DV3066
22
ADJUSTMENT
Transmitter section
Item Condition
Measurement Adjustment
Specifications
/Remarks
Test equipment
Terminal
Parts
Method
7. VOX 1
Writing
TEST CH: Center
AG: 1KHz/5mV
Power meter
Deviation meter
Oscilloscope
AG
AF VTVM
ANT
SP/MIC
connector
Programming
Software:
QPS-3066
8. VOX 10
Writing
TEST CH: Center
AG: 1kHz/15mV
9. DCS
Balance
Adjust
TEST CH: Center
Low
High
LPF: 3kHz
HPF:OFF
PTT:ON
ANT
Adjust the waveform
10. CTCSS
Deviation
Adjust
0.75kHz
±100Hz
11. DCS
Deviation
Adjust
[Wide]
TEST CH: Center
Low
High
LPF: 3kHz
HPF:OFF
PTT:ON
0.75kHz
±100Hz
12.
DTMF
deviation
[Wide]
TEST
CH : center
LPF:15kHz
HPF:OFF
PTT:ON
3kHz
±100Hz
13. Battery
Detection
Warning
BATT terminal voltage:6.0V
Power meter
DVM
ANT
BATT
terminal
test
The transceiver
cannot transmit.
14. Battery
Detection
Check
BATT terminal voltage:6.3V
PTT: ON
Check
Blinking of LED
BATT terminal voltage:7.4V
PTT: ON
No blinking of
LED
Receiver Section
Item Condition
Measurement Adjustment
Specifications
/Remarks
Test equipment
Terminal
Parts
Method
1. Sensitivity
check
[Wide]
TEST CH: Center
Low
High
SSG output: -120dBm(0.22
μ
V)
SSG MOD: 3.0kHz
SSG
DVM
Oscilloscope
AG
AF VTVM
ANT
Check
12dB SINAD or
more
[Narrow]
TEST CH: Center
SSG output: -119dBm(0.25
μ
V)
SSG MOD: 1.5kHz
Содержание DV-3066
Страница 25: ...24 DV3066 PC board views...
Страница 26: ...25 DV3066 PC board views...