  FACTORY

Visual work at production line

300 ~ 750

28 ~ 70

Inspection work

750 ~ 1,500

70 ~ 140

Electronic parts assembly line

1500 ~ 3,000 140 ~ 279

Packing work, Entrance passages

150 ~ 300

14 ~ 28

   HOTEL

Public room, Cloakroom

100 ~ 200

9 ~ 18

Reception

200 ~ 500

18 ~ 47

Cashier

750 ~ 1000

70 ~ 93

 

STORE

Indoors stairs & corridor

150 ~ 200

14 ~ 18

Shop window, Packing table

750 ~ 1,500

70~140

Forefront of shop window

1500 ~ 3,000

140 ~279

HOSPITAL

Sickroom, Warehouse

100 ~ 200

9 ~ 18

Medical examination room

300 ~ 750

28 ~ 70

Operating room
Emergency treatment area

750 ~ 1,500

70 ~ 140

SCHOOL

Auditorium, Indoor gymnasium

100 ~ 300

9 ~ 28

Class room

200 ~ 750

18 ~ 70

Laboratory, Library, or Drafting
room

500 ~ 1,500

47 ~ 140

Содержание RS-01

Страница 1: ...RS Light Meter RS 01 INSTRUCTION MANUAL D H...

Страница 2: ...NTRODUCTION 1 2 FEATURES 1 3 SPECIFICATIONS 2 4 NAME OF PARTS AND POSITIONS 3 5 OPERATING INSTRUCTIONS 4 6 BATTERY CHECK REPLACEMENT 9 7 SPECTRAL SENSITIVITY CHARACTERISTICS 10 8 MAINTENANCE 11 9 RECO...

Страница 3: ...asy to operate due to its construction The light sensitive components used in the meter are a very stable long life silicon photodiode and spectral response filter U S Pat No 446 135 2 2 F FE EA AT TU...

Страница 4: ...ed to standard incandescent lamp at a colour temperature of 2856 K Temperature characteristics 0 1 Sampling rate 5 times sec Photo detector Silicon photo diode and spectral response filter Manual data...

Страница 5: ...00 annunciators for measured values unit functions and decimal points etc 2 Power button The power button turns the instrument ON or OFF 3 AVG button Activates the point average mode 4 H Data hold but...

Страница 6: ...o Detector 5 5 O OP PE ER RA AT TI IN NG G I IN NS ST TR RU UC CT TI IO ON NS S 5 1 Illuminance Measurement 1 Press the power button to turn the meter on 2 Press lux fc button to select the desired un...

Страница 7: ...rage mode The annunciator AVG is displayed The maximum number of point measurements is 99 5 Each subsequent press of the MEM button stores one measured point value to memory The annunciator AVG NO XX...

Страница 8: ...vious point measured data as required h Press the AVG button to exit this mode 5 3 Luminous intensity measurement Luminous intensity is a light source property Defined as the quantity of luminous flux...

Страница 9: ...an be set between 0 01 to 30 47m or 0 01 to 99 99ft Luminous intensity measurement should only be made in a dark room or an equivalent environment where any light other than that from the source being...

Страница 10: ...l data memory Each press of the MEM button will store one set of readings to memory The LCD will briefly show the M mark and the memory address number The total number of memory locations available is...

Страница 11: ...ble auto power off function for continuous operation c Press button to turn the meter off d Press and hold down the HOLD button then press the button to turn the meter on The auto power off function w...

Страница 12: ...strument operates correctly 7 7 S SP PE EC CT TR RA AL L S SE EN NS SI IT TI IV VI IT TY Y C CH HA AR RA AC CT TE ER RI IS ST TI IC CS S The detector used in this instrument together with the incorpor...

Страница 13: ...operational conditions but generally the sensitivity decreases in direct proportion to the product of luminous intensity and the operational time The calibration accuracy may be enhanced by refitting...

Страница 14: ...n 200 500 18 47 Cashier 750 1000 70 93 STORE Indoors stairs corridor 150 200 14 18 Shop window Packing table 750 1 500 70 140 Forefront of shop window 1500 3 000 140 279 HOSPITAL Sickroom Warehouse 10...

Отзывы: