background image

 

TABLE OF CONTENTS 

TITLE                                                              PAGE 

I. 

WARNING ................................................................ 1 

II.  FEATURES............................................................... 2 

III.  INSTRUMENT LAYOUT........................................... 3 

IV.  SPECIFICATIONS .................................................... 4 

4-1 Voltage Measurement............................................ 6 

4-2 Manual and Autotest.............................................. 6 

4-3 Automatic Overheat Cut-Out ................................. 6 

V.  OPERATING INSTRUCTIONS................................. 7 

5-1 Correct Wiring........................................................ 7 

5-2 Measurement of the Loop Impedance .................. 7 

5-3 External Earth Probe ............................................. 8 

5-4 Measurement of Prospective Short Circuit Current..... 9 

 
 
 

Содержание IPT 1800

Страница 1: ...Instruction Manual IPT 1800 Digital LOOP PSC Tester FR EN IT DE ES P N P E...

Страница 2: ...3 IV SPECIFICATIONS 4 4 1 Voltage Measurement 6 4 2 Manual and Autotest 6 4 3 Automatic Overheat Cut Out 6 V OPERATING INSTRUCTIONS 7 5 1 Correct Wiring 7 5 2 Measurement of the Loop Impedance 7 5 3 E...

Страница 3: ...e to phase damage will result When conducting a test particularly on earth spikes do not touch any exposed metal work This is because the earth has a current flowing through it for the duration of the...

Страница 4: ...easures low loop impedance resolution of 0 01 Ohm High impedance ranges permit direct measurements of ground spikes Automatic lock out if test resistor overheats Safe voltage measurement function Audi...

Страница 5: ...EN 3 III INSTRUMENT LAYOUT P N P E AC CORD FI K EUR EATERNAL EARTH PROBE LCD DISPLAY...

Страница 6: ...ction 240V 13A 6kA HRC ceramic fuses General Dimensions 180 L x 130 W x 70 H mm Weight Approx 800g include battery Test Current 25A approx 20Ohm Display Large style 3 1 2 digit custom LCD AC Test Peri...

Страница 7: ...tegory 300V CAT single phase 230V Pollution Degree 2 This manual and product may use the following symbols adopted from International Safety Standards Equipment protected throughout by DOUBLE INSULATI...

Страница 8: ...ual and Autotest Manual Press and release the Test Button The result will be displayed for 3s and then the display will revert to zero 4 3 Automatic Overheat Cut Out To test in accordance with the IEE...

Страница 9: ...ON there is reversed phase and neon is ON there is reversed phase and neutral wiring 5 2 Measurement of the Loop Impedance Set the instrument to the 200 or 2000 range If the instrument is set to the 2...

Страница 10: ...robe The phase earth loop impedance of exposed metal of bonding portable appliances or metal conduit etc can be tested using the external earth probe provided Connect the unit to the socket as normal...

Страница 11: ...LCD with the appropriate units This will remain for 3s and then revert to zero An audible beep will sound on completion of the test For best results always test on the lowest possible range Note For l...

Страница 12: ......

Отзывы: