Description and Specification

4

Specifications

Maximum Switch Carrying Current

1.0 ampere per outlet

Maximum Switch Breaking Current

0.5 ampere per outlet

Inputs

Full duplex lines (busses): 6
Program Inputs: 2

Outputs (Two Channel)

User Station Strings: 12

Program Inputs

Impedance: 600 Ohms
Level: 0 dBm

Power Requirements

No external power required; power distributed from RTS Systems power supplies PS15 or PS31 connected at rear 
panel of SAP612.

Size (H x W x D)

1.72 in. (44mm) x 19 in.(483mm) x 8 in. (204mm)
Allow another four (4) inches (102mm) depth for cables on the rear panel.

Weight (Mass)

4.5 lbs. (2.05 kg)

Color

Grey, Fed. Std. #595A-26492

Specifications are subject to change without notice.

Содержание SAP612

Страница 1: ...Model SAP612 Source Assign Panel User Manual 9350 6872 00 Rev E April 2007...

Страница 2: ...mpany name address phone number a person to contact regarding the repair the type and quantity of equipment a description of the problem and the serial number s SHIPPING TO THE MANUFACTURER All shipme...

Страница 3: ...cifications 4 Reference View 5 Installation and Operation 7 Mechanical Installation 7 Electrical Installation 7 Power 7 Using TW Power Supplies 7 Using Other Power Sources 7 System Capacity 8 Intercom...

Страница 4: ......

Страница 5: ...e and exchange call signals A typical application is diagrammed in Figure 1 One 1 to three 3 TW power supplied such as Models PS8 or PS15 may be conveniently connected to the SAP612 to distribute powe...

Страница 6: ...on Strings 12 Program Inputs Impedance 600 Ohms Level 0 dBm Power Requirements No external power required power distributed from RTS Systems power supplies PS15 or PS31 connected at rear panel of SAP6...

Страница 7: ...5 Reference View Reference View FIGURE 2 SAP 612 Reference View...

Страница 8: ...Description and Specification 6...

Страница 9: ...owered user stations must have channel one assigned to the single powered buss For example if one PS8 is connected to the CH 1 2 INPUT all externally powered stations must have channel one permanently...

Страница 10: ...nector accommodates a pair of TW channels wired in the standard TW 2 wire configuration as follows Pin 1 Common low side of line Pin 2 Channel 1 Pin 3 Channel 2 Shielded cable is recommended for user...

Страница 11: ...f the panel Buss numbers 1 6 are identified to the right of each pair or switches Assign an intercom channel to a buss by setting the appropriate switch to the desired buss number All channels assigne...

Страница 12: ...Installation and Operation 10...

Страница 13: ...11 CHAPTER 3 Diagrams and Drawings AS6867 Assembly Drawing Connector Board Model SAP612 AS6866 Assembly Drawing Front Panel Switch Board SD6872 Schematic Diagram Source Assign Panel Model SAP612...

Страница 14: ...Diagrams and Drawings 12...

Страница 15: ...13 FIGURE 4 AS6867 Assembly Drawing Connector Board...

Страница 16: ...14 FIGURE 5 AS6866 Assembly Drawing Front Panel Switch Board...

Страница 17: ...15 FIGURE 6 SD6872 Schematic Diagram Source Assign Panel Model SAP612...

Отзывы: