RS PRO 1804786 Скачать руководство пользователя страница 1

 

 

 

User Manual 

 

 

 

rspro.com

 

 

 

RSMSO-2000E series 

Stock number: 1804786 

RSMSO-2102E

     1804787 

RSMSO-2104E

 

1804788 

RSMSO-2202E 

1804789 

RSMSO-2204E

 

1804790 

RSMSO-2102EA 

1804791 

RSMSO-2104EA

 

1804792 

RSMSO-2202EA 

1804793 

RSMSO-2202EA

 

 

 EN

 

Содержание 1804786

Страница 1: ...l rspro com RSMSO 2000E series Stock number 1804786 RSMSO 2102E 1804787 RSMSO 2104E 1804788 RSMSO 2202E 1804789 RSMSO 2204E 1804790 RSMSO 2102EA 1804791 RSMSO 2104EA 1804792 RSMSO 2202EA 1804793 RSMSO...

Страница 2: ......

Страница 3: ...t 44 Cursor Measurement 58 Math Operation 65 ADVANCED CONFIGURATION 75 Acquisition 78 Segmented Memory Acquisition 83 Display 95 Horizontal View 100 Vertical View Channel 108 Bus Key Configuration 116...

Страница 4: ...RECALL 270 File Format Utility 271 Create Edit Labels 276 Save 279 Recall 286 Reference Waveforms 292 FILE UTILITIES 294 HARDCOPY KEY 300 REMOTE CONTROL CONFIG 304 Interface Configuration 305 MAINTENA...

Страница 5: ...Product name WARNING Warning Identifies conditions or practices that could result in injury or loss of life CAUTION Caution Identifies conditions or practices that could result in damage to the equip...

Страница 6: ...ot disassemble the RSMSO 2000E 2000EA unless you are qualified Note Measurement categories EN 61010 1 2010 specifies the measurement categories and their requirements as follows The RSMSO 2000E 2000EA...

Страница 7: ...tter solid liquid or gaseous ionized gases that may produce a reduction of dielectric strength or surface resistivity Pollution degree 1 No pollution or only dry non conductive pollution occurs The po...

Страница 8: ...instrument as unsorted municipal waste Please use a separate collection facility or contact the supplier from which this instrument was purchased Please make sure discarded electrical waste is properl...

Страница 9: ...the terminal which is marked with the letter N or coloured Blue or Black The wire which is coloured Brown must be connected to the terminal marked with the letter L or P or coloured Brown or Red If in...

Страница 10: ...ion also includes an introduction on how to use this manual effectively RSMSO 2000E 2000EA Series Overview 9 Integrated instruments and series lineup 9 Main Features 10 Accessories 11 Appearance 13 RS...

Страница 11: ...els Arbitrary Wave Generator 2 channels RSMSO 2000E RSMSO 2000EA The RSMSO 2000E series consists of 8 models divided into 2 channel and 4 channel versions Model name Frequency bandwidth Input channels...

Страница 12: ...tively capture only the important signal details Up to 29 000 successive waveform segments can be captured with a time tag resolution of 4ns Waveform Search Allows the scope to search for a number of...

Страница 13: ...ion dependent Power cord GTP 100B 4 for RSMSO 2102E 2102EA RSMSO 2104E 2104EA Passive probe 100 MHz GTP 200B 4 for RSMSO 2202E 2202EA RSMSO 2204E 2204EA Passive probe 200 MHz GTL 16E 16 channel Logic...

Страница 14: ...12 rspro com Optional Accessories Part number Description Demo mode Demonstration mode that is used with the GDB 03 demo board GDB 03 Demo board Drivers others USB driver LabVIEW driver...

Страница 15: ...Option key Menu key Logic Analyzer Probe connector CH1 CH4 RSMSO 2000E 2 channel models Front Panel LCD Variable knob and Select key Autoset Run Stop Single and Default settings CH1 CH2 EXT TRIG Trigg...

Страница 16: ...m a menu use the side menu keys on the side of the panel See page 30 for details VARIABLE POSITION HORIZONTAL PUSH TO ZERO Measure Display Cursor Help Test Save Rec Select Search Set Clear Zo POSITION...

Страница 17: ...ifferent functions on the RSMSO 2000E 2000EA Measure Measure Configures and runs automatic measurements Cursor Cursor Configures and runs cursor measurements APP APP Configures and runs PR PRO applica...

Страница 18: ...nted Memory acquisition page 87 Single Single Sets the acquisition mode to single triggering mode Default Setup Default Resets the oscilloscope to the default settings Horizontal Controls The horizont...

Страница 19: ...and threshold Search Arrows Use the arrow keys to navigate the search events Set Clear Set Clear Use the Set Clear key to set or clear points of interest when using the search function Trigger Control...

Страница 20: ...E Sets the vertical scale of the channel TIME DIV External Trigger Input EXT TRIG Accepts external trigger signals page 143 Only on 2 channel models Input impedance 1M Voltage input 15V peak EXT trigg...

Страница 21: ...UT ground lead for common ground Probe Compensation Output 2V The probe compensation output is used for probe compensation It also has an adjustable output frequency By default this port outputs a 2Vp...

Страница 22: ...UCTOR MUST BE CONNECTED TO GROUND Ser No Label RSMSO 2000EA Rear Panel Calibration output Key lock Power input socket Fan Go No Go output LAN port USB Device port GEN 2 GEN 1 LINE VOLTAGE AC 100 240V...

Страница 23: ...scope to be mounted to a share disk Power Input Socket Power cord socket accepts AC mains 100 240V 50 60Hz For power up sequence see page 26 Security Slot Kensington security slot compatible Go No Go...

Страница 24: ...nd sample rate Digital channels Analog Waveforms Shows the analog input signal waveforms Channel 1 Yellow Channel 2 Blue Channel 3 Pink Channel 4 Green Bus decoding Shows serial bus data decoding The...

Страница 25: ...red to the internal memory page 100 Trigger Status Trig d Triggered PrTrig Pre trigger Trig Not triggered display not updated Stop Trigger stopped Also appears in Run Stop page 40 Roll Roll mode Auto...

Страница 26: ...24 rspro com Horizontal Status Horizontal scale horizontal position For trigger details see page 143 Channel Status Channel 1 DC coupling 2V Div For channel details see page 108...

Страница 27: ...25 Set Up Tilt Stand Tilt To tilt pull the legs forward as shown below Stand To stand the scope upright push the legs back under the casing as shown below...

Страница 28: ...nnect the power cord to the rear panel socket 2 Press the POWER key The display becomes active in 30 seconds ON OFF POWER Note The RSMSO 2000E 2000EA recovers the state right before the power is turne...

Страница 29: ...the latest firmware Page 325 3 Set the Date and Time Set the date and time Page 194 4 Reset System Reset the system by recalling the factory settings Press the Default key on the front panel For detai...

Страница 30: ...ER CH1 CH2 CH3 CH4 2V CAT I 1M W 16pF 300Vrms MAX x1 x10 X10 X1 CH1 2V 6 Capture Signal Autoset Press the Autoset key A square waveform appears on the center of the screen For Autoset details see page...

Страница 31: ...her operations Measurement page 36 Configuration page 75 Using the Logic Analyzer page 197 Using the Arbitrary Wave Generator RSMSO 2000EA only page 213 Applications page 246 Save Recall page 270 File...

Страница 32: ...u item For example in the example below Coupling is currently set to DC If a menu item can be toggled from one value or parameter to another the available options will be visible with the current opti...

Страница 33: ...ble parameter use the Variable knob to scroll through menu items or variables Use the Select key to confirm and exit The Select key is lit up when such selection can be made Select VARIABLE 4 Press th...

Страница 34: ...ss the desired menu key to select it The circular arrow will become highlighted 6 Use the Variable knob to edit the value Toggling a Menu Parameter 1 7 Press the bottom menu key to toggle the paramete...

Страница 35: ...u key to reduce the trigger menu VARIABLE POSITION HORIZONTAL POSITION POSITION POSITION POSITION VERTICAL MATH REF BUS SCALE TRIGGER LEVEL PUSH TO ZERO SCALE SCALE SCALE PUSH TO ZERO PUSH TO ZERO PUS...

Страница 36: ...ty Autose Run Sto Single Default Select Search Set Clear Zoom CH1 CH2 CH3 CH4 M R B Menu 50 Force Tr 1 Remove On Screen Messages 11 The Menu Off key can also be used to remove any on screen messages V...

Страница 37: ...lay changes to Help mode Help 2 Use the Variable knob to scroll up and down through the Help contents Press Select to view the help on the selected item Example Help on the Display key Home Key Press...

Страница 38: ...easurement 48 Remove Measurement 50 Gated mode 50 Display All mode 51 High Low Function 52 Statistics 54 Reference Levels 56 Cursor Measurement 58 Use Horizontal Cursors 58 Use Vertical Cursors 62 Mat...

Страница 39: ...213 Applications from page 246 Before operating the oscilloscope please see the Getting Started chapter page 8 Channel Activation Activate Channel To activate an input channel press a channel key Whe...

Страница 40: ...settings to position the input signal s to the best viewing condition The RSMSO 2000E 2000EA automatically configures the following parameters Horizontal scale Vertical scale Trigger source channel Th...

Страница 41: ...ttom menu 5 Press the Autoset key again to use Autoset in the new mode Autoset Fit Screen Mode AC Priority Limitation Autoset does not work in the following situations Input signal frequency is less t...

Страница 42: ...quisition freezes Stop Run Stop Run Stop To unfreeze press the Run Stop key again The Run Stop key turns green again Run Run Stop Run Stop Freeze Waveform by Single Trigger Mode Press the Single key t...

Страница 43: ...hen pressing Reset H Position to 0s from the bottom menu will also reset the horizontal position Acquire As the waveform moves the display bar on the top of the display indicates the portion of the wa...

Страница 44: ...r indicates how much of the waveform is displayed on the screen at any given time Changes to timebase will be reflected on the display bar Fast Medium Slow Stop mode In the Stop mode the waveform size...

Страница 45: ...he position to 0 As the waveform moves the vertical position of the cursor appears on the display POSITION PUSH TO ZERO Run Stop mode The waveform can be moved vertically in both Run and Stop mode Sel...

Страница 46: ...FPREShoot RPREShoot FOVShoot ROVShoot Cycle Area Area Cycle RMS RMS Cycle Mean Mean Low High Amplitude Min Max Pk Pk Frequency Dutycycle Width Width FallTime RiseTime Period Edges Edges Pulses Pulses...

Страница 47: ...is calculated for all data samples within the first cycle found in the gated region RMS The root mean square of all data samples specified by the Gating option Cycle RMS The root mean square value is...

Страница 48: ...to the high reference value FallTime The time required for the falling edge of the first pulse to fall from the high reference value to the low reference value Width Positive pulse width Width Negativ...

Страница 49: ...ce 1 first rising edge and Source 2 first falling edge FFR Time between Source 1 first falling edge and Source 2 first rising edge FFF Time between Source 1 first falling edge and Source 2 first falli...

Страница 50: ...f the screen from any channel source Add Measurement Item 1 Press the Measure key Measure 2 Press Add Measurement from the bottom menu 3 Choose either a V I Time or Delay measurement from the side men...

Страница 51: ...green CH4 Choose a Source The channel source for measurement items can be set either before or when selecting a measurement item 5 To set the source press either the Source1 or Source2 key from the s...

Страница 52: ...tem that you want to remove from the measurement list Remove All Items Press Remove All to remove all the measurement items Gated mode Some automatic measurements can be limited to a gated area betwee...

Страница 53: ...he cursor menu Page 58 Display All mode Display All mode shows and updates all items from Voltage and Time type measurements View Measurement Results 1 Press the Measure key Measure 2 Press Display Al...

Страница 54: ...he individual measurement mode page 48 instead Digital channels Only Frequency Period Width Width and Duty Cycle measurements are supported for the digital channels D0 D15 High Low Function Background...

Страница 55: ...is particularly useful for pulse type waveforms low high Min max Sets the high low values as the minimum or maximum measured values low high Set High Low 1 Press the Measure key Measure 2 Press High...

Страница 56: ...information is displayed with the Statistics function Value Currently measured value Mean The mean value is calculated from a number of automatic measurement results The number of samples used to dete...

Страница 57: ...of samples used to determine the standard deviation can be user defined Panel Operation 1 Press the Measure key Measure 2 Select at least one automatic measurement Page 48 3 Press Statistics from the...

Страница 58: ...levels for some measurements like the Rise Time measurement High Ref Sets the high reference level Mid Ref Sets the middle reference for the first and second waveforms Low Ref Sets the low reference l...

Страница 59: ...57 High Ref 0 0 100 Mid Ref 0 0 100 0 0 100 Low Ref 0 0 100 Default Settings 4 Press Set to Defaults to set the reference levels back to the default settings...

Страница 60: ...hey will be shown on the main display unless turned off Use Horizontal Cursors Panel Operation 1 Press the Cursor key once Cursor 2 Press H Cursor from the bottom menu if it is not already selected 3...

Страница 61: ...ft or right VARIABLE Note The selected cursor s will move along the active waveform To move along another waveform select its corresponding channel and press the cursor key again to re enter the curso...

Страница 62: ...use different units For FFT details see page 67 Cursor Hor position dB Voltage Cursor Hor Position dB Voltage Delta difference between cursors dV dt or d dt Example Horizontal cursors XY Mode XY mode...

Страница 63: ...61 Cursor Time rectangular polar co ordinates product ratio Cursor Time rectangular polar co ordinates product ratio Delta difference between cursors Example Horizontal cursors...

Страница 64: ...will toggle which vertical cursor is selected OR Select Range Upper cursor movable lower cursor position fixed Lower cursor movable upper cursor position fixed Upper and lower cursor movable together...

Страница 65: ...o set the 0 and 100 ratio references for the current cursor position press Set Cursor Positions As 100 Example Horizontal cursors Vertical cursors FFT FFT has different content For FFT details see pag...

Страница 66: ...s measure a number of X by Y measurements See page 79 Cursor Rectangular polar co ordinates product ratio Cursor Rectangular polar co ordinates product ratio Delta difference between cursors Example H...

Страница 67: ...ion Adds the amplitude of two signals Source CH1 4 Ref1 4 Subtraction Extracts the amplitude difference between two signals Source CH1 4 Ref1 4 Multiplication Multiplies the amplitude of two signals S...

Страница 68: ...ears on the display The vertical scale of the math waveform appears at the bottom of the screen From left Math function source1 operator source2 Unit div Example Math Source 2 Source 1 Position and Un...

Страница 69: ...V or A Turn Off Math To turn off the Math result from the display press the Math key again MATH M FFT Overview Window Functions Background The FFT function performs a Fast Fourier Transform on one of...

Страница 70: ...enon this mode is the same as having no window at all Blackman Frequency resolution Bad Amplitude resolution Very good Suitable for Amplitude measurement on periodic waveforms FFT Operation Panel Oper...

Страница 71: ...e to frequency and the vertical scale from voltage current to dB RMS Math Source Position and Scale To move the FFT waveform vertically press Vertical until the Div parameter is highlighted and then u...

Страница 72: ...math function allows complex math expressions to be created based on the input sources reference waveforms or even the automatic measurements available from the Measure menu see page 44 An overview of...

Страница 73: ...are supported Measurement Pk Pk Max Min Amp High Low Mean CycleMean RMS CycleRMS Area CycleArea ROVShoot FOVShoot Freq Period Rise Fall PosWidth NegWidth Dutycycle FRR FRF FFR FFF LRR LRF LFR LFF Phas...

Страница 74: ...hlight a source function variable operator figure or measurement in orange Press the Select key to make the selection If a particular parameter is grayed out it indicates that that particular paramete...

Страница 75: ...digit and use the variable knob to set the value of the selected digit 11 Press Exponent Use the Variable knob to set the exponent of the variable 12 Press Go Back to finish editing VAR1 or VAR2 Vert...

Страница 76: ...74 rspro com Clear Advanced Math To clear the advanced math result from the display press the Math key again MATH M...

Страница 77: ...ay 95 Display Waveform as Dots or Vectors 95 Set the Level of Persistence 95 Set the Intensity Level 96 Select Display Graticule 97 Freeze the Waveform Run Stop 98 Turn Off Menu 99 Horizontal View 100...

Страница 78: ...th the Serial or Parallel Bus 141 Trigger 143 Trigger Type Overview 143 Trigger types and sources 145 Trigger Parameter Overview 146 Setup Holdoff Level 153 Setup Trigger Mode 154 Using the Edge Trigg...

Страница 79: ...g Single Search Events 187 FFT Peak 188 System Settings and Miscellaneous Settings 192 Select Menu Language 192 View System Information 193 Erase Memory 193 Set Date and Time 194 Probe Compensation Fr...

Страница 80: ...de Every sample from each acquisition is used Peak detect Only the minimum and maximum value pairs for each acquisition interval bucket are used This mode is useful for catching abnormal glitches in t...

Страница 81: ...tect Average Average sample 2 4 8 16 32 64 128 256 Example Sample Peak Detect Average 256 times Show Waveform in XY Mode Background The XY mode maps the input of channel 1 to the input of channel 2 In...

Страница 82: ...ir is active CH1 CH2 or CH3 CH4 Press the Channel key if necessary A channel is active if the channel key is lit CH1 CH1 CH2 CH2 Panel Operation 3 Press the Acquire menu key Acquire 4 Press XY from th...

Страница 83: ...the XY mode Turn Off XY Mode To turn off XY mode choose OFF YT mode Cursors and XY Mode Cursors can be used with XY mode See the Cursor chapter for details Page 58 Set the Record Length Background Th...

Страница 84: ...eration 1 Press the Acquire key Acquire 2 Press the Record Length key on the bottom menu and choose the record length Record length 1000 10k 100k 1M 10M points Note The sampling rate may also be chang...

Страница 85: ...ulses normally the oscilloscope will acquire the signal until the acquisition memory of the scope is filled up and then it will re arm the trigger and then capture again This could result in a number...

Страница 86: ...o notice that the scope doesn t need to rearm the trigger between each segment this makes the segmented memory function especially useful for high speed signals The time between each segment is also r...

Страница 87: ...dicator Progress Indicator Indicates the number of segments that have to been captured relative to the set number of segments Run Stop Indicator Stop The segments have finished acquiring or have been...

Страница 88: ...umber of segments 1000 pt 1 29000 10k pt 1 2900 100k pt 1 290 1M pt 1 20 10M pt 1 2 Panel Operation 1 Press the Acquire key Acquire 2 Press Segments on the bottom menu 3 Press Select Segments and set...

Страница 89: ...the segments will automatically be run Each segment will be automatically captured 2 The scope will automatically start acquiring segments The progress of the segmented memory capture is shown in the...

Страница 90: ...r Segment Stop icon The scope is now ready to navigate or analyze the acquired segments Rerun Segmented Acquisition 6 To rerun the segments press the Segments Stop key to toggle the mode back to the S...

Страница 91: ...nd use the Variable knob to scroll to the segment of interest Alternatively the Set to Minimum and Set to Maximum keys can be used to jump to the first and last segment respectively 3 The position in...

Страница 92: ...urements configured in the Measurement menu see page 44 Please note that Digital channels measurements cannot be used in conjunction with the segmented memory Modes Segments Measure This function will...

Страница 93: ...l the currently selected automatic measurement results are listed A maximum of 8 automatic measurements can be used with this function Note To use automatic measurements with the segmented memory auto...

Страница 94: ...ss Plot Source to choose which automatic measurement to use for the statistics calculations The statistics for only one automatic measurement can be viewed at a time 6 For the measurement list press S...

Страница 95: ...stics Statistics of currently selected bin Cursor selected bin Bin count Measurement List Puts all the measurement results for a segment in a list Setup 9 Press Select and use the variable knob to scr...

Страница 96: ...from the bottom menu Note This key will only be available in the Stop mode 2 Press Segments Info 3 A table showing all general setting information for the segmented memory acquisitions is shown on th...

Страница 97: ...play 2 Press Dot Vector to toggle between Dot and Vector mode Range Dots Only the sampled dots are displayed Vectors Both the sampled dots and the connecting line are displayed Example Vectors Dots Se...

Страница 98: ...lear Persistence Set the Intensity Level Background The intensity level of a signal can also be set to mimic the intensity of an analog oscilloscope by setting the digital intensity level Panel Operat...

Страница 99: ...de menu and edit the intensity value Range 2 100 Backlight Auto Dim 6 To automatically dim the backlight after a set duration set Backlight Auto Dim to On and then set Time to the appropriate time Aft...

Страница 100: ...er frame Freeze the Waveform Run Stop For more details about Run Stop mode see page 40 Panel Operation 1 Press the Run Stop key The Run Stop key turns red and waveform acquisition is paused Run Stop R...

Страница 101: ...el Operation 1 Press the Menu Off key below the side menu keys to reduce a menu The menu key needs to be pressed each time to reduce one menu See page 30 for more information POSITION SCALE PUSH TO ZE...

Страница 102: ...r on the on the top of the display indicates the horizontal position of the waveform in memory Reset Horizontal Position 1 To reset the horizontal position press the Acquire key and then press Reset H...

Страница 103: ...v 100s div 1 2 5 increment The timebase indicator updates as the horizontal scale is adjusted Horizontal position Timebase Run Mode In Run mode the memory bar and waveform size keep their proportion W...

Страница 104: ...waveform at once Automatically selected when the timebase sampling rate is fast Timebase 50ms div Trigger all modes Roll Mode Updates and moves the waveform gradually from the right side of the displ...

Страница 105: ...ckground When in Zoom mode the screen is split into 2 sections The top of the display shows the full record length while the bottom of the screen shows the normal view Panel Operation 1 Press the Zoom...

Страница 106: ...nob The zoom time base Z at the bottom of the screen will change accordingly SCALE Move the Zoom Window Use the Horizontal Position knob to pan the zoom window horizontally To reset the zoom position...

Страница 107: ...he original view press the Zoom key again Zoom Play Pause Background The Play Pause key can be used to play through signals in the Zoom mode Note If the Segmented memory function is turned on pressing...

Страница 108: ...e Zoom position Zoom window Play Pause indicator Zoom To increase the zoom range use the horizontal Scale knob The zoom time base Z at the bottom of the screen will change accordingly SCALE Scroll Spe...

Страница 109: ...position and horizontal position press Reset Zoom H POS to 0s Pause Press the Play Pause key to pause or resume playing the waveform Reverse Direction Press the Play Pause key when at the end of the...

Страница 110: ...ZERO 2 As the waveform moves the vertical position of the cursor appears at the bottom half of the display View or Set the Vertical Position 3 Press a channel key The vertical position is shown in the...

Страница 111: ...e vertical scale setting can be changed Select Coupling Mode Panel Operation 1 Press a channel key CH1 2 Press Coupling repeatedly to toggle the coupling mode for the chosen channel Range DC coupling...

Страница 112: ...ackground The input impedance of the RSMSO 2000E 2000EA is fixed at 1M The impedance is displayed in the channel menu View Impedance 1 Press the Channel key CH1 2 The impedance is displayed in the bot...

Страница 113: ...lters available are dependent on the bandwidth of the oscilloscope model Also refer to the digital filter application page 258 Panel Operation 1 Press the Channel key CH1 2 Press Bandwidth from the bo...

Страница 114: ...2 Press Expand repeatedly to toggle between expand By Ground and Center Range By Ground By Center Example If the vertical scale is changed when the Expand function is set to ground the signal will ex...

Страница 115: ...ter Expand by Center Select Probe Type Background A signal probe can be set to voltage or current Panel Operation 1 Press the Channel key CH1 2 Press Probe from the bottom menu 3 Press the Voltage Cur...

Страница 116: ...ss the Channel key CH1 2 Press Probe from the bottom menu 3 Press Attenuation on the side menu and use the Variable knob to set the attenuation Alternatively press Set to 10X Range 1mX 1kX 1 2 5 step...

Страница 117: ...skew on the side menu and use the Variable knob to set the deskew time Alternatively press Set to 0s to reset the deskew time Range 50ns 50ns 10ps increments 4 Repeat the procedure for another channel...

Страница 118: ...it Stop bit Start Bit Start of Frame The Start bit is shown as an open bracket Serial bus data only Stop Bit End of Frame The Stop bit is shown as a closed bracket Serial bus data only Data Data packe...

Страница 119: ...If there is an error missing acknowledgement in decoding the data a red error indicator will be shown Bus Indicator The Bus indicator shows the bus position The active bus is shown with a solid color...

Страница 120: ...mmon UART serial communications The UART serial bus software is suitable for a number of RS 232 protocol variants Inputs Tx Rx Threshold Tx Rx Configuration Baud rate Parity Packets End of packets Inp...

Страница 121: ...nputs CAN Input Threshold CAN Input Configuration Signal Type Bit Rate Trigger On Start of Frame Type of Frame Identifier Data Id Data End of Frame Missing Ack Bit Stuffing Err LIN The LIN Local Inter...

Страница 122: ...ynchronous Receiver Transmitter UART or RS 232 driver receiver ICs commonly used for embedded applications typically use active high signaling with standard IC signal levels Operation 1 Connect each o...

Страница 123: ...ity Normal High 0 Inverted High 1 Depending on your choice at step 4 above Configuration The Configure key sets the baud rate number of data bits and parity 7 Press Configure from the bottom menu 8 Fr...

Страница 124: ...an be configured for 7 or 10 bit addressing with the option to ignore the R W bit as well as triggering on a data value or a specific address and direction read or write or both Panel operation 1 Conn...

Страница 125: ...puts from the bottom menu 6 From the side menu choose the SCLK input and the SDA Input SCLK CH1 CH4 or D0 D15 SDA CH1 CH4 or D0 D15 Depending on your choice at step 4 above Include R W in address To c...

Страница 126: ...vailable for 4 channel models Panel operation 1 Connect each of the bus signals SCLK SS MOSI MISO to the oscilloscope s 4 analog channels or to one of the digital channels Connect the ground potential...

Страница 127: ...ISO OFF CH1 CH4 or OFF D0 D15 Depending on your choice at step 4 above Configuration The Configure menu sets the data line logic level SCLK edge polarity word size and bit order 7 Press Configure from...

Страница 128: ...00EA only needs one wire CAN High or CAN Low for decoding Panel operation 1 Connect the bus signal CAN Input to one of the oscilloscope s analog or digital channels Connect the ground potential to one...

Страница 129: ..._L Tx Rx Depending on your choice at step 4 above Note The Sample Point soft key indicates the sampling position of each bit This parameter is fixed Bit Rate The Bit Rate menu sets the bit rate of the...

Страница 130: ...re using the analog channels or to the ground connector of the Digital card if you are the using digital channels LIN input GND G 1 X1 0 X1 Analog Digital 2 Press the Bus key BUS B 3 Press Bus from th...

Страница 131: ...position of each bit This parameter is fixed Configuration The Configure menu sets the bit rate the LIN standard and the parity options for the Id frame 7 Press Configure from the bottom menu 8 From...

Страница 132: ...be displayed as binary hexadecimal or ASCII An event table can also be created to aid in debugging Panel operation 1 Connect each of the parallel bus signals variable length can be configured to the o...

Страница 133: ...us To add a clock bit press Clock Edge and select type of clock edge Selecting Off will disable the clock bit 7 If you wish to define which channels are assigned to the bus press Select Signal from th...

Страница 134: ...threshold levels for the Serial or Parallel buses can be set to either a user defined threshold level or to pre set threshold Set the Threshold 1 Press Threshold from the bottom menu 2 Press Select fr...

Страница 135: ...cale Scale Range Scale Range 10V Div 290V 50mV Div 5 2V 5V Div 270V 20mV Div 580mV 2V Div 33V 10mV Div 540mV 1V Div 29V 5mV Div 520mV 500mV Div 27V 2mV Div 508mV 200mV Div 5 8V 1mV Div 504mV 100mV Div...

Страница 136: ...s Operation 1 Press Event Table from the bottom menu 2 Press Event Table from the side menu to turn the event table on or off Event On Off Use the Variable knob to scroll through the event table Data...

Страница 137: ...ime of trigger Tx Rx Errors Select cursor Example I2 C Event table Time of trigger Repeat Start Address Data at address Missing Ack Select cursor Example I2 C Data Detail Time of trigger Address Data...

Страница 138: ...t table Time of trigger MOSI MISO Select cursor Example CAN Event table Time of trigger DLC Data CRC Missing ACK Select cursor Identifier Example LIN Event table Time of trigger Identifier Checksum Er...

Страница 139: ...137 Example Parallel Bus Event table Time of event Event data...

Страница 140: ...ed file path Each event table is numbered sequentially from 0000 to 9999 For example the first event table will be saved as Event_Table0000 CSV the second as Event_Table0001 CSV and so on Event Table...

Страница 141: ...be added to the buses This label will appear next to the bus indicator on the left hand side of the display Panel Operation 1 To add a label to the bus press Edit Labels from the Bus menu 2 To choose...

Страница 142: ...t a number or letter Press Back Space to delete a character Press Editing Completed to create the new label and return to the previous menu Note this key must be pressed to save the label even for the...

Страница 143: ...ad bus values at any position Note Ensure that one of the serial buses has been selected and is activated Panel Operation 1 Press the Cursor key Horizontal cursors appear on the display Cursor 2 Press...

Страница 144: ...osition information appears on the top left hand side of the screen Example I2 C cursors Cursor Hor position Bus value s Cursor Hor position Bus value s 4 Use the Variable knob to move the movable cur...

Страница 145: ...gger Delay The Delay trigger works in tandem with the edge trigger by waiting for a specified time duration or number of events before the delay trigger starts This method allows pinpointing a locatio...

Страница 146: ...xtracts a sync pulse from a video format signal and triggers on a specific line or field Pulse and Runt Triggers on a runt A runt is a pulse that passes a specified threshold but fails to pass a secon...

Страница 147: ...Triggering point Bus Triggers on SPI UART I2C Parallel CAN or LIN bus events Logic Triggers on specified logic levels or for specified clock edge Logic trigger is only available for Digital channels...

Страница 148: ...Runt Rise Fall Bus and Logic Only for 2 input models EXT TRIG AC Line AC mains signal Except for Video Pulse Runt Rise Fall Bus and Logic D0 D15 Digital input channels Except for Video Pulse Runt Rise...

Страница 149: ...vents Select this mode especially when viewing rolling waveforms at slower timebases Normal The RSMSO 2000E 2000EA acquires a waveform only when a trigger event occurs Single When pressing the Single...

Страница 150: ...EVEL PUSH TO ZERO Set to TTL 1 4V Sets the trigger level to 1 4V suitable for triggering on TTL signals Set to ECL 1 3V Sets the trigger to 1 3V This is suitable for ECL circuits Set to 50 Sets the tr...

Страница 151: ...d the real trigger timing Event Sets the number of events 1 65535 passed after the trigger event until the real trigger timing Set to Minimum Sets the source trigger to the minimum time When Pulse Wid...

Страница 152: ...d levels for the digital sources from the Trigger menu will also change the threshold levels set in the Logic Analyzer menu page 207 Standard Video NTSC National Television System Committee PAL Phase...

Страница 153: ...RT Bus Tx Start Bit Rx Start Bit Tx End of Packet Rx End of Packet Tx Data Rx Data Tx Parity Error Rx Parity Error I2 C Start Repeat Start Stop Missing Ack Address Data Address Data SPI SS Active MOSI...

Страница 154: ...put signal stays high for a designated amount of time Stays Low Triggers when the input signal stays low for a designated amount of time Either Triggers when the input signal stays high or low for a d...

Страница 155: ...s to all the triggering types except the trigger by bus Wait for trigger Holdoff time Trigger point Next trigger point Panel Operation 1 Press the trigger Menu key Menu 2 To set the Holdoff time press...

Страница 156: ...triggering mode 3 Use the side panel to select Auto or Normal triggering modes Range Auto Normal Using the Edge Trigger Panel Operation 1 Press the trigger Menu key Menu 2 Press Type from the lower be...

Страница 157: ...coupling or frequency filter settings Choose the coupling from the side menu Range DC AC HF Reject LF Reject 7 Toggle Noise Rejection On or Off from the side menu Range On Off 8 From the bottom menu p...

Страница 158: ...L 3 7V 0V 0V Note Setting the trigger level for a digital source will also change the threshold levels set in the Logic Analyzer menu page 207 Using Advanced Delay Trigger Panel Operation 1 Set the ed...

Страница 159: ...ress Coupling from the bottom bezel menu to select the trigger coupling or frequency filter settings Choose the coupling from the side menu Range DC AC HF Reject LF Reject 7 To set the delay press Del...

Страница 160: ...ling 4 Press Source from the lower bezel 5 Use the side menu to select the pulse width trigger source Range Channel 1 4 Alternate On Off EXT Ext Probe Volt Current Attenuation 1mX 1kX CH2 models only...

Страница 161: ...channel Range 00 0V 5 screen divisions Set to TTL 1 4V Set to ECL 1 3V Set to 50 Digital channel Range 5 00V 5 00V TTL 1 4V 5 0V CMOS 2 5V 3 3V CMOS 1 65V 2 5V CMOS 1 25V ECL 1 3V PECL 3 7V 0V 0V Note...

Страница 162: ...he video trigger indicator appears at the bottom of the display From left source video standard field line coupling 4 Press Source from the lower bezel 5 Use the side menu to select the video trigger...

Страница 163: ...Field NTSC 1 262 PAL SECAM 1 312 HDTV 1 562 1080i All Fields Triggers on all fields All Lines Triggers on all lines 8 Press Polarity to toggle the polarity type Range positive negative Pulse Runt trig...

Страница 164: ...olarity to toggle the polarity Range Rising edge falling edge either 6 Press When from the lower menu Then use the side menu to select the condition and width Condition Width 4ns 10s 7 Press Threshold...

Страница 165: ...ttom of the display From left slope source high low threshold threshold level coupling 4 Press Source from the lower menu Use the side menu to select a source Range Channel 1 4 Alternate On Off 5 Pres...

Страница 166: ...Select Others Timeout from the side menu The Timeout indicator appears at the bottom of the display From left Source Trigger type threshold level coupling 4 Press Source from the lower menu Use the si...

Страница 167: ...ect 6 Toggle Noise Rejection On or Off from the Coupling side menu Range On Off 7 Press Trigger When from the lower menu Then use the side menu to select trigger conditions Condition Stays High Stays...

Страница 168: ...t to 50 Digital channel Range 5 00V 5 00V TTL 1 4V 5 0V CMOS 2 5V 3 3V CMOS 1 65V 2 5V CMOS 1 25V ECL 1 3V PECL 3 7V 0V 0V Note Setting the trigger threshold for a digital source will also change the...

Страница 169: ...Operation 1 Set the Bus to UART in the bus menu Page 119 2 Press the Trigger Menu key Menu 3 Press Type from the bottom menu 4 Press Others from the side menu and select Bus The Trigger on settings w...

Страница 170: ...g data To edit the data use the Variable knob to highlight a binary or hex digit and press Select Use the Variable knob to choose a value for the digit and press Select to confirm VARIABLE Binary 0 1...

Страница 171: ...bus Trigger On Start Repeat Start Stop Missing Ack Address Data Address Data Trigger On Data If Data or Address Data was configured for the Trigger On setting then the number of bytes data and address...

Страница 172: ...Address If Address or Address Data was configured for the Trigger On setting then the triggering address must be configured 10 Press Address on the bottom menu 11 Press Addressing Mode to toggle betwe...

Страница 173: ...elect to confirm VARIABLE Binary 0 1 X don t care Hex 0 F X don t care Direction 14 Press Direction on the bottom menu and choose the direction from the side menu Direction Write Read Read or Write SP...

Страница 174: ...ger On setting then the number of words and the data can be configured 6 Press Data from the bottom menu 7 Press Number of Words from the side menu and choose the number of words for the data SPI 1 32...

Страница 175: ...bottom of the display The Trigger on settings will be reflected on the Trigger Configuration icon From left Bus trigger Trigger source 5 Press Trigger On and select the triggering condition for the se...

Страница 176: ...ect Use the Variable knob to choose a value for the digit and press Select to confirm VARIABLE Binary 0 1 X don t care Hex 0 F X don t care 9 Press Direction on the bottom menu and select the CAN Dire...

Страница 177: ...en from the side menu to choose the triggering condition for the data When 14 The oscilloscope will now trigger when the specified bus data matches the Trigger When conditions LIN Bus Trigger The LIN...

Страница 178: ...tifier from the side menu to set the identifier data To edit the identifier use the Variable knob to highlight a binary or hex digit and press Select Use the Variable knob to choose a value for the di...

Страница 179: ...When from the side menu to choose the triggering condition for the data When 12 The oscilloscope will now trigger when the specified bus data matches the Trigger When conditions Parallel Bus Trigger T...

Страница 180: ...to choose a value for the digit and press Select to confirm VARIABLE Binary 0 1 X don t care Hex 0 F X don t care 7 The oscilloscope will now trigger when the specified data appears on the bus Using...

Страница 181: ...ect a logic level for the selected channel or set the selected channel as the clock signal Logic Clock High H Low L Don t Care X 7 Repeat steps 5 to 6 for the remaining channels 8 The chosen logic lev...

Страница 182: ...9 If a clock signal was defined press Clock Edge from the bottom menu and select a clock transition At each clock transition a comparison will be made Clock Edge Rising Falling Either 10 If no clock w...

Страница 183: ...specified logic appears among the digital channels Trigger Threshold Levels The trigger threshold levels for the digital channels can be assigned from a selected number of preset levels or a user defi...

Страница 184: ...182 rspro com 5 0V CMOS 2 5V 3 3V CMOS 1 65V 2 5V CMOS 1 25V ECL 1 3V PECL 3 7V 0V 0V 15 Press Threshold to set a user defined threshold Range 5 00V...

Страница 185: ...trigger system the Search events must first be configured before they can be found Luckily the trigger system configuration settings can also be used for the search events The types of searches are l...

Страница 186: ...tings for details Event Types Edge Pulse Width Runt Rise Fall Time FFT Peak Logic Bus No trigger equivalent 4 Select the source from which to search events Press Source from the bottom menu and select...

Страница 187: ...he trigger settings select Copy Search Settings to Trigger 3 To copy over the current trigger settings to the search settings press Copy Trigger Settings To Search Note If the settings cannot be copie...

Страница 188: ...ground The search events can be saved to the graticule display allowing you to superimpose new search events Search events are saved over the entire record length with a maximum of 1000 marks Save Mar...

Страница 189: ...Set Search Event 1 Navigate to a point of interest using the horizontal position knob or some other method POSITION PUSH TO ZERO 2 Press the Set Clear key Set Clear 3 A marker will be saved at the cen...

Страница 190: ...search function can support up to 10 000 events however only 1 000 events can be displayed on screen at once Panel Operation 1 Turn the FFT math function on Page 67 2 Press the Search menu key Search...

Страница 191: ...be seen as a search event The threshold level will be mirrored in the Threshold key Max Peak 1 10 Level 100db 100dB View Number of Peak Events To view the number of peak events set State Info to Mark...

Страница 192: ...e XXXX is a number starting from 0001 and is incremented each time the event table is saved 7 Press Event Table from the bottom menu and turn the Event Table function on The event table will appear on...

Страница 193: ...yed on the RSMSO 2000E 2000EA screen No Frequency and Value For example No Frequency Value 1 1 0000MHz 29 6dB 2 2 0000MHz 30 4dB 3 3 0000MHz 32 0dB Center Peak Results on Screen To shift the peak even...

Страница 194: ...the internal memory and access useful QR codes Select Menu Language Description The RSMSO 2000E 2000EA has a number of different languages to choose from Panel Operation 1 Press the Utility key Utilit...

Страница 195: ...er URL Erase Memory Background The Erase Memory function will erase all internal waveforms setup files and labels from internal memory Erased Items Waveform 1 20 Setting memory 1 20 Reference 1 4 Labe...

Страница 196: ...y Utility 2 Press Date Time on the lower menu 3 Set the Year Month Day Hour and Minute from the side menu Year 2000 2037 Month 1 12 Day 1 31 Hour 1 23 Minute 0 59 4 Press Save Now from the side menu t...

Страница 197: ...Comp on the lower menu 3 Press Frequency and change the frequency of the probe compensation signal Default Frequency 4 Press Default to set the frequency of the probe compensation signal to 1kHz defau...

Страница 198: ...f 3 from the side menu 4 Press QR Code from the side menu There will be two pages of QR codes to choose from Press Page 1 or Page 2 to navigate to each page 5 Use a QR code reader app on your smart ph...

Страница 199: ...Activating Digital Channels 201 Activate Digital Channels as a Group 201 Activate Individual Channels 202 Moving the Digital Channels or Creating Digital Channel Groups 203 Digital Channel Vertical Sc...

Страница 200: ...ple rate of 1GSa s with a bandwidth of 200MHz Supported Logic Thresholds TTL CMOS ECL PELC User defined The RSMSO 2000E 2000EA supports common logic thresholds and supports user defined thresholds of...

Страница 201: ...the probes are attached 2 Insert the Logic Analyzer probe GTL 16E into the Logic Analyzer slot input 3 Connect the ground lead from the logic analyzer probe marked G to the circuit ground on the DUT G...

Страница 202: ...ive analog waveform solid indicator Activated analog waveform transparent indicator Digital Channel Indicators Used to show the position and grouping of the digital channels Currently active digital c...

Страница 203: ...ff in groups of eight D0 D7 and D8 D15 Panel Operation 1 Press the Option key Option 2 Press Logic Analyzer from the bottom menu 3 Press D15 D0 On Off key 4 Select which group of digital inputs you wa...

Страница 204: ...2 Use the variable knob to highlight a channel or a group VARIABLE 3 A tick next to a particular channel or group indicates that the channel or group is currently on Channel 0 7 is on Channel 8 15 is...

Страница 205: ...r has two basic modes of operation for selecting or moving digital channels LA Select mode This mode is used to select digital channels that have already been activated LA Move mode This mode is used...

Страница 206: ...which mode is currently active Select The Move mode is used to move the digital channel position on the graticule as well as to group the channels If you turned on all the digital channels you will n...

Страница 207: ...position the selected channel group VARIABLE If you position the channel indicator over the next previous channel it will split the group into 2 Split the group above the selected channel Split the gr...

Страница 208: ...ove the indicator anywhere within that group 5 If you move the indicator outside of the group it will remove the selected channel from the group 6 Press the Select key again This will return you to th...

Страница 209: ...Note Threshold levels can be set to four groups of digital channels D0 D3 D4 7 D8 D11 and D12 D15 Each group can have a different threshold level The RSMSO 2000E 2000EA has 7 preset threshold levels...

Страница 210: ...et to select a pre set logic threshold Logic Type Threshold TTL 1 4V 5 0V CMOS 2 5V 3 3V CMOS 1 65V 2 5V CMOS 1 25V ECL 1 3V PECL 3 7V 0V 0V 4 Press Threshold to set a user defined threshold for the c...

Страница 211: ...nnel groups D0 7 and D8 15 Example Panel Operation 1 Press the Option key Option 2 Press the Analog Waveform key 3 Press Select and choose between Wave_A1 D7 D0 or Wave_A2 D15 D8 Display on Screen 4 P...

Страница 212: ...ound Digital labels can be added to each digital channel or to one of the analog waveforms Panel Operation 1 To edit labels for the digital channels press the Edit Labels soft key from the D15 D0 On O...

Страница 213: ...LE HALT INT IN IRQ LATCH LOAD NMI Edit Label 4 Press Edit Character to edit the current label 5 The Edit Label window appears 6 Use the Variable knob to highlight a character VARIABLE Press Enter Char...

Страница 214: ...o create a label even for a preset label Press Cancel to cancel the editing and return to the Edit Label menu 7 The label will appear next to corresponding channel indicator Below the label LABEL_7 wa...

Страница 215: ...ut On for the Selected Channel 217 Setting the Load Impedance 217 Setting the Phase 217 GEN1 and GEN2 Setup 218 Selecting a Waveform 218 Waveform Settings 219 AM Modulation 222 FM Modulation 224 FSK M...

Страница 216: ...n Lorentz Exp Rise Exp Fall Haversine Cardiac Functions AM FM FSK Sweep Rear Panel GEN1 output GEN2 output GEN 2 GEN 1 LINE VOLTAGE AC 100 240V RANGE FREQUENCY 50 60Hz POWER MAX 30 Watts CAUTION TO AV...

Страница 217: ...Status Indicators The AWG channel status indicators show the active channels output waveforms and function AWG status indicator Channel status indicator G1 G2 Waveform indicator of the indicated chan...

Страница 218: ...nu allows you to select a channel to turn the output on or off for the selected channel configure the load impedance and the phase of the output Select the Active Channel Background Before any operati...

Страница 219: ...r off Setting the Load Impedance Background The load impedance can be independently set for each generator channel Panel Operation 1 Press Load to toggle the impedance between 50 and High Z Setting th...

Страница 220: ...on has 14 selectable waveforms including a user created arbitrary waveform When using the modulation function the waveform selected here is also used as the carrier wave Panel Operation 1 From the AWG...

Страница 221: ...e GEN1 or GEN2 Setup menu 1 From the Waveform menu press Waveform Settings from the side menu Set the Frequency 2 Press Frequency to set the frequency rate of the waveform Note When Frequency is initi...

Страница 222: ...ncrease the amplitude by that base unit as shown in the Amplitude window 5 Default can be pressed to set the amplitude to 1 00Vpp 6 Press Go Back to leave the menu Range 10mVpp to 2 5Vpp Load 50 20mVp...

Страница 223: ...to increase the offset by that base unit as shown in the Offset window 9 Default can be pressed to set the Offset to 0 00Vdc 10 Press Go Back to leave the menu Range Default 1 25Vdc Load 50 2 5Vdc Lo...

Страница 224: ...ng waveform Example Panel Operation 1 Select the carrier waveform from the GEN1 Setup GEN2 Setup menu Press GEN1 Setup or GEN2 Setup for generator 1 or generator 2 respectively Press Waveform from the...

Страница 225: ...Freq to set the modulation frequency Frequency 200kHz 1Hz Shape 7 Press Shape to set the modulating wave shape Shape Sine square pulse ramp noise Phase Sine wave only 8 Press Phase to set the phase o...

Страница 226: ...ncy modulation can be used for either channel The carrier wave can only be sine square and ramp waveforms Sine square pulse ramp and noise can be selected as the modulating waveform Example Panel Oper...

Страница 227: ...Frequency Deviation 5 Press Freq Dev to set the frequency deviation Deviation 12 5MHz 0 1Hz Modulation Frequency 6 Press FM Freq to set the modulation frequency Frequency 200kHz 1Hz Shape 7 Press Sha...

Страница 228: ...exit the FM settings FSK Modulation Background Frequency shift keying modulation can be used for either channel The carrier wave is limited to sine square and ramp waveforms Sine square pulse ramp an...

Страница 229: ...SK modulation setup menu Set the Hop Freq 5 Press Hop Freq to set the hop frequency Hop Freq 25MHz 0 1Hz FSK Rate 6 Press FSK Rate to set the rate at which the waveform switches from the carrier and h...

Страница 230: ...EN2 Setup for generator 1 or generator 2 respectively Press Waveform from the bottom menu Select the waveform from the side menu Sweep Waves Sine square ramp 2 Press the Sweep from the bottom menu 3 F...

Страница 231: ...cy Span Alternatively the center frequency and span can be set instead of the start and stop frequencies 6 Press More 1 of 2 7 Press Span to set the frequency span of the sweep 8 Press Center to set t...

Страница 232: ...reate New ARB Waveform Background The Create New menu is used to load an inbuilt waveform with a defined length in order to build the shape of the arbitrary waveform Supported waveforms include Sine S...

Страница 233: ...Sine Square Pulse Ramp Noise 6 Press OK Create to create the arbitrary waveform shape Edit an Existing ARB Waveform Background Use the Edit Existing menu to edit a newly created waveform and further s...

Страница 234: ...line into the ARB waveform Diagonal Insert a diagonal line Scale Scales the ARB waveform vertically Copy Paste Copy or paste a section of the ARB waveform Clear Clears a section of the ARB waveform a...

Страница 235: ...memory If no waveform has been loaded a DC waveform is shown Normal Edit 4 Press Normal Edit to insert a point or delete a point from the waveform Insert Point To insert a point you must first set the...

Страница 236: ...point set with the Point soft key The overall length of the waveform will be shortened by one point Exit Normal Edit 5 Press Go Back to exit the Normal Edit Function Edit 6 Press Function Edit to perf...

Страница 237: ...igh Z b Press Length to set the length of the line Length 0 user defined point length c The Adjustment soft key can be used to toggle the step resolution of the variable knob when editing values in th...

Страница 238: ...igh Z b Press Point2 Level2 once to select the point s X axis end point Press Point2 Level2 again to select the amplitude Level of the end point Point2 1 user defined point position Level2 1 25Vdc Loa...

Страница 239: ...eform exceeds the maximum amplitude it will be clipped Scale 0 1x 10X b Press Go Back to go back to the previous menu Copy Paste a Press Start to set the start point of the section you want to copy b...

Страница 240: ...e screen e Press Done to confirm the edit or press Undo to cancel f Press Go Back to go back to the previous menu Clear Section a Press Start to set the start point of the section you want to clear Pr...

Страница 241: ...m from the GEN1 Setup GEN2 Setup menu Press GEN1 Setup or GEN2 Setup for generator 1 or generator 2 respectively Press Waveform from the bottom menu Select Arbitrary from the side menu 2 Press Wavefor...

Страница 242: ...knob to select the desired ARB waveform Press the Select key to load the selected ARB waveform in the file utilities screen Select Note Press File Utilities to manage the files on the internal disk or...

Страница 243: ...B waveform to save ARB Arb1 Arb2 Arb3 Arb4 Press Save to save the waveform to the selected memory slot Arb1 Abr2 Arb3 or Arb4 5 Alternatively to save to a USB drive or to the internal flash memory pre...

Страница 244: ...you to the Save Waveform menu After Save Now has been pressed the file will be saved Note The file will not be saved if the power is turned off or the USB drive is taken out before the message ends Fi...

Страница 245: ...om the side menu to reset both wave generators to a 0V DC waveform 2 Press Dual Chan from the side menu to enter the coupling and tracking menus Tracking settings 3 From the side menu press Tracking t...

Страница 246: ...ss Offset on the side menu to configure the offset of the frequency coupling 7 Use the Left and Right arrow keys to select a base unit and use the variable knob to increase or decrease the offset by t...

Страница 247: ...ency Coupling cannot be set if Tracking is ON Configuring Frequency Coupling parameters will disable the Tracking mode Amplitude coupling 15 Press Ampl Cpl to set the amplitude coupling to ON or OFF A...

Страница 248: ...ons 248 Go NoGo application 249 DVM application 254 Data Log application 256 Digital Filter application 258 Mask application 260 Select the source channel 260 Configure the mask violation 261 Auto Mas...

Страница 249: ...inside a user specified maximum and minimum amplitude boundary template DVM The DVM application displays a digital voltage meter readout that floats on the top left hand side of the screen Data Log Th...

Страница 250: ...board Running Applications Background The RSMSO 2000E 2000EA comes pre installed with a number of apps which can be activated from a dedicated menu Panel Operation 1 Press the APP key APP 2 Press APP...

Страница 251: ...itions can be set Choose the Go_NoGo application from the APP menu See page 248 Set Go NoGo Conditions Select the Go NoGo conditions NG When and actions when a Go NoGo condition has been met Violating...

Страница 252: ...lations and continue to monitor the signal Each violation is counted 4 Press Go Back to return to the previous menu Set Go NoGo Source 5 Press Compare Source from the bottom menu to set the Go NoGo bo...

Страница 253: ...position or Range Voltage division range Save Boundary Template 10 Press Save Operation to save the tolerance boundaries 11 The Maximum Position tolerance will be saved to reference waveform R1 and t...

Страница 254: ...ication To exit the application press Break Note After you exit the Go NoGo app the boundary templates that were saved to R1 R2 reference waveforms will still be turned on See page 292 to turn the ref...

Страница 255: ...253 Timing Diagram Enable NoGo 500us Waveform Circuit Diagram Go NoGo signal 220 Go NoGo BNC B CMOS Max 16V Or TTL Max 5V...

Страница 256: ...cursor readout The DVM app allows you to measure the AC RMS DC DC RMS Duty and frequency of an input signal This software is especially useful for those measurement applications that require both a D...

Страница 257: ...function acts as a digital voltmeter or as a digital current meter for the selected source See page 113 to set the probe type Source CH1 CH4 Mode The Mode setting determines the measurement mode for...

Страница 258: ...time Basic Features Log up to 100 hours of images or waveform data Interval times of up to 2 seconds waveform or 5 seconds images Example Panel Operation Choose the Data Log application from the APP m...

Страница 259: ...time Duration 5mins 100hrs 6 From the bottom menu press File Utilities and set the save file path See the File Utilities chapter page 294 for details Turn On Off 7 Press Data Logging from the bottom m...

Страница 260: ...ble to the Digital channels Basic Features High pass or low pass filtering of analog channels Selectable cutoff frequencies Tracking function Example Digital filter type or status High pass filter exa...

Страница 261: ...ff frequency Likewise if High Pass was selected press Lower Limit to set the high pass cutoff frequency Only one option will be available at a time Upper Limit 1Hz 500MHz Lower Limit 1Hz 500MHz Tracki...

Страница 262: ...d shape Panel Operation Choose the Mask application from the APP menu See page 248 Select the source channel Step 1 Press the Compare Source button from the bottom menu 2 Press the CH1 button from the...

Страница 263: ...he source waveform crosses the mask boundary mask violation condition Conversely press the Continue button to continue acquiring data even when a mask violation condition is encountered 3 Toggle the S...

Страница 264: ...erence source CH1 or CH2 for 2 channels model and CH1 CH4 for 4 channels models 4 Press the Edit button from the side menu if you want to further adjust the mask pattern Otherwise go to step 9 below t...

Страница 265: ...to adjust the horizontal deviation of the mask compared to its original pattern 7 Press the Y Mask button from the side menu and use the Variable knob to adjust the vertical deviation of the mask comp...

Страница 266: ...hown in the below diagram and can now be used 10 Press the Auto Mask button from the bottom menu to close auto mask function 11 Press the Mask ON button from the bottom menu to execute the mask functi...

Страница 267: ...and juxtaposed to each other to form the user defined mask pattern Step 1 Press the User Define button from the bottom menu 2 Press the Edit button from the side menu Create an area 3 Press the Area N...

Страница 268: ...d Edit the first point 6 Press the Points Number button from the side menu and use the Variable knob to select the first point that will shape the area pattern Up to 10 points can form an area pattern...

Страница 269: ...the Edit Points menu Create other areas 11 Repeat the above steps for as many areas as you need to create your mask pattern 12 Press the Go Back button again from the side menu 13 Press the Create Ma...

Страница 270: ...he Variable knob to select the file and press the Select key twice to load the mask Select VARIABLE User defined Mask File Format Background The user defined mask files can be created out of support f...

Страница 271: ...269 Example with Division units Format 2 0E Total Area Number 2 Area Number 1 Points Number 4 0 00 2 00 1 00 1 00 0 00 0 00 1 00 1 00 Area Number 2 Points Number 3 0 00 2 00 1 00 1 00 1 00 1 00...

Страница 272: ...272 Setup File Format 274 Create Edit Labels 276 Save 279 File Type Source Destination 279 Save Image 280 Save Waveform 282 Save Setup 284 Recall 286 File Type Source Destination 286 Recall Default P...

Страница 273: ...LSF file format efficiently stores waveforms This is the file format used for storing and recalling all waveforms that are used with the RSMSO 2000E 2000EA series except digital channel waveforms File...

Страница 274: ...eet applications such as Microsoft Excel CSV formatted files can be stored in either a short memory format or a long memory format Detail CSV Fast CSV The number of points that are saved depends on th...

Страница 275: ...V where applicable Format scope type Memory length Trigger Level Source Label Probe ratio Vertical units Vertical scale Vertical position Horizontal units Horizontal scale Horizontal position Horizont...

Страница 276: ...are Time Mode Raw vertical waveform data Setup File Format Format DSxxxx set proprietary format The setup file saves or recalls the following settings Contents Acquire Mode Sample rate XY Sample mode...

Страница 277: ...n Unit Div Math Off FFT Math Source Vertical Units Window Vertical position Horizontal position Advanced Math Expression VAR1 VAR2 Position Unit Div Trigger Type Source Coupling Alternate Rejection No...

Страница 278: ...ference files setup files or channels when saving or recalling waveforms and setups Example Label for CH1 Label for Ref 1 In the example above the file label for channel 1 is displayed next to the cha...

Страница 279: ...10 4 To choose a preset label Press User Preset from the side menu and choose a label Labels ACK AD0 ANALOG BIT CAS CLK CLOCK CLR COUNT DATA DTACK ENABLE HALT INT IN IRQ LATCH LOAD NMI Edit Label 5 Pr...

Страница 280: ...rn to the previous menu To cancel the editing the label and return to the previous menu press Cancel Display Label To display the currently selected file label on the screen next to its respective ind...

Страница 281: ...ll displayed waveforms Internal memory Reference waveform Ref1 4 Wave1 Wave20 File system Disk USB Display Image DSxxxx bmp png Axxx1 bmp png Display image File system Disk USB Stored in ALLXXXX direc...

Страница 282: ...front panel USB port If a USB drive is not connected images can still be saved to the internal memory Front Panel 2V 2 Press the Save Recall key from the front panel Save Recall 3 Press Save Image fro...

Страница 283: ...key to select a number or letter Press Back Space to delete a character 9 Press Save Now to save the file The file name need not have been edited to save the file Note Pressing Cancel will cancel the...

Страница 284: ...the drive to the front panel USB port If a USB drive is not connected files can still be saved to the internal memory Front Panel 2V 2 Press the Save Recall key from the front panel Save Recall 3 Pres...

Страница 285: ...to delete a character 9 Press Save Now to save the file The filename need not have been edited to save the file Note Pressing Cancel will cancel the save operation and return you to the Save Recall m...

Страница 286: ...t panel Save Recall 3 Press Save Setup from the bottom menu 4 Press To internal memory or To File and choose a destination to save to To Set1 Set20 To File DSxxxx set 5 Press Save to confirm saving Wh...

Страница 287: ...return you to the Save Recall menu After Save Now has been pressed the file will be saved Note The file will not be saved if the power is turned off or the USB drive is taken out before the message en...

Страница 288: ...ont panel Panel Setup DSxxxx set Internal memory S1 S20 File system Disk USB Current front panel Waveform Data DSxxxx lsf DSxxxx csv CH1 CH4 lsf Ref1 Ref4 lsf Math lsf Internal memory Wave 1 Wave20 Fi...

Страница 289: ...Waveform intensity 50 Graticule intensity 50 Backlight Intensity 80 Backlight Auto dim On Time 10min Graticule full Channel Scale 100mV Div CH1 On Coupling DC Impedance 1M Invert Off Bandwidth full E...

Страница 290: ...Horizontal 5MHz div Advanced Math Expression CH1 CH2 VAR1 0 VAR2 1 Position 0 00Div Unit div 500mV APP App Go NoGo DVM Datalog Mount Remote Disk Trigger Type Edge Source CH1 Coupling DC Alternate Off...

Страница 291: ...ress Recall Waveform from the bottom menu The Recall menu appears 5 Press From internal memory or From File and choose a source to recall from From Wave1 20 From File File format Lsf Fast Csv Only fil...

Страница 292: ...o edit USB flash drive contents create delete rename files and folders or to set the file path press File Utilities Recall Setup Panel Operation 1 For recalling from an external USB flash drive Connec...

Страница 293: ...d a message appears at the bottom of the display Note The file will not be recalled if the power is turned off or the USB drive is taken out before the message appears File Utility To edit the interna...

Страница 294: ...veforms as reference waveforms 1 Press the REF key on the front panel REF R 2 Pressing R1 R4 repeatedly will toggle the corresponding reference waveform OFF ON Turning R1 R4 ON will open the correspon...

Страница 295: ...the Time Div or the horizontal position Use the Variable knob to edit the value View Reference Waveform Details Pressing Ref Details will display the reference waveform details Details Sample Rate Re...

Страница 296: ...e file utilities can create delete and rename directories or files as well as copy files from internal memory to USB The File Utilities menu also sets the file path for saving and recalling files from...

Страница 297: ...used to choose files or to set the file path for saving recalling files File System File path Drive space File cursor File attributes Panel Operation 1 Press the Utility key Utility 2 Press File Utili...

Страница 298: ...SB flash drive is used This saves you the hassle of setting the USB file path each time the USB flash drive is inserted into the scope Create Folder Panel Operation 1 Press the Utility key Utility 2 P...

Страница 299: ...ete a character 6 Press Save Now to create the folder Cancel Press Cancel to cancel the operation Rename File Panel Operation 1 Press the Utility key Utility 2 Press File Utilities from the bottom men...

Страница 300: ...letter Press Back Space to delete a character 6 Press Save Now to rename the folder or file Delete File or Folder Panel Operation 1 Press the Utility key Utility 2 Press File Utilities from the botto...

Страница 301: ...t Panel 2 2 Press the Utility key Utility 3 Press File Utilities from the bottom menu 4 Use the Variable knob and Select key to navigate the file system to choose a file from internal memory 5 Press C...

Страница 302: ...pressing the Hardcopy key can be used to save a screen shot a waveform or the current setup depending on the configuration Printer I O Configuration Panel Operation 1 Connect a PictBridge printer to t...

Страница 303: ...see page 300 Panel Operation 1 Press the Utility key Utility 2 Press Hardcopy from the bottom menu 3 On the side menu press Function and select Print 4 Press the Hardcopy key to print The display imag...

Страница 304: ...connect a USB drive to the front panel USB port otherwise the file will save to internal memory Front 2V 2 Press the Utility key Utility 3 Press Hardcopy from the bottom menu 4 On the side menu press...

Страница 305: ...or image files set Ink Saver to On Ink Saver On Ink Saver Off Note Each time the Hardcopy key is used to save waveforms or setup files the files are saved into a new directory The save directory is la...

Страница 306: ...hapter describes basic configuration for remote control Interface Configuration 305 Configure USB Interface 305 USB Functionality Check 306 Configure the Ethernet Interface 307 Configure Socket Server...

Страница 307: ...lity 2 Press I O from the bottom menu 3 Press USB Device Port from the side menu and select Computer 4 Connect the USB cable to the rear panel device port 5 When the PC asks for the USB driver select...

Страница 308: ...OM port number and associated port settings see the Device Manager in the PC For Windows 7 Control panel Hardware and Sound Device Manager Example Configuring RealTerm Functionality Check Key in this...

Страница 309: ...rol using a socket server connection For details please see the Socket Server section on page 309 Panel Operation 1 Connect the Ethernet cable to the LAN port on the rear panel 2 Press the Utility key...

Страница 310: ...Items MAC Address Instrument Name User Password Instrument IP Address Domain Name DNS IP Address Gateway IP Address Subnet Mask Note HTTP Port is fixed at 80 7 Use the Variable knob to highlight a ch...

Страница 311: ...the Socket Server is off Configure Socket Server 1 Configure the IP address for the RSMSO 2000E 2000EA Page 307 2 Press the Utility key Utility 3 Press I O from the bottom menu 4 Press Socket Server f...

Страница 312: ...ebsite www ni com Operation 1 Configure the IP address for the RSMSO 2000E 2000EA Page 307 2 Configure the socket port Page 309 3 Start the NI Measurement and Automation Explorer MAX program Using Win...

Страница 313: ...Raw Socket from the popup window 7 Click Next 6 7 8 Enter the RSMSO 2000E 2000EA s IP address and socket port number 9 Click Validate 10 A popup will appear to tell you if a VISA socket session was su...

Страница 314: ...10 11 8 9 12 Choose an alias for the socket connection if you like 13 Click Finish to finish the configuration 12 13 MSO 14 The RSMSO 2000E 2000EA will now appear under Network Devices in the Configu...

Страница 315: ...mote command to the RSMSO 2000E 2000EA 14 15 RSMSO 2000E 16 Click on the Configuration icon 17 Select the I O Settings tab 18 Mark the Enable Termination Character checkbox Make sure the termination c...

Страница 316: ...uery is selected in the Select or Enter Command drop box 22 Click on Query 23 The manufacturer model number serial number and firmware version will be displayed in the buffer For example RS PRO RSMSO...

Страница 317: ...re available Signal Path Compensation Vertical Accuracy Calibration and Probe Compensation Run these operations when using the RSMSO 2000E 2000EA in a new environment How to use the SPC function 316 V...

Страница 318: ...key Utility 2 Press System from the bottom menu 3 Press SPC from the side menu A message showing a brief introduction to SPC appears on the screen Note Disconnect all probes and cables from all channe...

Страница 319: ...ss more 1 of 3 from the side menu 4 Press Self Cal on the side menu 5 Press Vertical on the side menu 6 A message appears to Now performing vertical calibration CH1 Connect the CAL output to channel t...

Страница 320: ...for Channel 2 3 and 4 when prompted 4 channel models only 10 When the calibration for all channels has completed the display goes back to the default state Probe Compensation Panel Operation 1 Connect...

Страница 321: ...TO ZERO PUSH TO ZERO SCALE POWER CH1 CH2 CH3 CH4 2V CAT I 1M W 16pF 300Vrms MAX x1 x10 X10 X1 CH1 2V 3 Press the CH1 key to activate CH1 CH1 4 Set the Coupling to DC from the bottom menu 5 Set the Pro...

Страница 322: ...320 rspro com 8 Turn the adjustment point on the probe to make the waveform as square as possible Under Compensation Normal Over Compensation...

Страница 323: ...ed the signal but it does not appear on the display Make sure you have activated the channel by pressing the Channel key the channel key lights up I want to remove the Measurement result FFT result He...

Страница 324: ...is distorted You might need to compensate the probe For details see page 318 Autoset does not catch the signal well The Autoset function cannot catch signals under 10mV or 20Hz Please use the manual...

Страница 325: ...323 The accuracy does not match the specification Make sure the device is powered On for at least 30 minutes within 20 C 30 C This is necessary to stabilize the unit to match the specification...

Страница 326: ...spro com APPENDIX Updating the Firmware 325 RSMSO 2000E Specifications 327 Model specific 327 Common 328 Probe Specifications 332 GTP 100B 4 332 GTP 200B 4 332 Dimensions 333 Declaration of Conformity...

Страница 327: ...panel 2 2 Press the Utility key Utility 3 Press File Utilities from the bottom menu 4 Use the Variable knob to highlight the upgrade file 5 Press the Select key to begin the installation of the upgrad...

Страница 328: ...326 rspro com 7 Wait for the installation process to complete When the installation has completed you will be prompted to restart the oscilloscope Remove the USB drive and proceed to the restart...

Страница 329: ...Channels 2 Ext Bandwidth DC 100MHz 3dB Rise Time 3 5ns Bandwidth Limit 20MHz RSMSO 2104E 2104EA Channels 4 Bandwidth DC 100MHz 3dB Rise Time 3 5ns Bandwidth Limit 20MHz RSMSO 2202E 2202EA Channels 2 E...

Страница 330: ...r RMS or dBV RMS and FFT Window to Rectangular Hamming Hanning or Blackman Harris Trigger Source CH1 CH2 CH3 CH4 Line EXT D0 D15 four channel models only two channel models only Trigger Mode Auto supp...

Страница 331: ...FPREShoot Frequency Period RiseTime FallTime Width Width Duty Cycle Pulses Pulses Edges Edges Flicker Flicker Idx FRR FRF FFR FFF LRR LRF LFR LFF Phase Cursors measurement Voltage difference between c...

Страница 332: ...Memory 2G bits Input Channels 16 Digital D15 D0 Trigger type Edge Pattern Pulse Width Serial bus I2C SPI UART CAN LIN Parallel Bus Thresholds Quad Settable thresholds for D0 D3 D4 D7 D8 11 D12 15 Thr...

Страница 333: ...en collector output Kensington Style Lock Rear panel security slot connects to standard Kensington style lock Miscellaneous Multi language menu Available Operation Environment Temperature 0 C to 50 C...

Страница 334: ...Capacitance 85pF to 115pF Max Input Voltage 200V DC ACpk Operating Cond Temperature 10 C to 50 C Relative Humidity 85 GTP 200B 4 Applicable to RSMSO 2202E 2202EA RSMSO 2204E 2204EA Position X10 Attenu...

Страница 335: ...Help APP Save Recall Acquire Utility Autoset Run Stop Single Default Select Search Set Clear Zoom Menu 50 Force Trig POSITION POSITION VERTICAL MATH REF BUS SCALE SCALE PUSH TO ZERO PUSH TO ZERO M R...

Страница 336: ...e following standards were applied EMC EN 61326 1 EN 61326 2 1 Electrical equipment for measurement control and laboratory use EMC requirements 2013 Conducted and Radiated Emissions EN 55011 2009 A1 2...

Страница 337: ...60 Autoset 44 AC Priority mode 45 effect on channel 45 exception 45 Fit Screen mode 45 AWG AM 232 channel activation 226 connection 225 Coupling and tracking 253 Create new ARB waveform 240 edit exist...

Страница 338: ...gger 161 EN61010 measurement category 8 pollution degree 9 Erase memory 202 Ethernet interface 321 Expand by ground center 119 External trigger 153 input terminal 24 specification 342 FAQ 335 FFT hori...

Страница 339: ...igger 165 QR code reader function 204 Rear panel diagram 26 224 Recall 299 default setup 300 reference 305 setup 303 waveform 302 Rectangular window 75 Reduce any menu 39 Reduce lower menu 39 Reduce s...

Страница 340: ...UART 175 edge 161 holdoff 160 indicator 29 logic 187 mode 161 parameters 153 pulse runt 169 pulse width 165 Rise and fall 171 Single 46 specification 342 status indicator 30 Timeout 172 overview 159 v...

Страница 341: ...ea Business Centre Phase 2 NO 618 Yan an Eastern Road Shanghai 200001 China Europe RS Components Ltd PO Box 99 Corby Northants NN17 9RS United Kingdom Japan RS Components Ltd West Tower 12th Floor Yok...

Страница 342: ...340 rspro com...

Отзывы: