Enter Setup
111 *
* Exit Setup
RT20
8
User
G
u
ide
Create a Batch Command
A batch command may contain a number of individual commands each of which is terminated by a
semicolon (;).
Command Structure: Command (+ “=” +
Parameter Value)
4 command syntaxes are described as below:
1. Syntax 1: Command
This syntax applies to most configuration situations.
Example:
Set the Baud Rate to 38400bps:
0100060
Enable the Sense Mode:
0302010
2.
Syntax 2: C “=” + Decimal Digi
t(s)
This syntax applies to the options/features programming which requires the entry of parameter value
(decimal), such as the Maximum/Minimum Length, Decode Session Timeout, Timeout between
Decodes (Same Barcode) and Sensitivity.
Example:
Set the Decode Session Timeout to 3000ms:
0313000=3000
Set the Sensitivity to (level) 10:
0312040=10
3.
Syntax 3: C “=” + Hexadecimal Digit(s) (e.g., 0x101
A, 0x2C03)
This syntax applies to the features/options programming like the Custom Prefix/Suffix, Terminating
Character Suffix, Code ID Suffix,
which requires the entry of parameter value (hexadecimal).
Example:
Set the Terminating Character Suffix to CR/LF:
0310000=0x0D0A
4.
Syntax 4: C “=” + Double Quotation Marks
For situations where the parameter value is visible character in Syntax 3, this syntax is also
appropriate.
Example:
Set the Custom Prefix to AUTO-ID:
0300000=“AUTO
-
ID”
Содержание RT208
Страница 1: ...RT208 User Guide RT208 OEM 2d Scan Engine User Guide RT208 User Guide...
Страница 21: ...Enter Setup 11 Exit Setup RT208 User Guide Spain Turkey_Q UK Austria Germany Belgium Russia Sweden Portugal...
Страница 147: ...137 RT208 User Guide Appendix 6 Digit Barcodes 0 9 0 5 1 6 2 7 3 8 4 9...
Страница 148: ...RT208 User Guide A F A B C D E F...