1 Front Panel LED Definitions ...

Страница 10: ...nstallation RuggedCom RuggedSwitch 10 RS900GP Installation Guide Rev 101 2 Installation 2 1 DIN Rail Mounting An optional DIN rail mounting bracket is available for the RS900GP Figure 2 1 DIN Rail Mounting ...

Страница 11: ...on Guide Rev 101 2 2 Panel Mounting Options The RS900GP can be equipped with front rear or side panel mount brackets 2 2 1 RS900GP Front Panel Mount Option The front panel mounting brackets fit flush with the front of the RS900GP Figure 2 2 Front Panel Mounting ...

Страница 12: ...llation RuggedCom RuggedSwitch 12 RS900GP Installation Guide Rev 101 2 2 2 RS900GP Rear Panel Mount Option The rear panel mounting brackets fit flush with the rear of the RS900GP Figure 2 3 Rear Panel Mounting ...

Страница 13: ...llation RuggedCom RuggedSwitch 13 RS900GP Installation Guide Rev 101 2 2 3 RS900GP Side Panel Mount Option The side panel mounting brackets fit flush with the side of the RS900GP Figure 2 4 Side Panel Mounting ...

Страница 14: ...the DC inputs according to the polarity markings on the unit 1 Equipment must be installed according to the applicable country wiring codes 2 Surge Ground should be connected to Chassis Ground via a braided cable or other appropriate ground wire 3 Chassis Ground must be connected to the protective earth 4 All line to ground transient energy is shunted to the Surge Ground terminal In cases where us...

Страница 15: ...ort Wiring The RS232 port is used for configuring the unit A straight through serial cable with a DB 9 connector is required There is no need to crossover the Transmit and Receive signals from the PC side since this has been done internally as shown in the figure below Figure 2 8 RS232 Female Connector Pin Signal 1 No Connection 2 Transmit Data 3 Receive Data 4 No Connection 5 Ground 6 No Connecti...

Страница 16: ...10 100 1000Base Tx 1 RX A 2 RX A 3 TX B 4 NC C 5 NC C 6 TX B 7 NC D 8 NC D Table 2 2 RJ45 Ethernet Pin Assignment RuggedCom does not recommend the use of CAT 5 cabling of any length for critical real time substation automation applications However transient suppression circuitry is present on all copper ports to protect against damage from electrical transients and to ensure IEC 61850 3 and IEEE 1...

Страница 17: ... Power Supply Type Minimum Input Maximum Input Fuse Rating Isolation RS900GP Maximum Power Consumption Maximum Combined Power Output at PoE Ports 54 VDC 45 VDC 57 VDC 6 3A T a 1 5 kV DC 15W 273W a T denotes time delay fuse Table 3 2 RS900GP Power Supply Specifications 3 2 2 IEEE802 3AF Power In Power Out 45 57 VDC 3 5 A MAX 44 57 VDC 15 W PORT MAX Table 3 3 IEEE802 3AF Power Supply Ratings 3 2 3 I...

Страница 18: ...dCom RuggedSwitch 18 RS900GP Installation Guide Rev 101 3 4 Twisted Pair Data Port Specifications Data Port Media Distance Connector Type 10 100 Mbps Cat 5 UTP or STP 100m RJ45 Table 3 6 Twisted Pair Data Port Specifications ...

Страница 19: ... 25 2SC10 SM SC 1310 9µ 125 10 3 22 3 10 2SC25 SM SC 1310 9µ 125 7 3 24 3 25 SFP MM LC 850 50µ 125 8 5 4 22 3 0 5 SFP SM LC 1310 9µ 125 9 3 24 0 10 SFP SM LC 1310 9µ 125 7 3 26 3 25 SFP d SM LC 1550 9µ 125 5 0 26 0 50 SFP d SM LC 1550 9µ 125 0 5 26 0 80 SFP SM SC Simplex 1310 9µ 125 9 3 22 3 10 SFP d SM SC Simplex 1490 9µ 125 9 3 22 3 10 a All cabling is duplex type unless otherwise specified b Al...

Страница 20: ...3 6 Physical Dimensions Figure 3 1 RS900GP Physical Dimensions Parameter Value Comments Dimensions 6 95 3 63 6 08 inches 17 653 9 22 14 4432 cm Length Width Depth Weight To be determined Ingress Protection IP40 1mm objects Enclosure Cast Aluminum Table 3 8 Physical Specifications ...

Страница 21: ...onducted RFI Earth ground ports 10V 3 IEC 61000 4 8 Magnetic Field Enclosure ports 40 A m continuous 1000 A m for 1 s N A IEC 61000 4 29 Voltage Dips Interrupts D C Power ports 30 for 0 1s 60 for 0 1s 100 for 0 05s N A Signal ports 2 5kV common 1kV differential mode 1MHz 3 IEC 61000 4 12 Damped Oscillatory D C Power ports 2 5kV common 1kV differential mode 1MHz 3 Signal ports 30V Continuous 300V f...

Страница 22: ... AC Failsafe Relay C37 90 6 Dielectric Strength D C Power ports 1 2kV DC Table 3 10 RS900GP IEEE 1613 Type Tests If the unit contains copper ports the IEEE 1613 conformance is Class 1 During disturbance errors may occur but recovery is automatic If the unit contains all fiber ports the IEEE 1613 conformance is Class 2 During disturbance no errors will occur 3 7 3 IEC Environmental Type Tests Test ...

Страница 23: ...mpliance is claimed via Declaration of Self Conformity Route FCC FCC Part 15 Class A Approved CISPR a EN55022 Class A Approved FDA CDRH 21 CFR Chapter 1 Subchapter J Approved IEC EN EN60825 1 1994 A11 1996 A2 2001 Approved CSA Hazardous Locations Class 1 Division 2 Groups A B C D T6 rating at 40 C T4A rating at 85 C Approved a With the use of shielded Ethernet cables Table 3 12 Agency Approvals ...

Страница 24: ...is product contains no user serviceable parts Attempted service by unauthorized personnel shall render all warranties null and void For warranty details visit www RuggedCom com or contact your customer service representative Should this product require service contact the factory at RuggedCom Inc 300 Applewood Crescent Concord Ontario Canada L4K 5C7 Phone 1 905 856 5288 Fax 1 905 856 1995 ...

Отзывы: