![RSS AR-200S Скачать руководство пользователя страница 23](http://html1.mh-extra.com/html/rss/ar-200s/ar-200s_owners-manual_1496805023.webp)
23
Control I/O Connector Specifications
fig.ControlB
• Control Input and DC Input Terminal (CONTROL A) “1, 2” are
connected in parallel with Control I/O Connector (CONTROL B) “1, 2.”
• When using Program Playback on a PC card created by the AR-3000/
3000R, use connectors 1 (INC), 3 (DEC), 5 (EXCHANGE), 9 (START), and
10 (STOP).
*
Do not make any connection to NC pins, since this will cause faulty operation.
• Power can be supplied to the AR-200S from an external power supply
unit (DC power supply) as well as from the AC adaptor.
• To supply power from an external power supply unit (DC power), use
the Control Input and DC Input Terminal (CONTROL A) or the Control
I/O Connector (CONTROL B) DC IN and GND pins.
Power Supply Specifications
DC +9–24 V, 1200 mA
*
The DC OUT pin of the Control I/O Connector (CONTROL B) can be used as
power supply for a sensor, etc.
• Never short a power supply pin (21, 24, 25) to the GND pin, since this
will damage the unit.
• When using the DC OUT, be careful not to exceed the maximum rating
(100 mA).
• For reasons of safety, do not connect the DC IN + pin of the Control Input
and DC Input Terminal (CONTROL A) to metal parts such as the chassis
or the Control I/O Connector (CONTROL B).
• Do not supply electrical power simultaneously to multiple connectors or
terminals; doing so may result in damage to the unit.
Port No.
Signal Name
Remark
1
1/INC
Control Input
2
2
3
3/DEC
4
4
5
5/EXCHANGE
6
6
7
7
8
8
9
9/START
10
STOP
11
COM (GND)
12
COM (GND)
13
BUSY OUT
Control Output
14
NC
15
CONT OUT
Control Output
16
GND
17
BUSY OUT
Control Output
18
CONT OUT
19
NC
20
NC
21
DC OUT
+5V, Max: 100 mA
22
GND
23
GND
24
DC IN
+9–24V, 1200mA
25
DC IN
13
1
25
14
DC Power Supply
AR-200S_e.book 23 ページ 2006年3月31日 金曜日 午前10時9分