5 Technical
Specifications
5.1 Power Supply Specifications
Input Range
Power Supply Type
Min
Max
Fuse
Rating
Max. Power
Consumption
3
12 – 24 VDC
10 VDC
36 VDC
6.3A(F)
2
24 VDC
18 VDC
36 VDC
5A(F)
2
48 VDC
36 VDC
59 VDC
2A(T)
2
HI (125/250 VDC)
1
HI (110/230 VAC)
1
88 VDC
85 VAC
300 VDC
265 VAC
2A(T)
1,2
22W
NOTES:
1.
This is the same power supply for both AC and DC.
2.
(F) Denotes fast-acting fuse, (T) denotes time-delay fuse
3.
Power consumption varies based on configuration. 10/100Tx ports consume roughly 1W
less than fiber optic ports.
4.
For continued protection against risk of fire, replace only with same type and rating of fuse.
5.2 Failsafe Relay Specifications
Parameter
Value (Resistive Load)
Max Switching Voltage
240VAC, 125VDC
Rated Switching Current 2A @ 240VAC
0.15A @ 125VDC, 2A @ 30VDC
Max Switching Capacity 150W, 500VA