RTS LCP-102 Скачать руководство пользователя страница 5

3.

PACKAGE CONTENTS

1

LCP-102 Level Control Panel

1

Power cord

1

User Manual

4.

INSTALLATION

4.1.

Location and Mounting

The LCP-102 occupies 2 rack spaces in a standard
19-inch equipment rack or bay, and it is 7.25 inches
(184.2 mm) deep behind the front panel (including the
rear panel connectors). There are no special ventilation
requirements. The LCP-102 should be mounted at or near
operator eye-level when standing or sitting to permit easy
access to the front panel controls and displays.

4.2.

Connections

System connections are summarized in Figure

2

Cable

diagrams are shown in Figures

3

to

8

Note that when

connecting a UIO-256 Frame along with the LCP-102,
you have a choice of two methods: either using the
LOOP connector of the LCP-102, or using a "Y" cable. If
you have several LCP-102's connected in a chain, you
can connect the UIO-256 to the LOOP connector of the
last LCP-102 in the chain, or you can insert it anywhere
in the chain with a "Y" cable. Whichever configuration
you use, you can also connect three additional UIO-256
Frames to the first UIO-256 in a ring configuration as
illustrated in the UIO-256 Manual.

5.

POWER-UP AND INITIAL SETTINGS

5.1.

Applying Power

Turn on the power switch on the back of each connected
LCP-102. During a normal power-up the alphanumeric
displays will first show asterisks ( **** ). After a few
moments, some assignments may appear in the displays
above selected keys (depending on whether or not
anything was previously assigned using the intercom
system configuration software). If there are currently no
assignments, the displays will show dashes. If the
LCP-102 that is connected to the intercom system cannot
establish communication with the intercom system, all
LCP-102 displays will continue to show asterisks. In this
case, check the cable from the first LCP-102 to the
intercom system and verify that the intercom system is
operational. If more than one LCP-102 is used, you will

have to set the addresses using the programming menus
as described below.

5.2.

Programming Menus

The LCP-102 programming menus are accessed using the
ADDRESS KEY. The menus are summarized in Table

1

The following paragraphs describe the use of the menus.

5.3.

Setting the Panel Address

Before programming any assignments, each LCP-102
should be set to a unique panel address as follows:

Each programming step should be performed within
about 10 seconds. Otherwise, the LCP-102 will
automatically cancel the procedure.

1.

Rotate the ADDRESS KEY to display SERVICE,
then click the key once. DIMMER will appear in the
menu display.

2.

Rotate the ADDRESS KEY to display SET ADDR,
then click the control. ADDR 1 will display.

3.

For the first LCP-102, select ADDR 1, then click the
ADDRESS KEY. This will store the setting, and all
displays will show asterisks for a few moments.
Then, all displays will show dashes.

4.

Double-click the ADDRESS KEY control to exit
programming mode when finished. Otherwise, the
LCP-102 will automatically exit after about 10
seconds.

The address setting is retained in the LCP-102
memory when power is removed.

5.

Repeat the above steps for any additional LCP-102's,
selecting ADDR 2 for the second LCP-102 and so
forth.

User Manual, LCP-102 Level Control Panel

5

PAGE SEL MENU ITEMS

SERVICE MENU ITEMS

PAGE 1

DIMMER

PAGE 2

SET ADDR

PAGE 3

SET MODE

PAGE 4

VER

Table 1. The LCP-102 Programming Menus

Содержание LCP-102

Страница 1: ...USER MANUAL Model LCP 102 Level Control Panel ADAM ADAM CS and ZEUS Intercom Systems 9350 7623 000 Rev B 04 2006 ADDRESS KEY IN PUT LEVEL OUTPUT LEVEL LCP 1 02 TM TRIM S PAP CDP...

Страница 2: ...Service 800 553 5992 Please include a note in the box which supplies the company name address phone number a person to contact regarding the repair the type and quantity of equipment a description of...

Страница 3: ...ion Changes 8 LIST OF FIGURES Figure 1 LCP 102 Reference View 4 Figure 2 Typical connection methods for the LCP 102 9 Figure 3 Interconnect cable from a Zeus or ADAM Intercom System to the LCP 102 10...

Страница 4: ...n select the program input source and set its level for each of 64 IFB s In CDP mode you can assign up to 64 intercom ports to any combination of party lines and then adjust the listen level for each...

Страница 5: ...ays will show dashes If the LCP 102 that is connected to the intercom system cannot establish communication with the intercom system all LCP 102 displays will continue to show asterisks In this case c...

Страница 6: ...the following paragraphs that apply to the currently selected panel mode 6 3 TRIMS Mode Assignments and Operation 6 3 1 General In TRIMS mode you assign individual ports of the intercom system to disp...

Страница 7: ...r of the assignment s controls The display will go blank Click the control once more and the display will return to showing dashes indicating no assignment 6 4 3 PAP Mode Operation To change the progr...

Страница 8: ...panel mode and current setup page are saved in the LCP 102 and will be retained if the power is turned off All display assignments and level settings are uploaded to the intercom system and become pa...

Страница 9: ...56 LOOP DATA J2 CONNECTIONS FOR A SINGLE LCP 102 OR MULTIPLE LCP 102 S TWO METHODS FOR CONNECTING A UIO 256 WITH THE LCP 102 UP TO THREE MORE UIO 256 FRAMES MAY BE CONNECTED TO THE FIRST UIO 256 IN A...

Страница 10: ...P Male 7 2 1 TO FIRST LCP 102 LOOP 7 2 1 TO SECOND LCP 102 DATA DE 9S Female Figure 5 Cable to interconnect two LCP 102 s All intercom systems DE 9S Female 6 1 2 TO ADAM CS J902 7 2 1 TO LCP 102 DATA...

Отзывы: