8.50
[215,9]
6.00
[152,4]
.07
[1,7]
1.72
[43,7]
1.98
[50,3]
6.39
[162,4]
FRONT PANEL REMOVED
FOR CLARITY
XP-6s Dimensions
REMOTE TECHNOLOGIES INC.
SHAKOPEE, MN 55379
USB
RESET
STATUS
IR OUTPUT ADJUST
SENSE
COMM
POWER / IR
PORT 1
PORT 2
PORT 3
PORT 4
PORT 5
PORT 6
RELAYS
TRIGGERS
POWER
NET
LINK
SIGNAL
IN
HIGH OUT
PROG PORT
3
2
1
3
2
1
3
2
1
Advanced Control Processor
Model XP-6s
RS-232 (1)
POWER / IR
SENSE
IR / SERIAL / SENSE
EXPANSION
+12VDC, 1A
MULTI-PURPOSE I/O PORTS
RS-232 (2)
ETHERNET
RS-232 (3)
TRIGGERS
RELAYS
RTI COM
POWER
1 2 3
1 2 3
1
2
3
GND
INPUT
HIGH OUT
A B
A B A B
4
1
2
3
5
6
+12VDC
3-24VDC
12V,100mA MAX
3A@30VDC MAX
GND
GND
8.50
[215,9]
6.00
[152,4]
.07
[1,7]
1.72
[43,7]
1.98
[50,3]
6.39
[162,4]
FRONT PANEL REMOVED
FOR CLARITY
XP-6s Dimensions
REMOTE TECHNOLOGIES INC.
SHAKOPEE, MN 55379
USB
RESET
STATUS
IR OUTPUT ADJUST
SENSE
COMM
POWER / IR
PORT 1
PORT 2
PORT 3
PORT 4
PORT 5
PORT 6
RELAYS
TRIGGERS
POWER
NET
LINK
SIGNAL
IN
HIGH OUT
PROG PORT
3
2
1
3
2
1
3
2
1
Advanced Control Processor
Model XP-6s
RS-232 (1)
POWER / IR
SENSE
IR / SERIAL / SENSE
EXPANSION
+12VDC, 1A
MULTI-PURPOSE I/O PORTS
RS-232 (2)
ETHERNET
RS-232 (3)
TRIGGERS
RELAYS
RTI COM
POWER
1 2 3
1 2 3
1
2
3
GND
INPUT
HIGH OUT
A B
A B A B
4
1
2
3
5
6
+12VDC
3-24VDC
12V,100mA MAX
3A@30VDC MAX
GND
GND
DB-9
Pin Signal
Signal
Name
Description
1
DCD
Carrier Detect
2
RXD
Receive Data
3
TXD
Transmit Data
4
DTR
Data Terminal Ready
5
GND
Signal Ground
6
DSR
Data Set Ready
7
RTS
Request To Send
8
CTS
Clear To Send
9
NC
Not Connected
RJ-45
(XP-6s RS-232 Output)
Pin Signal
Signal
Name
Description
1
DSR
Data Set Ready
2
DCD
Carrier Detect
3
DTR
Data Terminal Ready
4
GND
Signal Ground/Common
5
RXD
Receive Data
6
TXD
Transmit Data
7
CTS
Clear To Send
8
RTS
Request To Send
DB-9 - RJ45 ADAPTOR PINOUT
PROGRAMMING THE XP-6s
The XP-6s must be programmed to operate. All programming is done using RTI’s
Integration Designer
®
software and is downloaded using the USB
Programming Port located on front of XP-6s or via Ethernet.
UPDATING FIRMWARE
It is highly recommended that this and all RTI products have the latest firmware installed. The firmware can be found in the Dealer section of the RTI
website (www.rticorp.com). Install the firmware using the USB Programming Port located on the front of XP-6s.
MPIO PORTS - Control via Infrared, Sensing and RS-232 (One-way)
Each IR output can drive up to
four emitters directly. More than
four emitters require an amplified
connecting block.
Direct to IR Port
Single or Dual
IR Emitters
CM-232 Communication Module
(RS-232 One-way)
Voltage From
Power Supply
IR Emitter
Equipment with switched outlet
or voltage trigger output
IR Connecting Block
The XP-6s is capable of two-way control using RS-232 communication via three RJ-45
output ports using standard Cat-5 cable with RJ-45 termination (568B). The XP-6s
ships with three RJ-45 (female) to DB-9 (male) adapters.
IMPORTANT NOTE: RS-232 communication cabling should be limited to 50 feet (16m)
depending on baud rate.
Security
Cat-5
Adapter
HVAC
Lighting
SENSE INPUTS / RELAY-TRIGGER OUTPUTS
Sense inputs and relay-trigger modes are configured within
Integration
Designer
®
.
Access
Sensor
SENSE INPUT
Upon sensing contact closure events can be automatically triggered such
as a macro or command.
Connect conductors from the source device to a sense input (1-3)
and the ground (GND) terminal.
TRIGGER OUTPUTS
The voltage triggers output 12VDC @100mA.
Connect the positive lead to a trigger output (1-3) and the negative
lead to the ground (GND) terminal.
RELAYS
Relays cause a dry contact closure. All relays are Normally Open when
not energized, and may be programmed to behave Normally Closed (as
long as power is applied to
the XP-6s).
Connect the A and B contact terminals of a relay to the device.
+
-
INFRARED EMITTERS
The multi-purpose I/O ports on the XP-6s are compatible with industry
standard infrared emitters and infrared repeating systems. Each output port is
capable of driving up to four infrared emitters directly. The use of more than
four infrared emitters requires the addition of an amplified connecting block. A
connecting block can be wired up to 1000 feet away from the XP-6s using #22
AWG (minimum) wire.
INFRARED OUTPUT GAIN ADJUSTMENT
The IR output gain can be separately adjusted for each of the six output
ports. The XP-6s is shipped with the IR gain set to the optimum level for
most equipment, and it should only need to be adjusted if the attached
equipment is not responding reliably. If adjustment is needed, rotate the IR
output controls on the front of the XP-6s clockwise for higher output power, or
counter-clockwise for lower output power.
NOTE: The IR output feedback LEDs located on the front of the XP-6s will
illuminate when any IR code is delivered out of a port.
VPS-1 SENSOR MODULE
The multi-purpose I/O ports on the XP-6s are compatible with RTI power
sensing modules (e.g. VPS-1). Follow the guide included with the modules
for installation instructions, and follow the instructions in the
Integration
Designer
®
software for programming details.
RS-232 COMMUNICATION MODULES (CM-232)
The multi-purpose I/O ports on the XP-6s are compatible with RTI RS-232
communication modules (e.g. CM-232). Follow the guide included with
the modules for installation instructions, and follow the instructions in the
Integration Designer
®
software for programming details.
RS-232 PORTS
Installation & Operation
Shades
Screen Lift
+ -
8.50
[215,9]
6.00
[152,4]
.07
[1,7]
1.72
[43,7]
1.98
[50,3]
6.39
[162,4]
FRONT PANEL REMOVED
FOR CLARITY
XP-6s Dimensions
REMOTE TECHNOLOGIES INC.
SHAKOPEE, MN 55379
USB
RESET
STATUS
IR OUTPUT ADJUST
SENSE
COMM
POWER / IR
PORT 1
PORT 2
PORT 3
PORT 4
PORT 5
PORT 6
RELAYS
TRIGGERS
POWER
NET
LINK
SIGNAL
IN
HIGH OUT
PROG PORT
3
2
1
3
2
1
3
2
1
Advanced Control Processor
Model XP-6s
RS-232 (1)
POWER / IR
SENSE
IR / SERIAL / SENSE
EXPANSION
+12VDC, 1A
MULTI-PURPOSE I/O PORTS
RS-232 (2)
ETHERNET
RS-232 (3)
TRIGGERS
RELAYS
RTI COM
POWER
1 2 3
1 2 3
1
2
3
GND
INPUT
HIGH OUT
A B
A B A B
4
1
2
3
5
6
+12VDC
3-24VDC
12V,100mA MAX
3A@30VDC MAX
GND
GND
+
-