RTR Energia 12kVAr Скачать руководство пользователя страница 18

 

                       

TECHNICAL USER´S MANUAL

 

 
 

17 

Thyristor modules  

 

6 – Warranty, Terms and Conditions 

These modules are warranted against manufacturing defects for 1 (one) year. The modules 

are  out  of  warranty  in  case  of  user  error,  use  not  in  accordance  with  recommended  practice 
presented in this manual, internal circuits are tampered with and/or the cover is removed.  

The manufacturer is not responsible for: 
 

 

Any  costs  resulting  from  a  failure  if  the  installation,  setup,  repair,  alteration,  or  ambient 
conditions  of  the  module  do  not  follow  the  requirements  specified  in  the  documentation 
delivered with the module and other relevant documentation. 

 

Modules subjected to misuse, negligence, or accident. 

In  no  event  shall  the  manufacturer,  its  suppliers  or  subcontractors  be  liable  for  special, 

indirect,  incidental,  or  consequential  damages,  losses  or  penalties.  If  you  have  any  questions 
concerning  your  thyristor  modules,  please  contact  the  local  distributor  or  RTR  Energía.  The 
technical data, information and specifications are valid at the time of printing. The manufacturer 
reserves the right to make modifications without prior notice. 

 

7 – Contact Information 

RTR Energía, S.L. 

Address:

    C/ Gavilanes, 11Bis 

                    Pol. Ind. Pinto – Estación 
                    28320 pinto (Madrid) – SPAIN 

Phone

: +34 916 916 612 

Fax:

 +34 916 912 257 

E-mail:

 [email protected] 

Web:

 

www.rtr.es

 

 

 

Содержание 12kVAr

Страница 1: ...Ind Pinto Estaci n 28320 Pinto Madrid ESPA A Tel 34 916 916 612 Fax 34 916 912 257 info rtr es www rtr es Microprocessor Controlled Capacitor Switching Thyristor Modules Technical User s Manual Date 0...

Страница 2: ...ratings specified in the technical specifications Do not touch the modules with bare and or wet hands while it is on Make sure that the power is turned off when cleaning Use a dry cloth to clean the m...

Страница 3: ...1 1 General Description 1 2 Application Areas 2 Technical Specifications 3 Setup 3 1 Prerequisites for Setup 3 2 Installation 3 3 Wiring Diagrams 3 4 Ready for Start Up 3 5 Alarms and Indicators 4 Te...

Страница 4: ...module internal memory The modules can operate with or without a detuned filter reactor The modules protect detuned filter reactors against overheating through their external thermostat connections Th...

Страница 5: ...h connecting the ground cable to the auxiliary power supply connector Electrical connections should follow the wiring diagrams provided in Figures 3 3 3 6 in the Wiring Diagrams section Superfast elec...

Страница 6: ...be equipped with a discharging High power resistors or discharge reactors are recommended to increase switching speed and frequency Discharge resistors need to be selected carefully to achieve desired...

Страница 7: ...S MANUAL 6 Thyristor modules Figure 3 1 The effect of discharge resistance on discharge time for 7 189Hz and 14 134Hz detuned reactor PFC with three discharge resistors 7 rates may be used if no react...

Страница 8: ...5 25kVAr 63 NH AC 690 25 50kVAr 125 NH AC 690 50 80kVAr 200 NH AC 690 80 MITIGATING HIGH di dt When the thyristors are triggered the current is initiated at the gate cathode junction The current sprea...

Страница 9: ...ter reactors for 12kVAr 25kVAr 50kVAr and 80kVAr modules are presented in Figures 3 3 3 6 Figure 3 3 Recommended wiring diagram for 12kVAr and 25kVAr modules with a detuned filter reactor and a discha...

Страница 10: ...r modules Figure 3 4 Recommended wiring diagram for 12kVAr and 25kVAr modules without a detuned filter reactor and with a discharge reactor Connection terminals wiring diagrams and structures of 12kVA...

Страница 11: ...istor modules Figure 3 5 Recommended wiring diagram for 50kVAr and 80kVAr modules with a detuned filter reactor and a discharge reactor Connection terminals wiring diagrams and structures of 50kVAr an...

Страница 12: ...r modules Figure 3 6 Recommended wiring diagram for 50kVAr and 80kVAr modules without a detuned filter reactor and with a discharge reactor Connection terminals wiring diagrams and structures of 50kVA...

Страница 13: ...ults The function of each LED is described as follows POWER LED red Informs the user that the module is powered up FAULT LED red Informs the user of internal faults If the module detects a misconnecti...

Страница 14: ...TECHNICAL USER S MANUAL 13 Thyristor modules Figure 4 1 12kVAr and 25kVAr modules technical drawings...

Страница 15: ...TECHNICAL USER S MANUAL 14 Thyristor modules Figure 4 2 50kVAr and 80kVAr modules technical drawings...

Страница 16: ...is used without wiring the thermostat connections Otherwise the module will evaluate this situation as a reactor thermal fault and will not let the user switch on the capacitors FAULT LED is blinking...

Страница 17: ...ED displays operating status of the module If this LED is not lit up then one of the following four situations must be true 1 System is not powered up 2 Trigger signal is not being received 3 Capacito...

Страница 18: ...he documentation delivered with the module and other relevant documentation Modules subjected to misuse negligence or accident In no event shall the manufacturer its suppliers or subcontractors be lia...