background image

 

13

 

C  A L  I  B R A T  I  O N    R E  J  E C T E D
R E C A L  I  B R A T E    U N  I  T    O R
C  A L  L    F O R    S E R V  I  C E     

                      C O N  T  I  N U E ?

 

P E R F O R M    C A L  I  B R A T  I  O N

                                   
                                   

S E L E C T    Y E S    O R    N O     

 

C O N N E C T   C Y L  I  N D E  R    T O
H I G H  S I D E  H O S E  A N D
O P E N    V A 

     

     

                      C O N  T  I  N U E ?

 

C H A R G E    I  N    P R O C E S S   

A M T    C H G =    #  #  .  #  #    K G   

                                   
                      C O N  T  I  N U E ?

 

C  A L  I  B R A 

T I 

N  M 

N    

W E  I  G H  T    O N                   

                     

         

   

                      C O N  T  I  N U E ?

 

C  A L  I  B R A T  I  O N    M  A 

X    

W E  I  G H  T    O N                   

                     

         

   

                      C O N  T  I  N U E ?

 

C  A L  I  B R A T  I O N    C O M P L E T E

E  

T      

                     

         

   

                      C O N  T  I  N U E ?

 

P E R F O R M  

I  N P U T  / O U T P U T

D I A G N O S  T  I  C  S  ?             

                     

         

   

S E L E C T    Y E S    O R    N O     

 

U S E   

   

  

T  O    C  H  A N  G  E   

S E L E C T E D    O U T P U T       
S T A R  T    T O G G L  E  S    O N  & O F F

P  T 

O  E 

D        

 

 

U S E   

   

  

T  O    C  H  A N  G  E   

S E L E C T E D    I  N P U T         
S T A R  T    T O G G L  E  S    O N  & O F F

P  T 

O  E 

D        

 

This screen will display if the weight scale is not in 
calibration. Perform the Calibration Procedure. Press 

START

 key. 

 

Press 

YES

 key if a calibration is required. Otherwise, 

press 

NO

 key. 

 

If 

YES

 key was pressed, this screen will display. 

Connect the red high side hose of the RHS980 to the 
vapor port of a refillable DOT cylinder. Open the valve 
on the cylinder. Press 

START

 key. Refrigerant will be 

transferred from the RHS980 internal cylinder into the 
externally connected DOT cylinder. 

This screen will display an increasing amount as 
refrigerant is transferred to the DOT cylinder. Press 

START

 key when the amount does not increase any 

more. 

 

This screen indicates the weight scale is reading a 
minimum weight since the charge cylinder is empty. 
Press 

START

 key. 

 

This screen prompts for maximum weight. Place the 
calibration weights on top of the RHS980 charge 
cylinder. The weight scale will now read a maximum 
weight. Press 

START

 key. Call RTI to order weights. 

 

The weight scale is now calibrated. Remove the 
calibration weights. Press 

START

 key. 

 

Inputs and outputs of devices in the RHS980 can be 
checked for diagnostic purposes. Press 

YES

 key.  

 

 

Press 

 or 

 key to select various outputs. The 

output identification number will display on the screen. 
For a selected output, press the 

START

 key to toggle 

it on and off. Press 

STOP

 key to advance to next 

screen. 

 

Press 

 or 

 key to select various inputs. The input 

identification number will display on the screen. For a 
selected input, press the 

START

 key to toggle it on 

and off and display units. Press 

STOP

 key to advance 

to next screen. 

 

 

Содержание RHS 980

Страница 1: ...RHS 980 Operation Manual RTI Technologies Inc 10 Innovation Drive York Pennsylvania 17402 USA Phone 717 840 0678 Toll Free 800 468 2321 Web site www rtitech com Manual P N 035 81361 00...

Страница 2: ...ou have purchased one of the finest Recovery Recycling and Charging Machines certified to SAE Standard J2788 Fill out and return the Warranty Card within 90 days to activate warranty and free lifetime...

Страница 3: ...2 NOTES...

Страница 4: ...Enable A C Capacity Database Default Values 12 Fill Cylinder Target Amount Minimum Vacuum Leak Level Vacuum Leak Time Hose Overcharge Amount Maintenance Options 12 Calibration Check Perform Calibratio...

Страница 5: ...entry of data such as charge amount and given options such as vacuum leak test Once the necessary data has been entered the RHS980 will automatically perform the complete A C service and alert the tec...

Страница 6: ...RHS980 to moisture or operate in wet areas 9 Use the RHS980 in locations with ventilation that provides at least four air changes per hour 9 Service hoses must be constructed of the proper materials a...

Страница 7: ...tive procedure The alpha numeric keypad is used to enter data when prompted on the LCD screen Note The key also has U M printed on it Pressing this key will toggle the units of measure displayed on th...

Страница 8: ...tion three wire grounded 14 AWG or larger extension cord of the shortest possible length R T I T E C H N O L O G I E S R H S 9 8 0 S E L E C T L A N G U A G E E N G L I S H E S P A O L F R A N A I S D...

Страница 9: ...cycle and charge R134a Take extreme precaution to ensure that other refrigerants are not recovered into the RHS980 A refrigerant identifier is recommended for evaluating refrigerant in the A C system...

Страница 10: ...ress YES key if a vacuum leak test is required Otherwise press NO key Press YES key if oil is to be injected into the A C system Fill the oil bottle on the side of the RHS980 with new oil Otherwise pr...

Страница 11: ...o that oil can be injected if oil injection was selected previously Check the oil drain bottle to determine how much oil was removed from the A C system Open valve on new oil bottle until desired amou...

Страница 12: ...eens DEFAULT VALUES MAINTENANCE OPTIONS and TOTAL CAPACITIES These four setup procedures are described below Press START key The first option is to select the language which be used to display screens...

Страница 13: ...of time During this time the vacuum level will be monitored If the vacuum level decreases it s an indication that the A C system has a leak This screen prompts for the level of vacuum to be drawn Ente...

Страница 14: ...the RHS980 to the vapor port of a refillable DOT cylinder Open the valve on the cylinder Press START key Refrigerant will be transferred from the RHS980 internal cylinder into the externally connecte...

Страница 15: ...cate the need to go to recycle mode to eliminate the pressure This screen will display if pressure was not detected Replace the combo filter Note the serial number on the new combo filter label as it...

Страница 16: ...rt will display when the filter life is at 100 lbs The RHS980 will shut down when the filter life is at 150 lbs A new filter must be installed and a serial number entered to re start the RHS980 A spec...

Страница 17: ...4 New Refrigerant not included 5 Condenser Fan 6 Control Power Supply 7 Combo Filter 8 Charge Cylinder 9 Load Cell 10 Control Board 11 Oil Bottle Used 12 Oil Bottle New 13 Vacuum Pump 14 Compressor 1...

Страница 18: ...17...

Отзывы: