Warnings Table
01
02
03
04
05
06
SN
Warning
type
Value threshold
The pressure is higher than standard about 40%
The pressure decrease over 0.2Bar in 20 seconds
The pressure is lower than standard about 25%
The temperature of tire is over 80
The power of any transmitter is less than 2.4V
Missing some transmitter messages over 20 minutes after ON
High pressure warning
Leakage warning
Low pressure warning
High temperature warning
Low power of transmitter warning
No signal warning
Unit conversion
Pressure unit conversion: 1kg/cm2= 0.98Bar= 14.2PSI = 98.0665kpa
Air pressure equals 1.03327 kg/cm2
Temperature unit conversion: C=5/9
F-32
F=9/5C+32
Note: C means Celsius; F means Fahrenheit
TECHNICAL SPECIFICATIONS
INSTALLATION
Receiver Installation
The receiver should be attached to the dash surface using double-side
tape, where the driver can see it easily.
Correctly connect the cable:
Red wire
12V
connect to the electric cell
White wire
ON
Black wire
GND
GND
B ATTE R Y
BLACK
RED
KEY ON
WHITE
16
1 7
Technical Specifications
A) Receiver:
Power supply: DC 12V
3V
Working temperature: -40
~ +85
LCD
-20
~ +70
B) Transmitter:
Power supply: DC2.1-3.6V
Working frequency: 433.92MHZ
Iddle currency: <18mA
Working frequency: 433.92MHZ