Enter the four digit user code, the buzzer will emit a steady
sound and the exit time start. Press the Ô*Õ key followed by
the Ô9Õ key, then press the Ô3Õ key. The log routine will start
viewing ÔDAYÕ 1 ÔSETÕ.
Key
View
1
Log 1
2
Log 2
3
Log 3
4
Log 4
5
Log 5
6
Log 6
7
Log 7
8
Log 8
9
Log 9
0
The last alarm
Press the Ô*Õ key to finish.
4.3 Walk test
You should test your system at regular intervals, to aid this
a walk test mode is provided. You are allowed to test all
ALARM devices. DO NOT TEST ANY PERSONAL
ATTACK BUTTONS.
Enter the four digit user code, the buzzer will emit a steady
sound and the exit time start. Press the Ô*Õ key followed by
the Ô9Õ key, then press the Ô4Õ key. The buzzer will emit a
low level steady tone.
As you test each device the internal sounder will give a loud
pulsing tone to indicate the correct operation of that device.
The zone number LED will light. When the device test is
over the sounder will stop and the zone LED will go out.
The buzzer will emit a low level steady tone as before.
Report any faults to your alarm company.
Press the Ô*Õ key to finish.
Technical specification
Power supply
Mains supply voltage
240V~ Nom
PSU input voltage
13.7V~ Nom
PSU output voltage
12V Nom
Maximum output current
1A (total)
Aux. current
500mA max
Battery fuse
1A (20mm)
Panel quiescent
40mA
Keypads
Supply voltage
12V
Quiescent current
20mA
Active
45mA
Maximum cable run 100 metres
General
Operating temperature
10 to 50¡ centigrade
Humidity
Up to 80% non condensing
Dimensions
263mm (W)
223mm (H)
82mm (D)
Control panel weight
2.7kg excluding batt.
Standby battery
2.6AH 12V rechargeable
6AH max.
RS Components
Issued November 1994
9954