3
In
teg
ra
tio
n
Gu
id
e
Installation Orientation
There are two threaded mounting holes in the bottom of the RT211 for fastening the engine to a mounting
surface with machine screws. The following figure illustrates a front view of the RT211 after correct
installation.
Optics
Window Placement
The window should be positioned properly to let the illumination and aiming beams pass through asmuch as
possible and no reflections back into the engine (reflections can degrade the reading performance).
The window should be mounted close to the front of the engine (parallel). The maximum distance is
measured from the front of the engine housing to the farthest surface of the window. In order to reach better
reading performance, the distance from the front of the engine housing to the furthest surface of the window
should not exceed 2mm and the distance from the front of the engine housing to the nearest surface of the
window should not exceed 1mm.
If the window is required to be in a tilted position, the above distance requirements should be met and tilt
angle should ensure no reflections back into the lens.