This 

Mounting Guide

 provides step-by-step instructions on how 

to field-install the Ruckus Wireless ZoneFlex 7782 Omni (9x1-
7782-xx01), 7782-N 30-Degree Narrow Sector (9x1-7782-xx61), 
and 7782-S 120-Degree Sector (9x1-7782-xx51) access point 
(AP). Unless specifically indicated, the rest of this document refers 
to the 7782, 7782-N and 7782-S access points as APs.

For detailed information on planning the installation, pointing the 
internal GPS antenna, performing a site survey, preparing the AP 
at the depot and shipping to the field, refer to the 

ZoneFlex 7782 

Dual Band 802.11n Outdoor Access Point Installation Guide

. For 

information on operating the AP, refer to the 

ZoneFlex Outdoor 

Access Point User Guide

. Both documents are available at 

https://support.ruckuswireless.com

.

WARNING:

 

Only trained and qualified personnel should be 

allowed to install, replace, or service this equipment.

 

WARNING: 

Installation of this equipment must comply with local 

and national electrical codes.

 

CAUTION:

 

Make sure that you form a 80mm - 130mm (3”-5”) 

drip loop in any cable that is attached to the AP or the building. 
This will prevent water from running along the cable and entering 
the AP or the building where the cable terminates. 

CAUTION:

 

Be sure that grounding is available and that it meets 

local and national electrical codes. For additional lightning 
protection, use lightning rods and lightning arrestors.

 

CAUTION:

 

Make sure that proper lightning surge protection 

precautions are taken according to local electrical code.

 

WARNING:

 

Ruckus Wireless strongly recommends that you wear 

eye protection before mounting the AP.

B

EFORE

 Y

OU

 B

EGIN

Before deploying Ruckus Wireless products, please check for the 
latest software and the release documentation.

User Guides and Release Notes are available at

http://support.ruckuswireless.com/documents

Software Upgrades are available at

http://support.ruckuswireless.com/software

Open Source information is available at

http://opensource.ruckuswireless.com

Software License and Limited Warranty available at

http://support.ruckuswireless.com/warranty

T

HIS

 G

UIDE

 

IN

 O

THER

 L

ANGUAGES

请从以下网站获得该指南的简体中文版

 

https://support.ruckuswireless.com

.

Vous trouverez la version française de ce guide à l'adresse 
suivante 

https://support.ruckuswireless.com

.

こ の ガ イ ド の日本語版は 

https://support.ruckuswireless.com

 

で ご覧 く だ さ い。

 

가이드의

 

한국어

 

버전은

 

 

사이트

(

https://support.ruckuswireless.com

)

에서

 

확인하시기

 

바랍니

.

Veja a versão em português (Brasil) deste guia em 

https://support.ruckuswireless.com.

Puede ver la versión en español (América Latina) de esta guía 
en 

https://support.ruckuswireless.com.

P

ACKAGE

 C

ONTENTS

Before deploying your AP in the field, verify that all items listed 
below are included in the package. If any item is damaged or 
missing, notify your authorized Ruckus Wireless sales 
representative. Also, make sure that you have the required 
hardware and tools. 

One 7782, 7782-N or 7782-S AP (A in Figure 1); includes one 
12mm stainless steel M6x1 earth ground screw with split lock 
and flat washers

One AC power cable input end connector (B in Figure 1)

Two M25 data cable glands (C in Figure 1)

One green/yellow earth ground wire with ring terminal (D in 
Figure 1)

One loop-and-eye safety cable (E in Figure 1)

One wall- or pole-mount hanger mount (F in Figure 1)

One extension bracket (G in Figure 1)

One AP mounting bracket (H in Figure 1)

Two sets 40mm stainless steel M8x1.25 hex bolt with split 
lock and flat washers (I in Figure 1)

Four SAE32-sized stainless steel clamps, 1.5- to 2.5-inch 
diameter (J in Figure 1)

Four sets 0.625-inch stainless steel 0.250-28 hex bolt with 
split lock and flat washers (K in Figure 1)

Four sets 12mm stainless steel M4x0.7 Phillips pan-head 
screws with split lock and flat washers L in Figure 1)

NOTE: 

This kit may include extra screws, nuts and washers. You 

may use the extras wherever required.

Figure 1:

AP field-installation package contents

The field installation package can also include: 

Service Level Agreement/Limited Warranty Statement

Regulatory Statement

Registration card

Declaration of Conformity, if required

This 

Mounting Guide

 

R

EQUIRED

 H

ARDWARE

 

AND

 T

OOLS

Torque wrench or torque screwdriver with sockets and bits

Long-nose pliers

Small and wide flat-blade screwdrivers

Electrical wire stripping and terminal crimping pliers

Customer-supplied outdoor-rated Cat5e UTP RJ-45 Ethernet 
cable with 4.0mm to 6.5mm (0.17" to 0.26") round cable 
sheath

If you are mounting the AP on a flat surface, then you will also 
need:

Customer-supplied wall anchors with up to M6 or 0.25” 
stainless steel screws rated to withstand 128 N or 28.8 lbf 
(required to withstand wind loads of 266km/h or 165mph)

Electric drill with drill bits and customer-supplied wall anchors, 
flat washers, and hex nuts for flat-surface mount

If you are mounting the AP on a pipe or pole, then you will also 
need:

A 38mm to 63mm (1.5" to 2.5") pipe or pole

Four factory- or customer-supplied stainless steel clamps

CAUTION!

The minimum software revision for all 7782 APs is 

ZoneFlex (ZF) 9.5.1 or SmartCell Gateway (SCG) 1.1.1 or later. 

DO NOT CONNECT ANY 7782 AP TO A RUCKUS WIRELESS 
CONTROLLER WITH ZF 9.5.0 OR SCG 1.1.0 OR EARLIER.

 

F

G

H

E

A

C

B

D

I

J

K

A

B

L

Содержание ZoneFlex 7782

Страница 1: ... 다 Veja a versão em português Brasil deste guia em https support ruckuswireless com Puede ver la versión en español América Latina de esta guía en https support ruckuswireless com PACKAGE CONTENTS Before deploying your AP in the field verify that all items listed below are included in the package If any item is damaged or missing notify your authorized Ruckus Wireless sales representative Also mak...

Страница 2: ...r mount A in Figure 3 and thread the eye end through the loop end B in Figure 3 Figure 3 Hanger mount on a flat surface NOTE Hanger mount shown attached horizontally to allow AP azimuth adjustments Attach the hanger mount vertically to allow AP elevation adjustments 7 Continue with Step 3 Assembling the AP Mounting Bracket and the AP STEP 2B ATTACHING THE HANGER MOUNT TO A METAL POLE 1 Insert the ...

Страница 3: ...and finger tighten until the bolt passes through the screw hole on the hanger mount Figure 10 Finger tightened hex bolt 3 Align the hole on the mounting bracket with the remaining hole on the extension bracket 4 Insert an M8 hex bolt into the hole and finger tighten until the bolt passes through the extension bracket Figure 11 Dome down mounting 5 Adjust the azimuth and elevation of the AP as requ...

Страница 4: ...7 Mate the boot with the cable gland and then hand tighten to seal 8 Connect the AC cord connector that you have assembled to the AC power socket on the AP 9 Connect the AC cord to an AC power source TROUBLESHOOTING CAUTION If required you can reset the AP to its factory default settings by pressing the reset button located inside the PoE OUT RESET port DO NOT DO THIS UNLESS SO INSTRUCTED Doing th...

Отзывы: