background image

8.50

[215,9]

6.00

[152,4]

.07

[1,7]

1.72

[43,7]

1.98

[50,3]

6.39

[162,4]

FRONT PANEL REMOVED

FOR CLARITY

XP-6s Dimensions

REMOTE TECHNOLOGIES INC.

SHAKOPEE, MN 55379

USB

RESET

STATUS

IR OUTPUT ADJUST

SENSE

COMM

POWER / IR

PORT 1

PORT 2

PORT 3

PORT 4

PORT 5

PORT 6

RELAYS

TRIGGERS

POWER

NET

 LINK

SIGNAL

 IN

HIGH OUT

PROG PORT

3

2

1

3

2

1

3

2

1

Advanced Control Processor

Model XP-6s

RS-232 (1)

POWER / IR

SENSE

IR / SERIAL / SENSE

EXPANSION

+12VDC, 1A

MULTI-PURPOSE I/O PORTS

RS-232 (2)

ETHERNET

RS-232 (3)

TRIGGERS

RELAYS

RTI COM

POWER

1 2 3

1 2  3

1

2

3

GND

INPUT

HIGH OUT

A B

A B A B

4

1

2

3

5

6

+12VDC

3-24VDC

12V,100mA MAX

3A@30VDC MAX

GND

GND

8.50

[215,9]

6.00

[152,4]

.07

[1,7]

1.72

[43,7]

1.98

[50,3]

6.39

[162,4]

FRONT PANEL REMOVED

FOR CLARITY

XP-6s Dimensions

REMOTE TECHNOLOGIES INC.

SHAKOPEE, MN 55379

USB

RESET

STATUS

IR OUTPUT ADJUST

SENSE

COMM

POWER / IR

PORT 1

PORT 2

PORT 3

PORT 4

PORT 5

PORT 6

RELAYS

TRIGGERS

POWER

NET

 LINK

SIGNAL

 IN

HIGH OUT

PROG PORT

3

2

1

3

2

1

3

2

1

Advanced Control Processor

Model XP-6s

RS-232 (1)

POWER / IR

SENSE

IR / SERIAL / SENSE

EXPANSION

+12VDC, 1A

MULTI-PURPOSE I/O PORTS

RS-232 (2)

ETHERNET

RS-232 (3)

TRIGGERS

RELAYS

RTI COM

POWER

1 2 3

1 2  3

1

2

3

GND

INPUT

HIGH OUT

A B

A B A B

4

1

2

3

5

6

+12VDC

3-24VDC

12V,100mA MAX

3A@30VDC MAX

GND

GND

DB-9 

Pin    Signal  

Signal 

 

Name  

Description   

 

1  

DCD  

Carrier Detect

2  

RXD  

Receive Data

3  

TXD  

Transmit Data

4  

DTR  

Data Terminal Ready

5  

GND  

Signal Ground

6  

DSR  

Data Set Ready

7  

RTS  

Request To Send

8  

CTS  

Clear To Send

9  

NC  

Not Connected

RJ-45 

 (XP-6s RS-232 Output)

   

Pin    Signal  

Signal 

 

Name  

Description 

1  

DSR 

Data Set Ready

2  

DCD  

Carrier Detect

3  

DTR  

Data Terminal Ready

4  

GND  

Signal Ground/Common

5  

RXD  

Receive Data

6  

TXD  

Transmit Data

7  

CTS  

Clear To Send

8  

RTS  

Request To Send

DB-9 - RJ45 ADAPTOR PINOUT

PROGRAMMING THE XP-6s 

The XP-6s must be programmed to operate. All programming is done using RTI’s 

Integration Designer

®

 software and is downloaded using the USB 

Programming Port located on front of XP-6s or via Ethernet. 

UPDATING FIRMWARE

It is highly recommended that this and all RTI products have the latest firmware installed. The firmware can be found in the Dealer section of the RTI 

website (www.rticorp.com). Install the firmware using the USB Programming Port located on the front of XP-6s.

MPIO PORTS - Control via Infrared, Sensing and RS-232 (One-way)

Each IR output can drive up to 

four emitters directly. More than 

four emitters require an amplified 

connecting block.

Direct to IR Port

Single or Dual
IR Emitters 

 

CM-232 Communication Module

(RS-232 One-way)

Voltage From 

Power Supply

IR Emitter

Equipment with switched outlet

or voltage trigger output

IR Connecting Block

The XP-6s is capable of two-way control using RS-232 communication via three RJ-45 

output ports using standard Cat-5 cable with RJ-45 termination (568B). The XP-6s 

ships with three RJ-45 (female) to DB-9 (male) adapters. 

IMPORTANT NOTE: RS-232 communication cabling should be limited to 50 feet (16m)

depending on baud rate.

Security

Cat-5

Adapter

HVAC

Lighting

SENSE INPUTS / RELAY-TRIGGER OUTPUTS

Sense inputs and relay-trigger modes are configured within 

Integration 

Designer

®

.

Access 

Sensor

SENSE INPUT

Upon sensing contact closure events can be automatically triggered such 

as a macro or command.

        Connect conductors from the source device to a sense input (1-3) 

and the ground (GND) terminal.

TRIGGER OUTPUTS

The voltage triggers output 12VDC @100mA.  

        Connect the positive lead to a trigger output (1-3) and the negative 

lead to the ground (GND) terminal.

RELAYS

Relays cause a dry contact closure. All relays are Normally Open when 

not energized, and may be programmed to behave Normally Closed (as 

long as power is applied to

 

the XP-6s).

        Connect the A and B contact terminals of a relay to the device. 

+

-

INFRARED EMITTERS

The multi-purpose I/O ports on the XP-6s are compatible with industry 

standard infrared emitters and infrared repeating systems. Each output port is 

capable of driving up to four infrared emitters directly. The use of more than 

four infrared emitters requires the addition of an amplified connecting block. A 

connecting block can be wired up to 1000 feet away from the XP-6s using #22 

AWG (minimum) wire. 

INFRARED OUTPUT GAIN ADJUSTMENT

The IR output gain can be separately adjusted for each of the six output 

ports. The XP-6s is shipped with the IR gain set to the optimum level for 

most equipment, and it should only need to be adjusted if the attached 

equipment is not responding reliably. If adjustment is needed, rotate the IR 

output controls on the front of the XP-6s clockwise for higher output power, or 

counter-clockwise for lower output power.
NOTE:  The IR output feedback LEDs located on the front of the XP-6s will 

illuminate when any IR code is delivered out of a port. 

VPS-1 SENSOR MODULE

The multi-purpose I/O ports on the XP-6s are compatible with RTI power 

sensing modules (e.g. VPS-1). Follow the guide included with the modules 

for installation instructions, and follow the instructions in the 

Integration 

Designer

®

 software for programming details.

RS-232 COMMUNICATION MODULES (CM-232)

The multi-purpose I/O ports on the XP-6s are compatible with RTI RS-232 

communication modules (e.g. CM-232). Follow the guide included with 

the modules for installation instructions, and follow the instructions in the 

Integration Designer

®

 software for programming details.

RS-232 PORTS

Installation & Operation

Shades

Screen Lift

+ -

8.50

[215,9]

6.00

[152,4]

.07

[1,7]

1.72

[43,7]

1.98

[50,3]

6.39

[162,4]

FRONT PANEL REMOVED

FOR CLARITY

XP-6s Dimensions

REMOTE TECHNOLOGIES INC.

SHAKOPEE, MN 55379

USB

RESET

STATUS

IR OUTPUT ADJUST

SENSE

COMM

POWER / IR

PORT 1

PORT 2

PORT 3

PORT 4

PORT 5

PORT 6

RELAYS

TRIGGERS

POWER

NET

 LINK

SIGNAL

 IN

HIGH OUT

PROG PORT

3

2

1

3

2

1

3

2

1

Advanced Control Processor

Model XP-6s

RS-232 (1)

POWER / IR

SENSE

IR / SERIAL / SENSE

EXPANSION

+12VDC, 1A

MULTI-PURPOSE I/O PORTS

RS-232 (2)

ETHERNET

RS-232 (3)

TRIGGERS

RELAYS

RTI COM

POWER

1 2 3

1 2  3

1

2

3

GND

INPUT

HIGH OUT

A B

A B A B

4

1

2

3

5

6

+12VDC

3-24VDC

12V,100mA MAX

3A@30VDC MAX

GND

GND

+

-

Отзывы: