Chapter 2 Installation
General Requirements
ESD
ESD protection has been taken into account when designing the RT207 and the engine is shipped in ESD safe
packaging. Always exercise care when handling the engine outside its package. Be sure grounding wrist
straps and properly grounded work areas are used.
Dust and Dirt
The RT207 must be sufficiently enclosed to prevent dust particles from gathering on the lens and circuit
board. Dust and other external contaminants will eventually degrade the engine
’
s performance.
Ambient Environment
The following environmental requirements should be met to ensure good performance of the RT207:
Operating Temperature
-20
℃
~ 60
℃
Storage Temperature
-40
℃
~ 80
℃
Humidity
5% ~ 95% (non-condensing)
Thermal Considerations
Electronic components in the RT207 will generate heat during the course of their operation. Operating the
RT207 in continuous mode for an extended period may cause temperatures to rise on CIS and decoder chip.
Overheating can degrade image quality and affect scanning performance. Given that, the following
precautions should be taken into consideration when integrating the RT207.
Reserve sufficient space for good air circulation in the design.
Avoid wrapping the RT207 with thermal insulation materials such as rubber.