Notes to Observe in Using the REAC System

 

The REAC cable connected to the REAC port used by the REAC system to transmit sound can transmit multi-
channel audio signals by using network technology.

In very rare cases, noise may be generated when these systems are used in certain environments. If noise is 
present, check the following points.

As REAC cables use computer network technology, you should pay attention to the following points regarding 
wiring with network cables.

• Ensure that cables used for REAC connections conform to the Cat5e (Enhanced Category 5) standard.

• No single cable should be longer than 100 meters.

• Do not use cables with cut or torn coverings.

• Do not subject cables to undue stress.

• Do not wind or bend cables such that the radius of the turn is 25 mm or less, and do not double cables over.

• Do not bind cables tightly into bundles.

If you are making your own REAC cables, note the following precautions in addition to those above.

• Use plugs (RJ-45) conforming to high reliability standards.

• Do not separate the wires (twisted pairs) within the cables.

 

Cat5e Ethernet Cable Types

 

There are two different types of Cat5e Ethernet cables that you can use with the REAC System. Though the cables 
look the same on the outside, the RJ45 plugs are wired in different ways. With a:

 

crossover cable

 

—some of the wires inside the cable are “crossed over” at each RJ45 plug. As a result, the two 

RJ45 plugs on each end of a single cable are wired differently.

 

straight-through cable

 

—the wires inside the cable are connected to each RJ45 plug in the same arrangement 

(each plug is wired the same).

 

Use and Handling of REAC Systems

 

About REAC Cables

Notes to Observe When Producing REAC Cables

Understanding Cables and Connections

 

Either a crossover cable or a straight cable can be used for direct REAC connection of the S-OPT to 
another REAC device.

Содержание S-OPT

Страница 1: ...allations of the RSS Digital Snake System Two S OPT units can be connected using the proprietary POWER LINK cable ARC 15 sold separately so that redundant power can be supplied from one unit to the other If power to a single unit is interrupted due to some situation or is damaged both units will still continue to operate Main Specifications Copyright 2007 ROLAND CORPORATION All rights reserved No ...

Страница 2: ...has two blades with one wider than the other A grounding type plug has two blades and a third grounding prong The wide blade or the third prong are provided for your safety If the provided plug does not fit into your outlet consult an electrician for replacement of the obsolete outlet WARNING IMPORTANT As the colours of the wires in the mains lead of this apparatus may not correspond with the colo...

Страница 3: ...ower supply cord Also the supplied power cord must not be used with any other device 009 Do not excessively twist or bend the power cord nor place heavy objects on it Doing so can damage the cord producing severed elements and short circuits Damaged cords are fire and shock hazards 011 Do not allow any objects e g flammable material coins pins or liquids of any kind water soft drinks etc to penetr...

Страница 4: ... alcohol nail polish spray cans etc near the unit Swiftly wipe away any liquid that spills on the unit using a dry soft cloth 101a The unit should be located so that its location or position does not interfere with its proper venti lation 102b Always grasp only the plug on the power supply cord when plugging into or unplugging from an outlet or this unit 103a At regular intervals you should unplug...

Страница 5: ...nsation may form inside the unit Damage or malfunction may result if you attempt to use the unit in this condition Therefore before using the unit you must allow it to stand for several hours until the condensation has completely evaporated 360 Depending on the material and temperature of the surface on which you place the unit its rubber feet may discolor or mar the surface You can place a piece ...

Страница 6: ...REAC Port This port is used to connect REAC devices and REAC cables Connect to a REAC device using the REAC cable which comes with the S OPT a SC W100S REAC cable or a Cat5e Ethernet cable equipped with an RJ45 plug POWER Indicator EXT INT This indicator displays the power supply status When power is supplied from AC IN on the rear panel the INT LED lights blue In addition if another S OPT is conn...

Страница 7: ...its using the proprietary POWER LINK cable ARC 15 sold separately By sharing the power supply the power supply can be backed up Grounding Terminal If necessary use this terminal to connect the S OPT chassis to an external grounding source Rear Panel Never attempt to use the following sources for an external ground connection Water pipes may result in shock or electrocution Gas pipes may result in ...

Страница 8: ... such as a UPS Connect each AC IN of two S OPT units to a normal outlet Although both S OPT units will operate if one of the two S OPT units has power supplied to its AC IN it is recommended that power be connected and supplied to AC IN of both units to improve system reliability When there is an external backup power supply separate from the normal power supply such as UPS Connect AC IN of one S ...

Страница 9: ...e power supply using the POWER LINK cable ARC 15 sold separately prevent the cable from being unplugged by fixing it using the following procedure 1 Remove the clamp screws 2 specified in the diagram and remove the POWER LINK cable clamp 2 As shown in the figure clamp the POWER LINK cable using the cable clamp and secure with the screws 2 removed in Step 1 How to Use the Power Cord Clamps Using th...

Страница 10: ... the double sided adhesive tape on the rubber feet and attach the feet at the points indicated in the figure below Using the Unit While Mounted in a Rack Using the REAC Connector Cover Attaching the Rubber Feet When turning the S OPT upside down place stacks of newspapers or magazines to support the four corners or two sides so that stress is not placed on the S OPT itself Also handle the S OPT wi...

Страница 11: ...ind cables tightly into bundles If you are making your own REAC cables note the following precautions in addition to those above Use plugs RJ 45 conforming to high reliability standards Do not separate the wires twisted pairs within the cables Cat5e Ethernet Cable Types There are two different types of Cat5e Ethernet cables that you can use with the REAC System Though the cables look the same on t...

Страница 12: ...ilize rugged Neutrik EtherCon connectors When used with RJ45 plugs housed in EtherCon connectors this provides a robust latching connection similar to that provided by an XLR connector Neutrik offers EtherCon connectors for the fabrication of new cables models NE8MC 1 and NE8MC 1 B and EtherCon connectors that can be added to a pre made Ethernet cable models NE8MC and NE8MC B Cat5e Ethernet Cable ...

Страница 13: ...rrite core on the SC 100S or the Cat5e cable near the RJ45 plug that will be connected to the REAC port Use the following procedure to install a ferrite core on an Ethernet cable 1 Lift up the ferrite core s tabs and open the ferrite core fig 6 11 eps 2 Place the REAC cable SC W100S or Ethernet cable in the ferrite core so that the core abuts the base of the cable s connector fig 6 12 eps 3 Push t...

Страница 14: ...evice S OPT S OPT S 4000H 8x32 Slave REAC device 8 outputs from console 32 mic line inputs 32 mic line sources from stage 8 outputs from console Cat5e cables Cat5e cables Optical cables or optical cords in a redundant system for each Optical line in diagram ...

Страница 15: ...ple S 1608 16x8 Master REAC device S 0816 8x16 Slave REAC device 8 outputs from console 16 mic line sources from stage 8 outputs from console 16 mic line inputs S OPT S OPT Cat5e cable Cat5e cable Optical cable or optical cord ...

Страница 16: ...ion 10 W Dimensions 218 0 W x 239 9 D x 46 3 H mm 8 5 8 W x 9 1 2 D x 1 7 8 H inches Weight 1 3 kg 2 lbs 14 oz Operation Temperature 0 to 40 degrees centigrade 32 to 104 degrees Fahrenheit Accessories Power Cord x 1 REAC Cable 5m x 1 REAC Connector Cover x 1 Rubber Foot x 4 Screw Set x 1 Owner s Manual Options REAC Cable 100m SC W100S POWER LINK Cable ARC 15 AR LINK CABLE Rack Mount Adaptor BOSS R...

Страница 17: ...For EU Countries For China ...

Страница 18: ...2 4170 TAIWAN ROLAND TAIWAN ENTERPRISE CO LTD Room 5 9fl No 112 Chung Shan N Road Sec 2 Taipei TAIWAN R O C TEL 02 2561 3339 SINGAPORE MALAYSIA Roland Asia Pacific Sdn Bhd 45 1 Block C2 Jalan PJU 1 39 Dataran Prima 47301 Petaling Jaya Selangor MALAYSIA TEL 3 7805 3263 BRAZIL Roland Brasil Ltda Rua San Jose 780 Sala B Parque Industrial San Jose Cotia Sao Paulo SP BRAZIL TEL 011 4615 5666 Other CENT...

Отзывы: