RS PRO RSSA3000X Скачать руководство пользователя страница 11

 

11 

 

 

 

Details of the Various Functions: 

 

 

Frequency: 

Sets the Center Freq\Start Freq\Stop Freq\Freq Step  

 

Span: 

Sets the Span\Full Span\Zero Span\Zoom In\Zoom Out\Last Span  

 

Amplitude: 

Used to Set the REF Level\Attenuator\Preamp\Amplitude 

 

Auto Tune: 

Automatically sets the optimal parameters according to the characteristics of the signal 

 

BW: 

Used to adjust the RBW,VBW,VBW/RBW Rate, Average Type (Logpower\Power\Voltage) 

 

Trace: 

Selects Trace\Trace setup\Trace math 

 

Sweep: 

Selects the Sweep time\Sweep Rule\Sweep Mode 

 

Detect: 

Selects the Detector type 

 

Trigger: 

Used in Selecting the Free Trigger\Video Trigger\External Trigger 

 

Limit: 

Sets the Pass\Fail Limit 

 

TG: 

Sets the TG Level\TG Level offset\Normalize  

 

Demod: 

Used to set the Parameters of the AM and FM  

 

Marker: 

Used to Select the Mark Trace and Marker math  

 

Содержание RSSA3000X

Страница 1: ...Quick Guide RSSA3000X Spectrum Analyzer...

Страница 2: ...2...

Страница 3: ...an reach the product or else the operator might be exposed to danger of electrical shock Electrostatic Prevention Operate the instrument in an electrostatic discharge protective area environment to av...

Страница 4: ...ct injuries or hazards that may happen WARNING indicates potential injuries or hazards that may happen CAUTION Indicates potential damages to the instrument or other property that may happen Symbols o...

Страница 5: ...according to its operating conditions 1 Disconnect the instrument from all power sources and then clean it with a soft cloth 2 Clean the loose dust on the outside of the instrument with a soft cloth...

Страница 6: ...nstrument has passed both electrical and mechanical tests 2 Inspect the instrument If the instrument is found to be damaged defective or fails in electrical or mechanical tests please contact your sal...

Страница 7: ...7 Appearance and Dimension Figure 1 Front View Figure 2 Top View...

Страница 8: ...ing Legs Adjust the supporting legs properly to use them as stands to tilt the Spectrum Analyzer upwards for stable placement as well as easier operation and observation of the instrument Before adjus...

Страница 9: ...to AC Power Supply The Spectrum Analyzer accept 100 240V 50 60 440Hz AC power supply Please use the power cord provided as accessories to connect the instrument to the power source as shown in the fig...

Страница 10: ...interface clear display with plenty of RF measurement functions The product can be used for research and development education production maintenance and other relevant applications The Front Panel 1...

Страница 11: ...he characteristics of the signal BW Used to adjust the RBW VBW VBW RBW Rate Average Type Logpower Power Voltage Trace Selects Trace Trace setup Trace math Sweep Selects the Sweep time Sweep Rule Sweep...

Страница 12: ...rameters Details of Channel Power ACPR Occupied BW T Power System Selects the Language Power on Preset Interface Calibration system information Data Time Self Test Mode Selects the Spec Analyzer EMI R...

Страница 13: ...13 The Rear Panel 1 1 Handle 2 USB Device 3 LANInterface 4 10MHz REFInput 5 10MHz REF Output 6 TriggerIn 7 SafetyLockHole 8 AC PowerSocket...

Страница 14: ...t the input signal to the RF input port does not contain more than 50 Volts DC The AC radio frequency input signal component should not exceed a maximum continuous power level of 30dBm 2 TG OUTPUT WAR...

Страница 15: ...15 1 3 4 Parameters setting area 2 Menu setting area 5 Active parameter 6 Display area 1 5 2 6 4 3 User Graphical Interface...

Страница 16: ...numbers through System Information For more information of this product please refer to the following manuals provided in the CD in the accessories Spectrum Analyzer User Manual provides detailed int...

Отзывы: