background image

 
 

 

12 

MONTHLY INSPECTION:

 

 

ONLY CARRY OUT WHEN INSTALLATION IS COOL AND AT A STANDSTILL 

WITH THE POWER CORD DISCONNECTED OR THE MAIN SWITCH OFF 

 

This check may only be carried out by skilled mechanics. Observe the safety very carefully, 
the enclosure must be removed and rotating parts will be accessible. 
 
A: 

Check the wear of the V-belts, replace if necessary. 

 
B: 

Lubricate latches and padlock and check their functioning. 

 
C: 

Preserve the compressor when it has been at a standstill for a longer period of time.  

 

(L

ubricate the compressor’s rotor with oil to prevent corrosion.) 

 

To carry out the following inspections it is necessary to start the installation without 
enclosure. Please note the dangers that can occur as a result of access to:  
- hot parts as compressor and silencer (150 °C)  
- rotating parts such as the transmission and the fan  
- high sound levels (> 85 dB)  

 

HEARING PROTECTION OBLIGATED!! 

 
D: 

Check the functioning of the safety valve.  
Air pressure measured at the discharge flange of the compressor may not exceed a 
maximum gauge pressure of 2.5.  

 

Potential pressure loss between compressor and silo tank of 0.2 up to 0.3 bar. 

 
E: 

Check flanges/packing, rubber compensators etc. in the enclosure for air leakages to 
avoid loosening of the insulation material and overheating. 

 
F: 

Check pipes, cooler and connection joints for oil leakage. 

 
 
 

HALFYEARLEY INSPECTION:

 

  

 

ONLY CARRY OUT WHEN INSTALLATION IS COOL AND AT A STANDSTILL 

WITH THE POWER CORD DISCONNECTED OR THE MAIN SWITCH OFF 

 

This check may only be carried out by skilled mechanics. Observe the safety very carefully, 
the enclosure must be removed and rotating parts will be accessible. 
 
A: 

Change the lubricating oil at least twice a year (oil type SAE 10W40). 

 
B: 

Replace oil filter. 

 
C: 

Demount the non-return valve installed in the discharge silencer and check for proper 
functioning also check the packings and replace if necessary. 

 

NOTE: 

 

The operating instructions provided by the compressor manufacturer should be 
read carefully. 

 

 

Содержание SiloKing 1100 LS

Страница 1: ...INSTRUCTION AND OPERATING MANUAL RTI Compressor unit with electric motor SiloKing 1100 LS These pictures are only examples...

Страница 2: ...interference free operation and to achieve longevity Repairs maintenance or conversion work shall only be carried out by authorised trained and qualified personnel that are familiar with the current...

Страница 3: ...3 Operating safety conscious 2 4 Safety instructions operator 2 5 Modifications and repairing spare parts 2 6 Modifications unit 3 Commissioning 3 1 Set up 3 2 Operating elements and monitoring gauges...

Страница 4: ...ontact details Please mention the PO number when contacting us by phone or mail You will find the PO number on the type plate of the installation Telephone number 0031 544 377050 Fax 0031 544 376499 E...

Страница 5: ...oil free Power 52 kW at 2 bar and 2930 rpm Driven by 55 75 kW electrical motor Technical data electrical motor Power 55 kW 400 Volt 75 kW 400 Volt Manufacturer Elsto Elsto Type 250 L 2 A 280 L 4 B Bu...

Страница 6: ...sure that the distribution pipes and pipe connections are of the correct size and suitable for the respective operating pressure Install the unit in a place where the ambient air is as cool and clean...

Страница 7: ...ection Important Any work on the compressor such as operation and maintenance shall only be carried out by authorised skilled and qualified personnel who are familiar with the applicable safety regula...

Страница 8: ...ulations shall be applicable Any special official codes and regulations particularly safety regulations applicable to your operation in view of the local conditions shall be observed likewise In the e...

Страница 9: ...air filter 3 3 Start up motor compressor Provide for electrical power connection Check phase circuit direction of rotation control light green ok red set main switch to 2 Press start button green Chec...

Страница 10: ...r if necessary see operating instructions for compressor chapter Maintenance Air filter indicator Negative pressure is indicated on the air filter indicator of the compressor unit Important If the 65...

Страница 11: ...To prevent overheating in the enclosure the valve at the silo tank must blow off before the compressor valve does blow off pressure 2 5 bar D Pay attention to any unusual sounds or peculiarities near...

Страница 12: ...D Check the functioning of the safety valve Air pressure measured at the discharge flange of the compressor may not exceed a maximum gauge pressure of 2 5 Potential pressure loss between compressor an...

Страница 13: ...he sound cover only when the compressor is at standstill Caution Burning hazard due to hot machine parts Wear protective gloves 4 2 V belt drive Check the tension of the V belts and asses the wear of...

Страница 14: ...Drive speed to high Adjust drive speed Defective non return valve Replace non return valve Safety valve does not blow off Check safety valve Negative pressure gauge reading 65 mbar Suction filter clog...