15
or tilt motor will fails to work normally. If pan or tilt works abnormally, try stop
this function temporarily. Pan and tilt will run normally without this function but,
it will increase the amount of reset time, and cause more impacts between the
limit structures, and the positional errors will not be corrected automatically
when the step motors lose step. This menu option only take effect when reboot
the system.
Allow DMX save:
If select "Yes"
,
the setting values from functions DMX channel(6/4/6) will
be saved to EEPROM, that is, The setting value will be retained for the next
time when you reboot the system(This menu selection is valid for all the
settings in the function channel except for the "Run mode").
Clear Lamp Time:
Use the menu to reset the counter of operation hours with the lamp to 0,
when a new lamp replaces the old one.
Recover Setting:
Use the menu to reset factory settings. But the information like fine tuning
of motor, lamp switch state, user programs, lamp on time, will not be
resettled.
Please note that do not perform this Operation when the motors is rotating
with high speed because it will tack relatively long time to write the EEPROM.
Info:
DMX Monitor:
Display the DMX value from controller
Chn:
Use the menu to select desired channel which you need to watch.
Value:
Show the current value of the selected channel
State Monitor:
Display current running status
CPU1 TEMP
℃
:
The menu shows the temperature of the CPU which is in the fixture
base.
CPU2 TEMP
℃
:
The menu shows the temperature of the CPU witch is in the fixture
head.
Lamp TEMP
℃
:
Shows the monitoring points temperature of the lamp. If the
temperature is lower than 0
℃
or there is no temperature sensor for
digital detection(temperature sensor is fitted on some models only),it
will shows "Invalid".
Battery (%):
Shows the battery capacity in percentage (notes that only some models
are fitted with battery).
Lamp Service time:
Lamp service time
ThisTime (m):
The menu shows the total number of the operation minutes with the
lamp on currently.
Total(h):
The menu shows the total number of the operation hours with the lamp on
since the last operation of clear.
Err State:
Error information (If there is any error shown in this menu, a exclamatory mark will
show at the top right corner of menu cover)