2

LRBS-FIX

Before initial usage of the RUD LRBS-

FIX, please read carefully the safety 

instructions. Make sure that you have 

understood all subjected matters. 

  

Non-observance can lead to serious per-

sonal injuries and material damage and 

eliminates warranty. 

1  Safety instructions

ATTENTION 

Wrong positioned or damaged weld-on 

lashing points as well as improper use can 

lead to injuries of persons and damage at 

property, when load falls down. 

Please check all lashing points carefully 

before every usage.

• 

Keep all body parts like fingers, hands, arms, etc. out 

of the hazardous area during the lashing operation.

•  RUD Lashing points LRBS-FIX must only be used 

by instructed and competent persons considering 

DGUV 109-017 (BGR 500), and outside Germany 

noticing the country specific statutory regulations. 

•  Attention: When suspension ring pivots there is a 

risk of pinching.

•  The stated LC (Lashing Capacity) at the LRBS-FIX 

must not be exceeded.

•  Any technical modifications at the LRBS-FIX are 

prohibited.

•  Keep persons out of the hazardous area.
•  Damaged or worn LRBS-FIX must no longer be 

used.

2  Intended use of the LRBS-FIX 

RUD Lashing points LRBS-FIX must only be used to 

attach lashing means. 
The lashing points must not protrude in rest position 

over the loading platform level.

In general, lashing points must not be used for lifting!
RUD Lashing points must only be used in the hereby 

specified case of operation.

3  Assembly- and instruction manual

3.1  General information

•  Capability of temperature usage:

As of 07/2019: RUD Lashing points LRBS-FIX are 

suitable for the temperature range from -40°C up 

to 400°C.
Up to 07/2019: RUD Lashing points LRBS-FIX are 

suitable for the temperature range from -20°C up 

to 400°C.
For the use within the following temperature range, 

the WLL must be reduced by the following factors:
-40°C / -20°C up to 200°C  no reduction 

 

200°C up to 300°C:  

by -10 % and

300°C up to 400°C:  

by -25 %

Temperatures exceeding 400°C are prohibited

  In the unloaded state, LRBS-FIX Lashing points 

together with the load can be stress relieved by 

heat treating (e.g. welded construction) once. 

Temperature: < 600°C (one hour maximum). 

After stress-relieving heat treatment (< 600°C), 

however,the spring force is no longer usable.

•  RUD Lashing points LRBS-FIX must not be used 

with aggressive chemicals such as acids, alkaline 

solutions and their vapours.

•  Please mark mounting position of Lashing point 

with a coloured contrast paint for better visibility.

•  LRBS-FIX includes a protected positioned clam-

ping spring, inside the weld-on block. The spring 

holds the weld-on blocks together with the ring 

and creates at the same time a radial clamping 

function.

•  RUD Lashing points LRBS-FIX are clearly mar-

ked at the suspension ring with the permissible 

Lashing capacity „LC“ in daN.

•  LRBS-FIX will be delivered as a complete assem-

bled unit.

3.2  Hints for the assembly

Basically essential:
•  The material construction to which the lashing point 

will be attached should be of adequate strength to 

withstand forces during lashing without deformation. 

The weld-on material must be suitable for welding 

and the contact areas must be free from dirt, oil, 

colour, ect.

  The material of the forged welding block is: 

N (1.0577+N (St52-3))

•  The position of the lashing points must be carried 

out in regard to the lashing means in such a way 

that unintended movement like turning or flipping 

of the load will be avoided.

INHALT
1  Safety instructions 

2

2  Intended use of the LRBS-FIX  

2

3  Assembly- and instruction manual 

2

3.1  General information ..................................................2

3.2  Hints for the assembly ..............................................2

3.3  Hints for the welding .................................................3

3.4  User instructions .......................................................3

4  Inspection / Repair / Disposal 

4

4.1  Hints for the regularly inspection ..............................4

4.2  Inspection criteria for the regularly 

examination carried out by the operator ...................4

4.3  Additional inspection criteria for the  

competent person resp. auditor ................................4

4.4 Disposal ....................................................................4

5 Tables/Overview 

4

Содержание LRBS-FIX

Страница 1: ...Gültigkeit Weiterhin verliert diese Erklärung ihre Gültigkeit wenn die Ausrüstung nicht entsprechend den in der Betriebsanleitung aufge zeigten bestimmungsmäßigen Fällen eingesetzt wird Hinweis Beim Zurrpunkt angewendete harmonisierte Normen DIN EN ISO 12100 T1 und T2 sowie in An lehnung an EN 1677 Bezeichnung der Ausrüstung Zurrpunkt Type Ringbock schweißbar Herstellerzeichen Declaration of the m...

Страница 2: ...200 C no reduction 200 C up to 300 C by 10 and 300 C up to 400 C by 25 Temperatures exceeding 400 C are prohibited In the unloaded state LRBS FIX Lashing points together with the load can be stress relieved by heat treating e g welded construction once Temperature 600 C one hour maximum After stress relieving heat treatment 600 C however the spring force is no longer usable RUD Lashing points LRBS...

Страница 3: ...ng point see chapter 4 Inspection Repair Disposal HINT By the position of the weld seam HY weld circumferential the following requirements will be observed DIN 18800 steel con structions requires at outdoor buildings or when strong corrosion must be expected weld seams must be carried out as conti nuous fillet weld seams 3 4 User instructions Check frequently and before each initial operation the ...

Страница 4: ...d readable marking of Lashing Capa city as well as manufacturer sign Deformation at load bearing components like base body and Ring Mechanical damage like strong notches especial ly in areas where tensile stress occurs 4 3 Additional inspection criteria for the competent person resp auditor Reduction of cross section due to wear 10 Evidence of corrosion pitting Additional inspections may be necess...

Страница 5: ...IX kompl LC daN A mm B mm C mm D mm E mm F mm T mm weight kg pc Ref no LRBS FIX 8 000 8 000 60 14 39 48 132 69 74 0 93 7999303 LRBS FIX 13 400 13 400 88 20 50 60 167 91 97 2 2 7999304 LRBS FIX 20 000 20 000 100 22 60 65 191 100 108 3 7 7999305 LRBS FIX 32 000 32 000 130 30 72 90 267 134 140 8 0 7999306 Table 3 Dimensioning LRBS FIX complete Subject to technical alterations Type Lashing Ring LC daN...

Отзывы: