background image

TROUBLESHOOTING

Is the adjustable temp.control turn to maximum.
Is the mixer tap adjusted correctly.
Is the water heater given enough time to heat up.(if the 
temp.reaches the preset temp.,the red heater lamp will 
go OFF automatically).
Is the water heater capacity enough for the purpose.

Symptoms 

Solutions

A. No water coming out of 
     the heater 

Check whether all stop valves are opened.
Check whether the water supply is there.
Check whether the pressure relief valve over tighten.
Check whether inlet water supply connected to 
Pressure relief valve

B. Water heater is not working 

Check whether power supply is ON.
Is the main lamp ON.
Is the heater lamp ON.
Is the adjustable temp.control ON.
Is the mixer tap connected correctly.

C.Water not hot enough 

If any of the following abnormalities are present during usage, contact our service 
centres nearest to you or your sales agent immediately:
A. Water leakage.
B. Water temperature cannot be controlled.
C. Power and heating light does not light up.

Noted: The specifications of product is subjected to change& improvement without prior notice.

10

3. Suggest to examine the aluminum anode yearly or replace it every two years. To 

    do so, dismantle the heating element from the heater and unscrew the anode from 

    the supporting bracket.

2. To ensure the heater operates efficently, it is recommended to clean the inner 

    container and the deposits on the heating element once every two years.

4. In order to drain water out, it is important to check that the water heater has been 

    switched off long enough for the water inside to cool down before removing the 

    pressure relief valve. Flush the valve with water to remove any deposit of salts. 

    The valve can be removed and reattached by use of a wrench.

5. Disconnection of the water heater must be incoporated in the fixed wiring in 

    accordance with the wiring rules.

6. Check on a regular basis that pressure relief valve is operating correctly.

Содержание RSH-M100L

Страница 1: ...RSH M30L RSH M50L RSH M80L RSH M100L Electric Storage Water Heater User Manual...

Страница 2: ......

Страница 3: ...through a double pole linked switch having a contact separation of at least 3mm in all poles incorporated in the circuit 8 It is recommented to install an approved residual current device RCD of 10mA...

Страница 4: ...55 440 785 440 935 Outlet Tube Isolation Barrier Pressure Relief Valve Cold Water Inlet Thermostat Aluminum Anode Temperature Control Knob 2 Remark 1 Liter of water 1 kg a Thermal cut out will break t...

Страница 5: ...NTING POSITION DIAGRAM 1 Left Wall Mounting 2 Right Wall Mounting 4 Floor Mounting 3 Ceiling Mounting Dimensions Ensure that the heater Hot outlet is always parallel above the Cold inlet after each in...

Страница 6: ...er to g 1 2 According to site requirements you may regulate the position of the exible mounting bracket to oor ceiling or wall mounting con guration Once the position is con rmed please ensure to secu...

Страница 7: ...unting Left or Right For mounting of heater on wall drill two holes of distance L on the wall depending on models and tighten the explosive bolts till 7 10mm from wall Slowly lay the heater onto the e...

Страница 8: ...w Tube to Drain or Floor Trap D Hot Water Outlet E Isolation Barrier A D E B C 6 CONNECTION OF OVERFLOW TUBE Connect Over ow tube leading downward to drain or oor trap DO NOT connect over ow tube lead...

Страница 9: ...electric shocks 3 Pressure Relief Valve The pressure relief valve prevents excessive pressure built up in the heater tank and must not be removed or replaced In the event the pressure in the tank exce...

Страница 10: ...low E Incoming Wires Brown L Blue N 8 ELECTRICAL CONNECTION This electric storage water heater is completely factory wired to 3 way connector with L LIVE N NEUTRAL and E EARTH marking 1 Switch off the...

Страница 11: ...B RCCB METHODS OF USE 2 Check for any water leaks on all the pipe ttings and the heater body 3 Turn on the power supply to the heater the HEATING indicator at the heater front panel will light up and...

Страница 12: ...your sales agent immediately A Water leakage B Water temperature cannot be controlled C Power and heating light does not light up Noted The speci cations of product is subjected to change improvement...

Страница 13: ...RSH M30L RSH M50L RSH M80L RSH M100L Simpanan Air Pemanas Elektrik Manual Pengguna...

Страница 14: ...at pemanas ini mesti disambungkan tetap pada bekalan elektrik menggunakan suis dua kutub yang mempunyai pemisahan sentuhan sekurang kurangnya 3mm pada semua kutub yang dirangkumkan dalam pendawaian te...

Страница 15: ...5 IPX4 IPX4 IPX4 IPX4 355 520 355 755 440 785 440 935 Pelindung Penebat Injap Pelepas Tekanan Saluran Masuk Air Sejuk Anod Aluminium Nota 1 liter air 1 kg a Pemutus termal akan memutuskan arus ke ele...

Страница 16: ...DUKAN PELEKAP 1 Pelekap Dinding Kiri 2 Pelekap Dinding Kanan 4 Pelekap Lantai 3 Pelekap Siling Dimensi Pastikan saluran keluar air Panas berada di atas dan selari dengan saluran masuk air Sejuk selepa...

Страница 17: ...lat pemanas ini sila rujuk rajah 1 2 Dengan berdasarkan keperluan tapak pemasangan anda boleh menyesuaikan kedudukan pendakap pelekap eksibel dengan kon gurasi pelekap lantai siling atau dinding Setel...

Страница 18: ...b Pelekap Dinding Kiri atau Kanan Untuk memasang alat pemanas pada dinding gerudi dua lubang pada dinding dengan jarak L seperti dinyatakan dalam jadual di bawah bergantung kepada modelnya dan ketatka...

Страница 19: ...iran Lantai D Saluran Keluar Air Panas E Halangan Pengasingan A D E B C 6 PENYAMBUNGAN TIUB LIMPAHAN 1 2 3 4 Sila pasang alat pemanas mengikut arah anak panah Dinding Dinding Masuk Masuk Masuk Masuk D...

Страница 20: ...n berfungsi untuk menghalang tekanan berlebihan yang terbentuk di dalam tangki alat pemanas dan tidak boleh ditanggalkan atau diganti sama sekali Sekiranya tekanan di dalam tangki melebihi 0 8MPa inja...

Страница 21: ...HIDUP N NEUTRAL dan E BUMI 1 Matikan kuasa elektrik 2 Tanggalkan keempat empat skru A B C D penutup hadapan alat pemanas sila rujuk Rajah 6 3 Sambungkan wayar elektrik seperti berikut dengan merujuk k...

Страница 22: ...dian buka saluran masuk air utama di rumah anda Apabila air yang mengalir keluar dari tap air panas menjadi normal tanpa bunyi berdengung ini bermakna tangki telah diisi penuh dengan air dan udara di...

Страница 23: ...enyala Adakah lampu alat pemanas menyala Adakah kawalan suhu boleh laras menyala Adakah tap campuran disambungkan dengan betul C Air tidak cukup panas 2 Untuk memastikan alat pemanas berfungsi dengan...

Страница 24: ...nyelenggaraan kami yang terdekat dengan anda atau ejen jualan anda dengan segera A Kebocoran air B Suhu air tidak dapat dikawal C Lampu penunjuk untuk kuasa dan pemanasan tidak menyala Nota Spesi kasi...

Отзывы: