163
Scene memory
Scene memory
Global Scope is a function that lets you limit the channels and
parameters that will be recalled; its settings apply to all scenes.
The GLOBAL SCOPE popup is used to make settings for the Global
Scope function.
fig.ScrRecallSafeGuide.eps
fig.ScrRecallSafeGuide2.eps
1.
Parameter recall scope buttons
(CH 1–24, CH 25–48, AUX/MAIN/MATRIX tab)
These buttons specify the scope of the parameters that will be
recalled for the channels selected by the channel recall scope
buttons.
Select the parameters that you want to include in the scope of
recall, and de-select the parameters that you don’t want to be
recalled.
The parameter recall scope buttons correspond to the following
parameters.
For CH1–CH48
For AUX/MAIN/MATRIX
2.
Channel recall scope buttons
These buttons specify the channels that will be included in the
recall scope.
Select the channels that you want to include in the scope of
recall, and de-select the channels that you don’t want to be
recalled.
3.
DCA/MUTE group recall scope buttons
These buttons specify the DCA/MUTE groups that will be
included in the recall scope.
Select the DCA/MUTE groups that you want to include in the
scope of recall, and de-select the DCA/MUTE groups that you
don’t want to be recalled.
4.
OTHER parameter recall scope buttons
Use these to specify other parameters that will be included in
the scope of recall.
Select the parameters that you want to include in the scope of
recall, and de-select the parameters that you don’t want to be
recalled.
In the GLOBAL SCOPE popup, the function buttons perform the
following operations.
The Global Scope function
GLOBAL SCOPE popup
Item
Explanation
Preamp
Preamp gain, pad, and +48V phantom power
Phase
Phase
ATT
Attenuator
Filter
Filter
Gate
Gate/Expander
Comp
Compressor
EQ
Four-band EQ
Sends
AUX sends
Direct
Direct out point
Fader
Faders
Pan
Pan
1
2
3
4
Item
Setting
ATT
Attenuator
EQ
Four-band EQ
Sends
AUX/MAIN sends
Fader
Faders
Balance
Balance
Limiter
Limiter
Button
Function
[F1 (CH 1–24)]
Displays CH1–CH24 as the channel recall
scope buttons.
[F2 (CH 25–48)]
Displays CH25–CH48 as the channel recall
scope buttons.
[F3 (AUX/MAIN/
MATRIX)]
Displays AUX1–AUX16, MATRIX1–
MATRIX8 and MAIN L/R as the channel
recall scope buttons.
[F4 (OTHER)]
Displays the DCA/MUTE group recall
scope buttons and the OTHER parameter
recall scope buttons.
[F8 (CLOSE)]
Closes the popup.
M-400_v15_e.book 163 ページ 2008年6月20日 金曜日 午後4時5分
Содержание M-400
Страница 247: ...MEMO M 400_v15_e book 247 ページ 2008年6月20日 金曜日 午後4時5分 ...
Страница 248: ...MEMO M 400_v15_e book 248 ページ 2008年6月20日 金曜日 午後4時5分 ...
Страница 249: ...MEMO M 400_v15_e book 249 ページ 2008年6月20日 金曜日 午後4時5分 ...
Страница 250: ...For EU Countries For China M 400_v15_e book 250 ページ 2008年6月20日 金曜日 午後4時5分 ...