IDM 98IV

 & 

99IV / EN

 

16  

Specifications 

 

General Specifications 

 

Maximum voltage applied to any terminal :  

1000 V

ac

 rms or 1000 V

dc

. rms 

Display : 

6000 counts.  

Polarity Indication :  

Automatic, positive implied, negative indicated.

 

Overrange Indication : 

OL

 

Batteries Life : 

200hours ALKALINE Battery (No Backlight) 

Low Batteries Indication :  

Voltage drops below operating voltage,    will flash. 

Power Requirement : 

1xPP3 9V battery 

Auto Power Off : 

20 minutes. 

Operating Temperature :

  -10 ~10°C

 

                                                

10°C ~ 30°C (

80% RH),  

                                                 

30°C ~ 40°C (

75% RH), 

                                                 

40°C ~ 50°C (

45%RH)

 

Storage Temperature :  

-20°C  to 60°C , 0 to 80% R.H. (batteries not fitted) 

Temperature Coefficient :  

0.15 x (Spec.Accy) / °C, < 18°C  or > 28°C . 

Measure : 

Samples 3 times per second . 

Altitude : 

6561.7 ft (2000m) 

Safety : 

Complies with EN61010-1, UL61010-1,IEC 61010-1,  

                

CAT.IV. 600V, CAT.

. 1000V

 

Measurement 

Category 

Application 

Measurements on circuits not directly connected 

to mains. Examples include: Measurements on 

battery powered equipment and specially protected 

(internal) mains-derived circuits. 

II 

Measurements on circuits directly connected to the 

low voltage installation. Examples include:  

Household appliances, portable tools and similar 

equipment. 

III 

Measurements performed in the building  

installation. Examples include measurements on 

distribution boards, junction boxes, socket-outlets 

and wiring and cables in the fixed installation. 

IV 

Measurements performed at the source of the low-

voltage installation. Examples include measure-

ments on primary overcurrent protection devices 

and electricity Instruments

 

Содержание 873-2367

Страница 1: ...measurements Verify the Meter s operation by measuring a known voltage If in doubt have the Meter serviced Do not apply more than the rated voltage as marked on Meter between terminals or between any...

Страница 2: ...ter in mA A function to measure the voltage of a power supply circuit in equipment that could result in damage the meter and the equipment under test Symbols as marked on the Meter and Instruction man...

Страница 3: ...isplay 6000 counts 2 Push buttons 3 Rotary switch for turn the Power On Off and select the function 4 Input Terminal for A 5 Input Terminal for V functions 6 Common Input Terminal 7 Input Terminal for...

Страница 4: ...function AC DC function Frequency Counter on AC mode Capacitance Measurement Temperature for 99IV only Low battery indicator with segments Auto Power Off 20 minutes Shock proof from 4 feet drops CAT...

Страница 5: ...easurements Caution When connecting the test leads to the DUT Device Under Test connect the common test leads before connecting the live test leads when removing the test leads remove the live test le...

Страница 6: ...nd press the Function button to select the measuring function See Using the Function Button Measuring AC DC Current Frequency Disconnect AC Disconnect Rotate the switch and press the Function button t...

Страница 7: ...e Resistance Capacitance Rotate the switch and press the Function button to select the measuring function See Using the Function Button Measuring Continuity Diode Rotate the switch and press the Funct...

Страница 8: ...IDM 98IV 99IV EN 8 Measuring Temperature C F for 99IV only Rotate the switch and press the Function button to select the measuring function C F See Using the Function Button...

Страница 9: ...IV EN 9 Using The Function Buttons Function Button Switch Position Function Press AC Press button 2sec to Auto Range Mode Press the Function button to change the function on the same switch position R...

Страница 10: ...r 99IV only Min Reading Max Reading Press 2 sec Present Reading Press button over 2 sec then exit this function In the Peak HOLD function the meter records the peak min value and the peak max value wh...

Страница 11: ...arger than the display reading by 50 counts However it can not detect across the AC and DC Voltage Current VoltSeek Press the VoltSeek button to activate the VoltSeek function Caution The number of da...

Страница 12: ...o turn the backlight on off Auto Power Off 2 1 Reactivate the meter by rotating the switch or by pressing any button Auto Power Off Disable After idle 20 min Rotate the switch to the OFF position Pres...

Страница 13: ...ate the switch to the OFF position Press and hold down the SmartHOLD button and turn the meter on Default Temperature Units for 99IV only 2 1 2 1 2 1 Rotate the switch to the OFF position Press and ho...

Страница 14: ...nserting the batteries 4 Do not short circuit used batteries disassemble them or throw them in a fire Doing so may cause the batteries to explode 5 Dispose of the used batteries in accordance with loc...

Страница 15: ...eplace the battery as soon as the low battery indicator appears to avoid false reading Refer to the following figure to replace the batteries 9V Battery Battery Cover Screw Caution Remove test leads f...

Страница 16: ...3 times per second Altitude 6561 7 ft 2000m Safety Complies with EN61010 1 UL61010 1 IEC 61010 1 CAT IV 600V CAT 1000V Measurement Category Application I Measurements on circuits not directly connect...

Страница 17: ...80 RH AC Function ACV and ACA specifications are ac coupled true R M S The crest factor may be up to 3 0 at 4000 counts For non sinusoidal waveforms Additional Accuracy by Crest Factor C F Add 3 0 for...

Страница 18: ...0 01mA 1 5 3d 1 2 3d 600 0mAAC 0 1mA 1 5 3d 1 2 3d AC 600 0mV ranges are specified from 1 of range to 100 of range Input Impedance 10M less than 100pF Overload Protection AC DC 1000V Range Resolution...

Страница 19: ...s rest time 10A for max 30 seconds with at least 10 minutes rest time AC Frequency Response 45 1kHz Sine Wave Overload Protection AC DC 11A 7 Peak Hold For 99 only Specified accuracy 150 digits for 60...

Страница 20: ...1000V 12 Frequency Counter Range Resolution Accuracy 100 00 Hz 0 01 Hz 0 1 2d 1000 0 Hz 0 1 Hz 10 000 KHz 0 001 KHz 100 00 KHz 0 01 KHz Minimum Sensitivity 6V for ACV 1Hz 10kHz 12V for ACV 10kHz 50kHz...

Страница 21: ...lution For 98IV Accuracy For 99IV Accuracy 60 00mA 0 01mA 2 5 5d 2 5d 600 0mA 0 1mA Range Resolution For 98IV Accuracy For 99IV Accuracy 6 000A 0 001A 2 5 5d 2 5d 10 00A 0 01A Additional specification...

Страница 22: ...repair alteration contamination or abnormal conditions of operation or handling Any implied warranties arising out of the sale of this product including but not limited to implied warranties of mercha...

Страница 23: ...Road Shanghai 200001 China www rs components com Europe RS Components Ltd PO Box 99 Corby Northants NN17 9RS United Kingdom www rs components com Japan RS Components Ltd West Tower 12th Floor Yokoham...

Страница 24: ...EN Instruction Manual IDM 98IV IDM 99IV Digital Multimeter...

Отзывы: