![RTI RHS780 Скачать руководство пользователя страница 5](http://html1.mh-extra.com/html/rti/rhs780/rhs780_manual_1497717005.webp)
Page 5 of 5
Function Tests
RECOVER REFRIGERANT FROM HOSES TO TEST RECYCLE PROCESS:
1. Press
[
_
_
_
_
]
key ONE time. The display will show
WEIGHT = XX.X LB - RECYCLE?
.
2. Press [
ENTER]
key. The display will show
RECYCLE HOLD - TIME 02 MIN
. The default minimum time is two
minutes. Do not make any change.
3. Press [
ENTER]
key. Display will show
CHECK HOSES - START?
.
4. Press
[ENTER]
key. Display will show
WEIGHT = XX.X LB - COMPRESSOR ON
. The refrigerant in the high and
low side hoses will be recovered. The high and low pressure gauges will show the pressure decrease until a
vacuum is reached. The compressor will shut off and the display will show
WEIGHT = XX.X LB - COMPRESSOR
OFF
. The two minute recycle hold timer will start. The display will show
AMOUNT RECYCLED = XX.X LB
after
the two minutes has elapsed.
5. Press
[ENTER]
key to end the process.
CONGRATULATIONS
THANKS
Performing these tests demonstrated that the RHS780 is operating correctly.
NOW IT’S TIME TO MAKE SOME MONEY
The best suggestion we can offer is that you quickly browse the Operation Manual before using
the RHS780 to perform an actual A/C service. Then, during the first few uses, refer to the
Operation Manual and follow the instructions as each process is performed.
The RHS780 was carefully designed to be intuitive to use. The display screens prompt for input
as required and always ask for confirmation before starting a process.
It’s very important that you follow the Operation Manual the first few times to become familiar with
the techniques of using the RHS780 for A/C service. Then you will find that the display screens
will give you adequate prompts for future use.
4075 East Market Street
York, Pennsylvania 17402
Phone: 800-468-2321
Fax: 717-755-8304
E-mail: [email protected]