Sanitisation Guide 

NOTE:  Before  beginning  the sanitation  process please ensure  that  water is  turned off  at  the rnains and  refer  to the MSDS document 
for  further  information.  Use bioguard hand gel and ensure  gloves are  worn. 

Briefly  press cold/ambient 
dispense button  to release 
internal  water pressure  frorn 

the machine. 

Turn  on  incoming  water,  allow 
service  cartridge/doser  to fill. 

When  the  external  cleaning 
(rninirnurn 5  minutes) is 
completed,  flush  the  machine 
using  the  cold  button  with 
clean  water  until the dispense 
water  runs clear.  Repeat 
briefly  with  the  ambient 
button  (and sparkling button  if 
present). 

Rernove the  existing filter. 

Dispense  water  using the cold 

button  until the  water  appears 
pink.  Briefly  press the ambient 
button too.  Repeat  with 
sparkling button  if  present. 

Turn  off  water  and  rernove  the 
service filter.  Retain  service 
filter  for  reuse. 

Borg & Overstrom 

Install & Operation Manual 

Add  25  rnl  of  Bioguard 

Internal  Sanitisation  fluid to a 

clean  and  ernpty  service  filter 
cartridge. 

Leave the solution inside 

machine  for  sanitisation 

to take  effect  (rninirnurn 5 
minutes)  while thoroughly 
cleaning  the  machine 
externally,  pay  particular 
attention  to the  dispense 
faucet  and button controls. 

Fit new filter.  Turn  on  incoming 
water  supply. 

l l 

Connect  to machine. 

Rernernber  to include  the drip 
tray.  Ernpty  the Waste Overflow 
��rn a�fl�h�m�h��a 

srnall amount  of  sanitisation  fluid 
if  needed. 

Pre-flush the  new  filter  to  waste 
using  the ambient  button  (and 
sparkling button  if present) 

until the  water  appears 

clear  and is free  of  air.  Flush 
through  a  small  amount of 

water  to check all functions. 

GB 

Содержание Bag & Overstrom B5

Страница 1: ...Bag Overstrom B5 Cleaning Guide Contact us www refreshmentsystems co uk For Service service refreshmentsystems co uk 01274 750 008 For Ingredients ingredients refreshmentsystems co uk 01226 720 482 ...

Страница 2: ...Thiscleaningguideis foradviceonly Please referto theoperativemanualfor complete safetyinformationand instructionwhenconsidering any maintenanceonthe machine ...

Страница 3: ...ne is completely disconnected from electricity before carrying out any maintenance work Turn off the water supply To drain the Direct Chill tank remove the cap on the back of the machine We recommend it is refitted immediately upon draining being completed Install Operation Manual lO GB ...

Страница 4: ...nk Briefly press the ambient button too Repeat with sparkling button if present Turn off water and rernove the service filter Retain service filter for reuse Borg Overstrom Install Operation Manual Add 25 rnl of Bioguard Internal Sanitisation fluid to a clean and ernpty service filter cartridge Leave the solution inside machine for sanitisation to take effect rninirnurn 5 minutes while thoroughly ...

Страница 5: ...hing at the base of the tap To reset Unplug the machine and remove the protective cover Locate the Leak Detector valve Install Operation Manual Locate the source of leakage and rectify Reset the red lever push it in 12 Locate the detection probe which can be found in the bottom at the rear of the machine Dry the probes and internal area with a dry cloth Reconnect the power to machine and test oper...

Страница 6: ... empty of sparking water when only CO2 is being released Borg Overstrom Install Operation Manual 13 Qhct Qcdd Qf it ng Q porlding i Press and hold the Sparkling water dispense button until all water is expelled Ensure to release the Sparkling water button and take care to avoid releasing excess amounts of CO2 gas GB ...

Отзывы: