USERS INSTRUCTIONS

Description

This Royal Cozy Fires Decorative Fuel Effect gas fire has been developed to give a realistic coal burning appearance with
the instant control and convenience of gas. The fire has been constructed to enable it to be installed into most applications
(using the optional spacer frame) where the warmth and comfort of an open fire with high radiant heat is required. This
appliance is intended for decorative purposes and the coal bed uses ceramic simulated (coals) to give a realistic
appearance and to allow secondary air to be entrained into the bed to ensure clean combustion. An aerated single ported
steel burner is used running parallel across the front of the fire. A combined gas control and piezo igniter with a variable
high to low setting is used, this is fitted with a Flame Supervision Device (FSD).  This is to ensure that should the pilot
flame be extinguished for any reason, (including turning off the appliance) the gas supply to the burner is cut off until a
full lighting sequence is repeated. The Piezo igniter is used to ignite an Oxy-Pilot sensor (ODS) which will cause the
appliance to (shut off) in the event of continued spillage occurring under hazardous or blocked flue conditions. The fire
bed consists of ceramic fibre components and coals all of that are removable for cleaning purposes when required. It is
important when relaying the coal-bed and coals to follow the instructions correctly.

This appliance is suitable for installations into the following flues:

7" minimum diameter flues (CLASS 1)
5" minimum diameter flues (CLASS 2),
Pre-cast flues to BS 1289 Pt 1 1986 (when spacer frame is fitted).

The installations must always be used in conjunction with a suitable hearth and surround (refer to page 5 for further
details).

Important Notes

A hearth must always be provided to project forwards of the brass trim a minimum of 300mm and a minimum of 150mm
either side of the fire opening. The hearth must be a minimum thickness of 12mm with a perimeter height of 50mm to
deter combustible materials, carpets etc., being placed on the hearth. The area under the firebox must have a minimum
non-combustible thickness of 25mm.

The appliance is fitted with an ODS, a spillage monitoring system which operates if the evacuation of products is
interrupted (i.e. blocked or incorrect flueing). If the gas fire repeatedly ‘goes out’ it may indicate a problem and the
installer or specialist should be informed before further use.

Areas of this appliance will become hot after prolonged running and it is recommended that for the protection of the very
young, elderly and infirm a fireguard conforming to BS 6539 or BS 6778 be used.

Care should be taken to prevent any damage being caused to surrounding soft furnishings or decor e.g. many embossed
vinyl wall coverings may become discoloured if located close to the appliance. Clearances required for combustible
shelves are shown in page 3.

Care should be taken to ensure that when the appliance is installed into a Pre-cast flue, the chimneybreast is lined to
prevent the plaster etc. cracking through excessive temperatures.

In most installations a back panel will be required, this will also need a minimum fire resistance rating of Class O (100

 O

C).

This product uses fuel effect pieces, gaskets and insulation material containing Refractory Ceramic Fibre (RCF), which
are man-made vitreous silicate fibres. Excessive exposure to these materials may cause temporary irritation to eyes, skin
and respiratory tract, consequently, it makes sense to take care when handling these articles to ensure that the release of
dust is kept to a minimum.

A range of fronts and frets are available for use with this appliance, these have perforated frets to allow air to be drawn
into the coal bed for combustion and over the controls for cooling purposes. If other fronts and frets are to be used they
must have a minimum open area in the fret of 20sq cms and 60sq cms in the front. See Fig. 11.

The chimney or flue (unless new) must be swept before installation. It should be checked annually for satisfactory
clearance of products and that there is no excessive build up of soot.

TO LIGHT THE APPLIANCE

1.

 

Remove the Fret (Controls cover), to gain access to the controls.

2.

 

Press and turn the gas control anti-clockwise, keep the control fully depressed. The igniter will operate and the pilot will
light, if not repeat the operation.

Page 2

Содержание Gas Fire

Страница 1: ...SS 2 FLAME SYSTEM 3 USERS Pages 2 3 INSTALLATION Pages 4 9 AND SERVICING INSTRUCTIONS THIS CAT I2H APPLIANCE IS FOR USE ON NATURAL GAS G20 AT A SUPPLY PRESSURE OF 20 mbar IN GB and IE HAND THESE INSTRUCTIONS TO THE USER ...

Страница 2: ...er the firebox must have a minimum non combustible thickness of 25mm The appliance is fitted with an ODS a spillage monitoring system which operates if the evacuation of products is interrupted i e blocked or incorrect flueing If the gas fire repeatedly goes out it may indicate a problem and the installer or specialist should be informed before further use Areas of this appliance will become hot a...

Страница 3: ...leaned off using a non fluffy cloth Laying the Coal Bed The coal support shelf is positioned on the fibre support metalwork ensure that the shelf sits against the two stops which are to prevent the shelf sitting on the burner outlet Place the simulated coal front in position as shown in Fig 6 three tabs are provided to locate The one piece coal support shelf is constructed to allow three levels of...

Страница 4: ... 6461 Pt 1 1984 BS 715 1993 BS 1289 Pt 1 1986 BS 7566 Pts 1 4 1992 Technical Data Overall height of fire with spacer 612mm Overall height of fire without spacer 605mm Minimum height of opening required 540mm Maximum height of opening with spacer 590mm Maximum width of opening required 405mm Maximum width of opening with spacer 470mm Forward projection from opening 60mm without front and fret Forwa...

Страница 5: ... must not restrict the above listed flues The flue must only service a single appliance and not have any branches or traps that may impede the natural draught Any flue damper plate or restrictor shall be removed or fixed in the fully opened position The front and base of the fire opening must be flat and square to ensure a good seal with the appliance this is to ensure that there is no reduction i...

Страница 6: ...he requirements of BS 6891 1988 dealing with enclosed pipes The Standard requires that when a gas pipe is fed through a wall the pipe should be enclosed in a tight sleeve to protect against failure caused by movement It shall be constructed to prevent passage of gas either between the pipe and sleeve or sleeve and wall Where a gas supply pipe enters the box in any of the positions stated the hole ...

Страница 7: ...extra thickness to be added where it is necessary to effect a seal on uneven surfaces Remove the backing strip covering the adhesive surface of the strip and position onto the rear of the firebox or the spacer frame where applicable Before offering the vent box into the opening the hearth should be protected from damage or scratches that may occur during installation Locate and secure the vent box...

Страница 8: ...fan is situated in the room this test should be repeated with the fan running If there is a connected room with an extractor fan the test should be repeated with all the doors to that room opened and the extractor fan running All smoke must be drawn into the flue If spillage occurs allow a further 10 minutes Should spillage still occur examine the chimney for the fault and rectify Check for satisf...

Страница 9: ...xing flange When refitting observe that the two feet at the rear of the assembly locate under the two lugs formed in the base of the box assembly i TO CLEAN OR REPLACE THE INJECTOR Unscrew the compression nut connecting the gas supply to the elbow injector while supporting the injector to prevent distortion of the framework Unscrew and remove the gas supply tube from the gas control valve hold the...

Страница 10: ...Page 10 ...

Страница 11: ...he surround with the sapcer fitted to satisfy the debris collection requirement Depth B is Nominally 70mm If no chairbrick is fitted the minimum distance required between the rear of the opening and the front face of the surround is 210mm without spacer frame fitted Page 11 ...

Страница 12: ...Page 12 ...

Страница 13: ...Page 13 ...

Страница 14: ...Page 14 ...

Страница 15: ...Page 15 ...

Страница 16: ...Page 16 ...

Страница 17: ...Page 17 ...

Отзывы: