RuggedCom RUGGEDPOWER RP100 Скачать руководство пользователя страница 11

2. Installation

RuggedCom® RuggedPower™

11

RP100 Installation Guide Rev101

2.4.2. RuggedMAX Power Port / IEEE802.3at Port

The RuggedMax Power port takes data received on the 10/100 Base TX port and injects power
on pins 4, 5 and 7, 8. CAT-5E STP (shielded twisted pair) cable should be used to connect this
port to the powered device. For RP100 units with the “AT” IEEE802.3at-compliance option, the
unit only delivers power when an IEEE802.3at-compliant powered device is attached.

Figure 2.4. RJ45 Port Pinout

RuggedMax Power

10/100 Base Tx

Pin

Signal

Pin

Signal

1

+Tx

1

+Tx

2

-Tx

2

-Tx

3

+Rx

3

+Rx

4

V+

4

Terminated

5

V+

5

Terminated

6

-Rx

6

-Rx

7

V-

7

Terminated

8

V-

8

Terminated

Case

Shield (Chassis

Ground)

Case

Shield (Chassis

Ground)

Table 2.1. RJ45 Ethernet Port Pinout

The unused pins, 4, 5, 7, and 8 of the 10/100Tx port are terminated to Chassis Ground
via a network that improves EMI and ESD performance.

Содержание RUGGEDPOWER RP100

Страница 1: ...RuggedPower RP100 Hardware Installation Guide Revision 101 April 26 2012 www RuggedCom com ...

Страница 2: ...echnical improvements without notice Registered Trademarks ROX RuggedRated and eRSTP are trademarks of RuggedCom Inc RuggedRouter is a registered trademark of RuggedCom Inc RuggedBackbone is a trademark of RuggedCom Inc Other designations in this manual might be trademarks whose use by third parties for their own purposes would infringe the rights of the owner Linux is the registered trademark of ...

Страница 3: ...Top View 8 1 4 RP100 Side View 8 2 Installation 9 2 1 DIN Rail Mounting 9 2 2 AC Power Supply Wiring and Grounding 9 2 3 DC Power Supply Wiring and Grounding 10 2 4 RJ45 Ports Signal Description 10 2 4 1 10 100 TX Port 10 2 4 2 RuggedMAX Power Port IEEE802 3at Port 11 3 Specifications 12 3 1 Power Supply Specifications 12 3 2 Mechanical Specifications 12 3 3 Physical Dimensions 13 A Warranty 14 ...

Страница 4: ...uide Rev101 List of Figures 1 1 RP100 Front Panel 7 1 2 RP100 Top View 8 1 3 RP100 Side View 8 2 1 RP100 DIN Rail Mounting 9 2 2 AC Power Supply and Ground Connections 9 2 3 DC Power Supply and Ground Connections 10 2 4 RJ45 Port Pinout 11 3 1 RP100 Dimensions 13 ...

Страница 5: ...wer RP100 RuggedCom RuggedPower 5 RP100 Installation Guide Rev101 List of Tables 1 1 RP100 Front Panel LED 7 2 1 RJ45 Ethernet Port Pinout 11 3 1 Power Supply Specifications 12 3 2 Mechanical Specifications 12 ...

Страница 6: ...void the user s authority to operate the equipment Should this device require service refer to Appendix A Warranty in this guide Caution Physical Access This product should be installed in a restricted access location where access can only be gained by service personnel or users who have been instructed about the reasons for the restrictions applied to the location and about any precautions that s...

Страница 7: ... option the RP100 operates on DC power in the range of 10 VDC to 60 VDC and can deliver power up to 36 W HI power supply option the RP100 operates on AC power in the range of 90 VAC to 264 VAC or on DC power in the range of 88 VDC to 300 VDC and can deliver power up to 25 W The RP100 can be ordered with one of two application options RM option the RP100 is intended for RuggedMax WiMax devices only...

Страница 8: ...1 Product Overview RuggedCom RuggedPower 8 RP100 Installation Guide Rev101 1 3 RP100 Top View Figure 1 2 RP100 Top View 1 4 RP100 Side View Figure 1 3 RP100 Side View ...

Страница 9: ...il Mounting details the mounting configuration for a standard 1 DIN rail Figure 2 1 RP100 DIN Rail Mounting 2 2 AC Power Supply Wiring and Grounding This section applies only to RP100 units equipped with the HI power supply option Figure 2 2 AC Power Supply and Ground Connections Connect the AC power supply as follows 1 L AC HOT and is connected to the HOT terminal of the AC power source ...

Страница 10: ...C power source 3 Ground must be connected to the Safety Ground via a braided cable or other appropriate grounding wire 4 Safety Ground should be connected to the power supply ground or equipment ground bus Ground must be disconnected from Chassis Ground during HIPOT Dielectric strength testing 2 4 RJ45 Ports Signal Description 2 4 1 10 100 TX Port 10 100Base TX ports allow connection to standard C...

Страница 11: ...with the AT IEEE802 3at compliance option the unit only delivers power when an IEEE802 3at compliant powered device is attached Figure 2 4 RJ45 Port Pinout RuggedMax Power 10 100 Base Tx Pin Signal Pin Signal 1 Tx 1 Tx 2 Tx 2 Tx 3 Rx 3 Rx 4 V 4 Terminated 5 V 5 Terminated 6 Rx 6 Rx 7 V 7 Terminated 8 V 8 Terminated Case Shield Chassis Ground Case Shield Chassis Ground Table 2 1 RJ45 Ethernet Port ...

Страница 12: ... 3 5 A 52 VDC POE 25 W 85 C 24 VDC 2 A RP100 LO AT XX 48 VDC 1 A 52 VDC POE 32 W 85 C 100 240 V 50 60 Hz RP100 HI RM XX 125 250 VDC 700 mA 52 VDC POE 25 W 85 C 100 240 V 50 60 Hz RP100 HI AT XX 125 250 VDC 700 mA 52 VDC POE 25 W 85 C Table 3 1 Power Supply Specifications 3 2 Mechanical Specifications Specification Value Dimensions Length Width Depth 4 625 2 225 3 75 inches 117 57 95 mm Weight 1 92...

Страница 13: ...3 Specifications RuggedCom RuggedPower 13 RP100 Installation Guide Rev101 3 3 Physical Dimensions Figure 3 1 RP100 Dimensions ...

Страница 14: ... product contains no user serviceable parts Attempted service by unauthorized personnel shall render all warranties null and void For warranty details visit www RuggedCom com or contact your customer service representative Should this product require service contact the factory at RuggedCom Inc 300 Applewood Crescent Concord Ontario Canada L4K 5C7 Phone 1 905 856 5288 Fax 1 905 856 1995 ...

Отзывы: