Description:
Initialize hardware and resources, and get number of
functional borads.
Syntax:
I16 _mnet104_open ()
Argument:
Name
Type
Description
N/C
Return:
Return Value Description
ERR_NoError
The function finished execution successfully.
Other
Please reference to the Appendix error table.
Description:
Get the local DI value.
Syntax:
I16 _mnet104_read_port( U16 Offset, U8 *Val )
Argument:
Name
Type Description
Offset
U16 Pointer the access DI port address
Val [output] U8 * Return the value of local input interface.
Return:
Return Value Description
ERR_NoError
The function finished execution successfully.
Other
Please reference to the Appendix error table.
Description:
Get the local DI value.
Syntax:
I16 _mnet104_write_port( U16 Offset, U8 Val )