background image

 

 
 

Содержание RC-1001

Страница 1: ......

Страница 2: ...Publication date March 2011 Revision A2 i User s Manual Web Smart 10 100Base TX to 100Base FX Media Converter Release 1 04...

Страница 3: ...ration 12 3 3 4 Port Configuration 14 3 3 5 MIB Counter 16 3 3 6 VLAN 17 3 3 6 1 VLAN Group 17 3 3 6 2 VLAN Per Port Setting 19 3 3 7 Q in Q 21 3 4 REMOTE SETTING 23 3 4 1 TS 1000 Functions 23 3 4 1 1...

Страница 4: ...Publication date March 2011 Revision A2 iii Revision History Release Date Revision 0 96 12 04 2009 A1 1 01 10 7 2010 A1 1 02 10 29 2010 A1 1 04 03 03 2011 A2...

Страница 5: ...onic Emission Notices Federal Communications Commission FCC Statement This equipment has been tested and found to comply with the FCC Part 15 Subpart B Class A CISPR 22 A1 2000 A2 2002 ICES 003 2004 C...

Страница 6: ...ONVERTER through the built in web by Ethernet ports step by step Many explanations in detail of hardware and software functions are shown as well as the examples of the operation for web based interfa...

Страница 7: ...Management Supports Web UI for management Supports OAM for remote management via TS 1000 Supports OAM for remote management via IEEE802 3ah Supports Ingress Egress Rate Limitation Supports Link Loss...

Страница 8: ...ins the following Web Smart Media Converter AC DC Power adapter This User s Manual CD Please notify your sales representative immediately if any of the aforementioned items is missing or damaged Model...

Страница 9: ...n POWER Green Lit when 5V power is coming up FX LINK ACT Green Lit when fiber connection is good Blinks when any traffic is present TP LINK ACT Green Lit when TP connection is good Blinks when any tra...

Страница 10: ...le Cable pin outs for RJ 45 jack 1 2 3 6 to 1 2 3 6 to cascade or up link the converter to an upper layer L2 L3 switch or server host workstation TP Cable Limitations Cat 5 and up to 100m Fiber Cable...

Страница 11: ...nction by Ethernet Port Browser to manage and monitor the port activity For instance http 192 168 1 1 then enter password and click Login button The default values of Web Smart Media Converter are as...

Страница 12: ...introduced in the following sections On the front panel the LEDs will display the status color which is the same as physical hardware The fiber and TP plug will display the status color as well Green...

Страница 13: ...e management agent in this device Software Version It s a firmware version of this device IP address Gateway Subnet Mask It s an IP address of the device Default Setting IP Address 192 168 1 1 Default...

Страница 14: ...ement For offering you a clear guide to use this Web Smart Media Converter the following is the whole function tree of Web Smart Media Converter in web management User can refer to the following secti...

Страница 15: ...to view the device WEB SMART MEDIA CONVERTER supports both manual IP address setting and automatic IP address setting via DHCP server When IP address is changed you must reboot the converter to have t...

Страница 16: ...isable Then click Apply button to update it Default 192 168 1 1 Subnet mask Set the subnet mask value which is the same as that of network it attaches For more information please also see the section...

Страница 17: ...ied or deleted and is the only one user account The password must be a z A Z 0 9 and _ The max length is 16 characters After input the data as Fig 3 6 click Apply button The default setting of user ac...

Страница 18: ...iption Jumbo Frame 9K If enable this function the media converter could pass the max 9KB packets Link Transparent Only if link transparent is enabled the Remote Fault Detect and Link Loss Carry Forwar...

Страница 19: ...f it is a dump MC And the configuration of remote side is the same as local side Forward CRC Error Frame If enable this function the CRC error packet will be pass otherwise the CRC error packets will...

Страница 20: ...port current link status 100F Speed 100M Full Duplex Mode 100H Speed 100M Half Duplex Mode 10F Speed 10M Full Duplex Mode 10H Speed 10M Half Duplex Mode Down Link Down Mode The Auto Speed algorithm t...

Страница 21: ...itting device s while the receiving port is too busy to handle When it is set Disable flow control will not exist in the port It drops the packet if too much to handle Default Enable Ingress Rate Limi...

Страница 22: ...If click the clear button all MIB counters will be clear to zero Click the refresh button show the current MIB counters again Parameter description TP To display the converter UTP port counter inform...

Страница 23: ...g it you can gain not only improving security and increasing performance but greatly reducing VLAN management 3 3 6 1 VLAN Group Function name 802 1Q VLAN Group Function description If enable VLAN fun...

Страница 24: ...tag based VLAN group has a unique VID It appears only in tag based and Double tag mode TP To evoke the TP The converter s UTP port to become a VLAN group member FX To evoke the FX The converter s Fib...

Страница 25: ...d an insertion for untagged packets Remove Tag The switch will remove VLAN tags from packets if they are tagged when these packets are output The switch will not modify packets received without tags A...

Страница 26: ...Publication date March 2011 Revision A2 20 Enable or Disable VLAN ingress filter...

Страница 27: ...Publication date March 2011 Revision A2 21 3 3 7 Q in Q Function name Q in Q Function description This page could configure Q in Q function Fig 3 12 Fig 3 13...

Страница 28: ...N VID User defined Q in Q out layer VLAN tag VID VLAN Tag Priority Decision Decide out layer VLAN Tag s priority use internal VLAN tag priority or use IP remarking priority Q in Q direction Select Q i...

Страница 29: ...Remote Port Setting five functions 3 4 1 1 TS 1000 Setting Function name TS 1000 Setting Function description This page could enable disable TS1000 function and set TS 1000 mode as terminal or center...

Страница 30: ...Publication date March 2011 Revision A2 24 Fig 3 15...

Страница 31: ...n description This page could start TS1000 loopback function User could set TS1000 loopback packet number Fig 3 16 Parameter description Send packet number After input the number between 1 and 255 cli...

Страница 32: ...Function description We could reset remote device through this function Before that TS1000 ability should be enabled local device should be set in center mode and remote device should be set in termin...

Страница 33: ...escription This page shows remote device port information Fig 3 18 3 4 1 5 Remote Port Setting Function name Remote Port Setting Function description In this page user could enable disable remote devi...

Страница 34: ...figuration Function description This page could set IEEE802 3ah OAM function User could enable disable 802 3ah function and set its mode as passive or active mode Fig 3 20 Parameter description 802 3a...

Страница 35: ...age could start 802 3ah loopback test User could configure packet length and packet number Fig 3 21 Parameter description Send Packet Number Available value 1 255 Packet Length Not include CRC Availab...

Страница 36: ...Publication date March 2011 Revision A2 30 3 4 2 3 802 3ah Status Function name 802 3ah Status Function description This page shows 802 3ah status information Fig 3 24...

Страница 37: ...stem Reboot Save and Restore Firmware Upgrade and Logout four functions Fig 3 25 3 5 1 System Reboot Function name System Reboot Function description Click this function to reboot the device Fig 3 26...

Страница 38: ...evision A2 32 3 5 2 Save and Restore Function name Save and Restore Function description SaveToFlash Save local configuration to flash LoadFromFlash Restore last saved configuration ResetToFactory Fac...

Страница 39: ...e new firmware image file and then the new code image will be burned into the flash and reset the device to use the new firmware Fig 3 28 Parameter description Browse To select the location of the fir...

Страница 40: ...ugh the WEB SMART MEDIA CONVERTER Converter The network device of Computer C may fail to work Please check the link act status of Computer C on the LED indicator Try another network device on this con...

Страница 41: ...VDC Power consumption 1 5 W Fiber Connector RC 1001 SC LC RC 1001A SFP Ambient Temperature 0 to 50 C Humidity 5 to 90 Dimensions 70 3 W x 26 2 H x 94 D mm Weight 0 44kg Safety Comply with FCC Part 15...