Royal Sovereign RDHC-110 Скачать руководство пользователя страница 4

4

IMPORTANT SAFETY INSTRUCTIONS

Read all instructions before use

Your safety and the safety of others is very important.

We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages. 

This is the safety alert symbol. This symbol alerts you to potential hazards that can hurt you and others.

All safety messages will follow the safety alert symbol and either the word "WARNING" or "CAUTION". These words mean:

   

WARNING This symbol indicates the possibility of death or serious injury.

   

CAUTION This symbol indicates the possibility of injury or damage to property.

Basic safety precautions

 

WARNING   

To reduce the risk of fire, electric shock, or injury to persons when using this appliance, follow basic precautions, including the following:

•  Do not attempt to repair or replace any part of your dehumidifier unless it is specifically recommended in this manual. All other services should be referred to a qualified technician.

• If the power cord becomes worn or damaged, the cord should only be replaced by a qualified service technician using genuine replacement parts.

• The dehumidifier should be plugged into its own grounded (13A, 60Hz, 115VAC circuit) .

• Do not plug other appliances into the same outlet; it can overload the circuit and cause a fire or electric shock.

• Do not remove the round grounding prong from the plug. It can result in the risk of electric shock.

• This appliances is not designed for use by young children. Young children should be supervised to ensure that they do not play with or climb on the unit.

• Be sure all packaging materials are removed from the appliances before use. It can result in personal injury.

• Do not disassemble or modify the appliances or the power cord. It can result in the risk of electric shock or fire.

• Do not place the power cord or appliances near a heater, radiator, or other heat source. It can result in the risk of electric shock or fire.

•  Do not use this or any appliance near flammable gases or liquids or other combustibles, such as gasoline, benzene, thinner, etc. It can result in the risk of electric shock or fire.

• Make sure the power cord is plugged firmly and completely into the outlet. It can result in the risk of electric shock or fire.

• Do not start or stop operation by plugging in or unplugging the power cord. It can result in the risk of electric shock.

• If the appliances are making unusual sounds or is emitting smoke or an unusual odor, unplug it immediately. It can result in the risk of electric shock or fire.

• Do not use if the electrical socket is loose or damaged. It can result in the risk of electric shock or fire.

• Do not operate with wet hands or in a excessive damp environment. It can result in the risk of electric shock.

• Do not use this or any electrical appliance if you smell gas. It can result in the risk of fire or explosion.

• Turn off and unplug the appliances before cleaning to avoid the risk of electric shock.

•  Do not clean the unit with water. Water can enter the unit and damage the insulation, creating a shock hazard. If water enters the unit, unplug it immediately and  

contact Customer Service. It can result in the risk of electric shock.

Содержание RDHC-110

Страница 1: ...en Fran ais 17 Read and retain these instructions for future reference For any Customer Support needs please choose the Support tab on www royalsovereign com USA www royalsovereign ca Canada RDHC 110...

Страница 2: ...Thank you for purchasing the Royal Sovereign Commercial Dehumidifier This manual will provide you with safety information instructions for optimal use and proper care and maintenance of your product...

Страница 3: ...ety Instructions 4 5 Product View 6 7 Handle Installation 8 9 Product Operation 10 11 Maintenance 12 Machine Storage 12 Specifications 13 Error Messages 14 Trouble Shooting 15 Warranty 16 P gina en Fr...

Страница 4: ...hildren should be supervised to ensure that they do not play with or climb on the unit Be sure all packaging materials are removed from the appliances before use It can result in personal injury Do no...

Страница 5: ...e area you wish to dehumid Using an appliance that is the wrong size can waste energy and damage the unit Close all doors and windows to the room for most efficient operation To prevent damage to the...

Страница 6: ...6 Product View Control panel Air Inlet Water tank cover Big Wheel Handle Front View...

Страница 7: ...RDHC 110 7 Air Outlet Built in Handle Support Frame Power cord Radiator Grille Back View...

Страница 8: ...8 Handle Installation Main Body Handle Stainless Steel Bolt Spacer Wheel Spacer Nut Support Frame...

Страница 9: ...ns the tank may need frequent clearing 1 Open the front cover remove the water tank and dispose of any water from the tank 2 Remove the plug and install the included drain pipe to the connector refer...

Страница 10: ...n until the light powers ON Press MINUS and ADD 1 24 to set the start time When the count down is over the fan and compressor will start To power off the unit hold down this button until the button li...

Страница 11: ...5 times and the compressor and fan will shut off Empty the water tank and restart After the water tank is empty the unit will automatically switch to its previous setting with the compressor will rema...

Страница 12: ...nit for an extended period of time please store it per the following steps 1 Clean the filter mesh IMPORTANT The evaporator inside the machine must to dry before the unit is packed as this will avoid...

Страница 13: ...er Consumption Current 728W 6 75 A 86 F 80 RH Noise 60dB A Air Circulation 450m3 hr 264 8 CFM Freon type Capacity R410A 11 6Oz 330g Recommended Room Size 40 50m2 height 2 6m Water tank capacity 5 5L 1...

Страница 14: ...30 minutes and defrosting for 15 minutes A failed temperature sensor should be replaced 3 CL This error message shows when the room temperature is 5 C 41 F A CL code will be displayed and the unit wi...

Страница 15: ...in and or Air out louvers jammed Clear the blockage of the Air in and or Air out louvers No air inlet Filter mesh or air in louver jammed Clean filter according to instructions or clean the louver bl...

Страница 16: ...efective product in original packaging to the address below Royal Sovereign International Inc requires reasonable proof of your date of purchase from an authorized retailer or distributor Therefore yo...

Страница 17: ...onservez ces instructions pour r f rence future Pour tout besoin d assistance la client le veuillez cliquer sur l onglet Assistance sur www royalsovereign com tats Unis www royalsovereign ca Canada RD...

Страница 18: ...shumidificateur commercial de Royal Sovereign Ce guide d utilisation vous fournira des informations de s curit des instructions pour une utilisation optimale ainsi que des soins et un entretien approp...

Страница 19: ...ons de s curit importantes 20 21 Survol du produit 22 23 Installation 24 25 Fonctionnement du produit 26 27 Entretien 28 Entreposage de l appareil 28 Sp cifications 29 Error Messages 30 Messages d err...

Страница 20: ...115 V CA Ne branchez pas d autres appareils dans la m me prise ceci pourrait surcharger le circuit et provoquer un incendie ou une lectrocution Ne retirez pas la broche de mise la terre ronde de la fi...

Страница 21: ...nts Installez l appareil sur un plancher solide et plat pouvant supporter jusqu 110 lb 50 kg L installation sur un plancher faible ou d nivel peut entra ner des risques de dommages mat riels et corpor...

Страница 22: ...22 Product View Panneau des commandes Entr e d air Couvercle du r servoir d eau Grandes roues Poign e Front View...

Страница 23: ...RDHC 110 23 Sortie d air Poign e int gr e Cadre de support Cordon d alimentation Grillage du radiateur Back View...

Страница 24: ...24 Handle Installation Bo tier principal Poign e Boulon d acier inoxydable S parateur Roue S parateur crou Cadre de support...

Страница 25: ...fr quemment 1 Ouvrez le couvercle avant retirez le r servoir d eau et jetez l eau du r servoir 2 Retirez le bouchon et installez le tuyau de vidange fourni sur le raccord voir l illustration ci desso...

Страница 26: ...fonc jusqu ce que le voyant s allume Appuyez sur Moins et ADD 1 24 pour r gler l heure de d but Quand le compte rebours est termin le ventilateur et Pour teindre l appareil maintenez ce bouton enfonc...

Страница 27: ...r s 5 secondes Un signal sonore retentit 15 fois et le compresseur met un signal sonore et le ventilateur s arr tera Videz le r servoir d eau et red marrez Une fois le r servoir d eau vide l appareil...

Страница 28: ...e veuillez le ranger en suivant les tapes suivantes 1 Nettoyer les mailles du filtre IMPORTANT L vaporateur l int rieur de la machine doit s cher avant d emballer l unit car cela vitera d endommager...

Страница 29: ...e et courant 728 W 6 75 A 86 F 80 RH Bruit 60 dB A Circulation de l air 450 m3 hr 264 8 CFM Type et capacit de fr on R410A 11 6 on 330 g Taille de pi ce recommand e 40 50 m2 hauteur 2 6 m Capacit du r...

Страница 30: ...tion pendant 30 minutes et d cong lation pendant 15 minutes Une sonde de temp rature d fectueuse doit tre remplac e 3 CL Ce message d erreur indique que la temp rature ambiante est 5 C 41 F Un code CL...

Страница 31: ...d entr e et ou de sortie d air bloqu es D gagez l obstruction des lamelles d entr e et ou de sortie d air Pas d entr e d air Lamelles d entr e et ou de sortie d air bloqu es Nettoyer le filtre selon...

Страница 32: ...esse ci dessous Royal Sovereign International Inc exige une preuve raisonnable de votre date d achat aupr s d un d taillant ou distributeur autoris Par cons quent vous devez conserver votre re u votre...

Отзывы: