Installation, operating and maintenance instructions

DVN...D.F4

2.  IMPORTANT INFORMATION

1. FOREWORD

Dear customers,
Thank you very much for choosing ruck Ventilatoren GmbH.
Before operating the unit, please read carefully these installation, operating and maintenance instructions. If you have 
any questions, please contact:

The data provided in these installation, operating and maintenance instructions are for the product description only. A 
statement about a certain condition or a suitability for a certain application cannot be derived from our information. 
The information does not release the user from his own assessments and examinations.

All rights belong to ruck Ventilatoren GmbH, also in the case of industrial property rights applications.
Any disposal such as copying and distribution rights lies with us.

The title page shows an example configuration. The delivered product may therefore differ from the illustration.

The original instructions were created in the German language.

Information updated print 28.08.2018

Subject to change

This manual contains important information on the safe and appropriate assembly, transport, commissioning, operation, 
maintenance, disassembly and simple troubleshooting of the product.
The product has been manufactured according to the accepted rules of current technology. 
There is, however, still a danger of personal injury or damage to equipment if the following general safety instructions and 
the warnings before the steps contained in these instructions are not complied with.

 

Read these instructions completely and thoroughly before working with the product.

 

Keep these instructions in a location where they are accessible to all users at all times.

 

Always include the operating instructions when you pass the product on to third parties.

2.1.  Applicable Documents

The following documents and information on the exhaust fan must be observed in addition to the installation, ope-
rating and maintenance instructions:

 

DIN VDE 0100-100

 

DIN EN 60204-1

 

DIN EN ISO 13857

 

DIN EN ISO 12100

 

DIN EN 12101-3

 

VDMA 24186-1

 

Nameplate

ruck Ventilatoren GmbH
Max-Planck-Str. 5
D-97944 Boxberg-Windischbuch
Tel. 

+49 (0)7930 9211-300

Fax 

+49 (0)7930 9211-166

[email protected]     
www.ruck.eu

 

    certified 

ISO 

9001:2015 

(51017552)

Содержание DVN 225 D2 F4 30

Страница 1: ...THE FOLLOWING INSTRUCTIONS 5 5 PRODUCT INFORMATION 6 6 NAMEPLATE 7 7 TECHNICAL DATA 8 8 DIMENSIONS 8 9 DATA IN ACCORDANCE WITH ERP DIRECTIVE 327 2011 OF THE EUROPE AN PARLIAMENT 9 10 TRANSPORT AND ST...

Страница 2: ...8 2018 Subject to change This manual contains important information on the safe and appropriate assembly transport commissioning operation maintenance disassembly and simple troubleshooting of the pro...

Страница 3: ...ure 3 GENERAL SAFETY INSTRUCTIONS Planners plant engineers and operators are responsible for ensuring that the product is installed and operated correc tly Use our devices only in perfect technical co...

Страница 4: ...uctions before the steps whenever there is a danger of personal injury or damage to the equipment The measures described to avoid these hazards must be observed Safety instructions are set out as foll...

Страница 5: ...r the influence of alcohol drugs or pharmaceuticals that may affect perception and responsiveness Responsibilities for the operation maintenance and regulation of the product should be clearly determi...

Страница 6: ...d may result in death injury or damage to property Before performing any work on conductive parts al ways disconnect the unit completely from the electri city supply and make sure that it cannot be sw...

Страница 7: ...D Item number SN Serial number Air direction arrow ErP 2015 Catalog item number Test date CE mark Grounding Series perm temperature time in smoke extraction perm temperature in continuous operation DV...

Страница 8: ...173 452 467 363 341 484 517 245 4x 9 213 6x M6x15 142175 452 467 363 341 484 517 245 4x 9 213 6x M6x15 142177 569 512 464 441 531 617 330 4x 11 286 6x M6x15 142179 569 512 464 441 529 617 330 4x 11 28...

Страница 9: ...such as ducts that are not described in the measure ment category and not supplied with the fan Units Model ID number see nameplate ruck Ventilatoren GmbH Local District Court Mannheim HRB 560367 Germ...

Страница 10: ...n If moisture has penetrated into the original packaging remove it immediately Storage temperature between 5 C and 40 C Avoid severe temperature fluctuations If the product has been in storage for mor...

Страница 11: ...he nozzle plate 4 with hexagonal screws and sealing washers 5 6 on roof socket DSS DSF If required it is possible to install further accessories at this point see 11 3 Installation examples with acces...

Страница 12: ...126383 EN Installation operating and maintenance instructions DVN D F4 11 3 Installation examples DSF DAP DVK DAS DAF Tube Roof fan DSF DAP DVK DAF Tube Roof fan DSF DAS DAF Tube Roof fan DSF Tube DS...

Страница 13: ...oosely lubricate the threaded pins 3 and screw in do not tighten yet 4 Push the impeller onto the shaft with the clamping sleeve align it in the axial position and tighten the threaded pins evenly on...

Страница 14: ...er one s own personal responsibility The electrical connections must be made as shown in the corresponding wiring diagrams and terminal diagrams The type of cable size of cable and method of laying sh...

Страница 15: ...as accessories These are pre programmed and delivered exactly matched to the respective engine power and speed 12 1 Unit supply cable 12 2 Frequency converter If third party products are used the fol...

Страница 16: ...e terminals U2 V2 and W2 are connected through the shorting blades see Img Never connect both jumpers at the same time The star circuit must be used if the motor is to be ope rated directly on the 3 p...

Страница 17: ...bearing for noise yearly Check terminals for tight fit yearly Measure the voltage yearly 13 COMMISSIONING Electricity warning hazardous voltage Failure to observe the hazard may result in death injur...

Страница 18: ...SAL 15 2 Decommissioning and disposal When disassembling parts under voltage are exposed which can lead to electric shock when touched Before dismantling disconnect the fan from all poles of the mains...

Страница 19: ...impeller Contact the supplier Connection with intake or exhaust pipe causes vibrations and oscillations Install fan with vibration dampers Fixing screws released Tighten screws Fault of the ball beari...

Страница 20: ...8 mdnuf_pb_01_en We reserve the right to make changes Language English ruck Ventilatoren GmbH Max Planck Str 5 D 97944 Boxberg Windischbuch Tel 49 0 7930 9211 300 Fax 49 0 7930 9211 166 info ruck eu w...

Отзывы: