Enter the four digit user code, the buzzer will emit a steady
sound and the exit time start.  Press the Ô*Õ key followed by
the Ô9Õ key, then press the Ô3Õ key.  The log routine will start
viewing ÔDAYÕ 1 ÔSETÕ.

Key

View

1

Log 1

2

Log 2

3

Log 3

4

Log 4

5

Log 5

6

Log 6

7

Log 7

8

Log 8

9

Log 9

0

The last alarm

Press the Ô*Õ key to finish.

4.3 Walk test

You should test your system at regular intervals, to aid this
a walk test mode is provided.  You are allowed to test all
ALARM devices.  DO NOT TEST ANY PERSONAL
ATTACK BUTTONS.

Enter the four digit user code, the buzzer will emit a steady
sound and the exit time start.  Press the Ô*Õ key followed by
the Ô9Õ key, then press the Ô4Õ key.  The buzzer will emit a
low level steady tone.

As you test each device the internal sounder will give a loud
pulsing tone to indicate the correct operation of that device.
The zone number LED will light.  When the device test is
over the sounder will stop and the zone LED will go out.
The buzzer will emit a low level steady tone as before.

Report any faults to your alarm company.

Press the Ô*Õ key to finish.

Technical specification

Power supply

Mains supply voltage

240V~ Nom

PSU input voltage

13.7V~ Nom

PSU output voltage

12V Nom

Maximum output current

1A (total)

Aux. current

500mA max

Battery fuse

1A (20mm)

Panel quiescent

40mA

Keypads

Supply voltage

12V

Quiescent current

20mA

Active

45mA

Maximum cable run 100 metres

General

Operating temperature

10 to 50¡ centigrade

Humidity

Up to 80% non condensing

Dimensions

263mm (W)
223mm (H)
82mm (D)

Control panel weight

2.7kg excluding batt.

Standby battery

2.6AH 12V rechargeable
6AH max.

RS Components

Issued November 1994

9954