Figure 10. Attaching the T-bar bracket to the T-bar

E

(Optional) Attach a customer-supplied padlock through the bracket AP retainer tab (B 
in 

Figure 9

) to lock the AP to the T-bar bracket studs.

When you are done, the AP is mounted.

Removing the AP from the T-bar:

 

A

Move the ceiling tiles out of the way, if present.

B

Gently lift up the locking tab (A in 

Figure 11

) by sliding your finger under the tab. 

C

Rotate the AP- and-T-bar bracket assembly (B in 

Figure 11

). The AP- and-T-bar 

bracket assembly comes away from the T-bar.

Figure 11. Removing the AP and T-bar bracket from the T-bar

Removing the T-bar bracket from the AP:

 

A

If the AP is locked to the T-bar bracket, then remove the lock.

B

Gently lift up the T-bar bracket locking tab (A in 

Figure 12

) and push the AP retainer 

tab (B in 

Figure 12

) to the side at the same time. 

C

While lifting up the T-bar bracket locking tab and pushing the AP retainer tab to the 
side, gently push the T-bar bracket (C in 

Figure 12

) toward the Ethernet ports on the 

bottom of the AP until the bracket detaches from the AP.

Figure 12. Removing the T-bar bracket from the AP

Mounting on a Flat Surface

The factory-supplied mounting screws and plastic wall anchors allow you to attach the AP 
to a wall or ceiling.

A

Use the Mounting Template on the last page of this 

Quick Setup Guide 

to mark the 

locations for two drill holes on the mounting surface. 

Note:

 There is a second set of 

keyholes that are for optional sideways mounting on a flat surface. Physical security 
is not supported when mounting the AP with this set of keyholes. 

B

Use a 4.75mm (3/16”) drill bit to drill holes approximately 25mm (1”) deep into the 
mounting surface.

C

Insert the factory-supplied anchors (A in 

Figure 13

) and mounting screws (B in 

Figure 13

) into the mounting surface, leaving approximately 6 mm (1/4”) of the 

screw heads protruding for the AP enclosure. 

Figure 13. Flat surface mounting

A

Place the AP onto the mounting screws so the screw heads enter the keyholes on 
the AP enclosure, and push the AP down until the AP retainer tab (B in 

Figure 12

snaps into place.

B

(Optional) Attach a customer-supplied padlock through the integral AP retainer tab (B 
in 

Figure 12

) to lock the AP to the mounting screw heads.

C

To remove the AP from the factory-supplied mounting screws, push sideways on the 
AP retainer tab (B in 

Figure 12

), to unlock, then push the AP up to release the AP 

enclosure from the mounting screws.

Mounting on a Flat Surface or Pole Using the 
Optional Secure Mounting Bracket

The customer-ordered Ruckus Wireless secure mounting bracket kit (ordering part 
number 902-0120-0000) includes a metal mounting bracket and provides greater 
security when attaching the AP to flat surfaces (walls and ceilings) and to poles. 

If you are mounting the AP on a flat surface, then you will also need an electric drill 
with a 4.75mm (3/16”) drill bit, and the four No. 6 zinc plated screws and plastic wall 
anchors included with the kit. 

If you are mounting the AP on a truss or pole, then you will also need the two pipe 
clamps included with the kit.

Continue with the following:

A

If you are mounting the AP on a flat surface, then use the secure mounting bracket 
as a template to mark the locations for four drill holes on the mounting surface. 
There are four screw holes available on the secure mounting bracket. 

Fasten the bracket to the flat surface using four mounting screws and plastic wall 
anchors and continue with 

Step D

.

B

If you are mounting the AP on a pipe or pole, then feed the two stainless steel 
clamps included with the kit through the slots on the secure mounting bracket. Use 
common hand tools to tighten the clamps around the pipe or pole.

C

After the bracket is attached, continue with 

Step D

.

D

Insert the two studs on the secure mounting bracket into the keyholes on the bottom 
of the AP, as shown in 

Figure 9

Note:

 

There is a second set of keyholes that are 

for optional sideways mounting on a flat surface. Physical security is not supported 
when mounting the AP with this set of keyholes. 

E

Slide the AP toward the Ethernet ports on the AP. The AP has a built-in lock for the 
secure mounting bracket studs, and snaps into the locked position when the studs 
are fully in the keyholes.

F

(Optional) Attach a customer-supplied padlock through the integral AP retainer tab (B 
in 

Figure 12

) to fasten the AP to the secure mounting bracket studs.

Removing the AP from the secure mounting bracket:

 

A

If the AP is locked to the secure mounting bracket, then remove the lock.

B

Gently push and hold the AP retainer tab (B in 

Figure 12

) to the side to release the 

secure mounting bracket.

C

While holding the AP retainer tab to the side, slide the AP away from the Ethernet 
ports on the bottom of the AP.

F

OR

 M

ORE

 I

NFORMATION

For information on how to configure and manage your Unleashed network, refer to the 

Ruckus Wireless Unleashed Access Point Online Help

, available by clicking the “Help” 

button from within the user interface, or from 

https://docs.ruckuswireless.com

.

A

B

A

B

C

B

A

A

B

Note: 

For more complete instructions, refer to the Mounting Guide that comes with 

the secure mounting bracket.