background image

RuggedMAX™

WiN7200 Small Form

Factor Base Station

Installation Guide

Version 1.0 - June 18, 2012

Содержание RuggedMAX WiN7200

Страница 1: ...RuggedMAX WiN7200 Small Form Factor Base Station Installation Guide Version 1 0 June 18 2012...

Страница 2: ...ments We reserve the right to make technical improvements without notice Registered Trademarks ROX RuggedRated eRSTP RuggedBackbone and RuggedMAX are trademarks of RuggedCom Inc RuggedRouter is a regi...

Страница 3: ...5 3 1 1 Criteria for Outdoor Locations 15 3 1 2 Criteria for Indoor Locations 15 3 1 3 External GPS Antenna Installation Location 15 3 1 4 Antenna Grounding Requirements 15 4 Installation Procedures 1...

Страница 4: ...rm Factor Base Station RuggedMAX 4 Installation Guide Rev 1 0 C IDU to ODU Cable Specifications 34 D Console Connector Specifications 36 E WiN7200 Small Form Factor Base Station Base Station Mechanica...

Страница 5: ...e plug housing 19 4 7 Securing the plug housing 19 4 8 PoE connector secured to base station 20 4 9 Wall Mounting Bracket 20 4 10 Attaching the Mounting Bracket 21 4 11 Base Station and Wall Mounting...

Страница 6: ...l Form Factor Base Station Interface Connectors 13 4 1 ODU IF Port Pinout 18 4 2 Data Adaptor LED Indicators 25 A 1 List of Acronyms 31 C 1 IDU to ODU Cable Description 34 C 2 IDU to ODU Cable Design...

Страница 7: ...in which case the user will be required to correct the interference at his own expense Caution Service This product contains no user serviceable parts Attempted service by unauthorized personnel shall...

Страница 8: ...he Canadian Electrical Code CEC Part 1 CSA C22 1 and when applicable the National Electrical Safety Code IEEE C2 Unless marked or otherwise identified the Standard for the Protection of Electronic Com...

Страница 9: ...u may be exposed to hazardous environments and high voltage Use caution when installing the outdoor system 1 1 7 Antenna Grounding Requirements Verify that the antenna or cable system is grounded eart...

Страница 10: ...1 About This Guide RuggedMAX 10 Installation Guide Rev 1 0 To reduce the risk of fire only use a No 24AWG or larger telecommunication line cord between the indoor and outdoor units...

Страница 11: ...stallable by one person is powered by Power over Ethernet PoE and supports remote management The WiN7200 Small Form Factor Base Station is supported by RuggedCom s RuggedNMS Network Management System...

Страница 12: ...d and mobile CPE support 3 5 MHz 5MHz 7MHz and 10MHz channel bandwidth support Different RF options including 2 x 3 x GHz band support Traffic classification and connection establishment initiation Po...

Страница 13: ...panel connectors and ports Connector Name Connector Type Cable Type Function Connected to ANT1 N typeFemale RG 214 U RF antenna connection External antenna or screwed on omni directional antenna CONS...

Страница 14: ...ternal GPS antenna can be connected to the bottom panel GPS connector See Section 3 1 3 External GPS Antenna Installation Location for more information on GPS antennae and installation criteria The fi...

Страница 15: ...es The unit should be accessible for maintenance where possible 3 1 2 Criteria for Indoor Locations A minimum of 55 direct Line of Sight LOS exposure of the external GPS antenna to sky The maximum dis...

Страница 16: ...ical damage to the equipment 3 Verify that all of the equipment listed below is included Otherwise contact RuggedCom The base station is shipped with the following equipment The base station unit GPS...

Страница 17: ...tion 4 4 6 Antenna Connections 6 Connect the base station Data Adaptor See Section 4 4 7 Connecting the Base Station Data Adaptor 7 Perform the initial base station setup See Chapter 5 Setup 4 4 1 Cov...

Страница 18: ...r to the following table for the ODU I F connector pinout Pin Number Description Label 1 ETH Data TP0 2 ETH Data TP0 3 ETH Data TP1 4 55V TP2 5 55V TP2 6 ETH Data TP1 7 RTN TP3 8 RTN TP3 Table 4 1 ODU...

Страница 19: ...ousing and align the latch with the latch slot Depress the latch 1 and insert the plug into the plug housing 2 Figure 4 6 Inserting the plug into the plug housing Press the modular plug into the plug...

Страница 20: ...aching the Mounting Bracket Follow these steps to attach the mounting bracket to the base station Figure 4 9 Wall Mounting Bracket Procedure 4 3 Assembling the Base Station and Mounting Bracket 1 Alig...

Страница 21: ...attached to any wall that can support the load of the unit Plan the installation so that the interface connections face down providing more protection against the elements Follow these step to mount...

Страница 22: ...ropriate screws and washers not supplied 4 4 5 Mounting the Base Station Pole Mount The unit can be attached to any pipe or pole with a 1 75 to 10 diameter Plan the installation so that the interface...

Страница 23: ...stallation Procedures RuggedMAX 23 Installation Guide Rev 1 0 Figure 4 12 Base Station and Pole Mounting Bracket 3 Mount the unit on the pole using the metal bands Close the bands tightly around the p...

Страница 24: ...for antenna grounding requirements Connect the antennae to the N Type ANT1 and ANT2 connectors and connect the grounding lug to the common ground 4 4 6 2 Optional External GPS Antenna Connections Remo...

Страница 25: ...uld not exceed 100m The Cat5e Ethernet cable is not included Refer to Appendix C IDU to ODU Cable Specifications for detailed technical specifications 2 Connect the Data Adaptor to a Switch Router by...

Страница 26: ...substitute components Do not disconnect equipment unless power has been switched off or the area is considered to be non hazardous Use only the Lambda DPP50 48 power supply with the equipment RISQUE D...

Страница 27: ...the PoE injector Data Power jack and the pBST 3 Connect a Category 5e cable between the Ethernet switch and the PoE injector Data jack 4 Connect the AC open ended cable to the PSU Figure 4 16 Complet...

Страница 28: ...g system documentation Before beginning ensure that the base station is connected to the Power over Ethernet PoE power adaptor and that power is applied Follow these steps connect a computer to the Wi...

Страница 29: ...og box 7 On the Internet Protocol TCP IP Properties dialog click OK On the Local Area Connection Properties dialog click Close 8 Launch your web browser and type https 192 168 100 100 in the address f...

Страница 30: ...wIPAddr and press Enter The base station s IP address will be displayed 3 Ping the WiN7200 Small Form Factor Base Station unit address 4 If connectivity is still not established contact customer suppo...

Страница 31: ...tute of Electronic and Electrical Engineers IP Internet Protocol LAN Local Area Network LOS Line of Sight NLOS Non Line of Sight NMS Network Management System ODU Outdoor Units QoS Quality of Service...

Страница 32: ...MHz Diversity Support 2x2 STC MIMO SM FEC Convolution Code and Turbo Code Transmit Power Control Output Power average 2 X 27 dBm Modulation 512 1024 FFT points QPSK 16QAM 64QAM Radio Interfaces Number...

Страница 33: ...5 95 non condensing Weather protected Standards Compliance EMC FCC part 15 subpart B class B ETSI EN 301489 1 4 Safety TUV UL 60950 1 IEC 60950 1 Environmental ETS 300 019 Part 2 1 T 1 2 part 2 2 T 2...

Страница 34: ...cal environments The diameter of the inner core complies with RJ45 connecting hardware allowing direct connection to equipment without patch cords Conductor Size 0 52mm Outer Jacket Material UV resist...

Страница 35: ...nominal Max DC Resistance 95 km 20 C Capacitance Unbalance 1 6pF m max Velocity of Propagation 68 nominal Propagation Delay Skew 35 ns 100m max Dielectric Strength 700 V minute Dielectric Strength to...

Страница 36: ...the normal management interfaces cannot be used The console port is based on the RS 232 serial standard and supports a standard terminal connection The Console port enables the technician to configure...

Страница 37: ...tation Base Station Mechanical Drawing RuggedMAX 37 Installation Guide Rev 1 0 Appendix E WiN7200 Small Form Factor Base Station Base Station Mechanical Drawing Figure E 1 WiN7200 Small Form Factor Ba...

Страница 38: ...contains no user serviceable parts Attempted service by unauthorized personnel shall render all warranties null and void For warranty details visit www RuggedCom com or contact your customer service r...

Отзывы: