RDHC-150P

PRODUCT VIEW

 

-4-

FRONT

BACK

Control Panel

Top Panel

Filter - located 
behind air inlet 
grid/panel

Inlet grid

Door

Support Base

Drain Hose

 Handle

Wheel

 Warm Air Outlet /Exhaust

Cord Wrap

Handle

Front Support Frame

INSTALLATION AND ASSEMBLY

1. Your dehumidifier is designed for easy use and maintenance. Make sure that the filter is properly installed before use.
2. Keep the unit’s air inlet and outlet at least 24” (61cm) away from any wall/ obstruction.
3. Select a flat, stable surface to place the unit. Do not place on or near heat sources such as stoves, radiators, heaters and avoid placement in direct sunlight.
4. Do not operate the unit in areas where chemicals are stored. Volatile chemicals might damage the unit and may cause the water bucket to leak.

   Note

: Do not tilt the unit over 45° to avoid damaging the compressor.

AUTO PUMP HOSE INSTALLATION

** This Commercial Dehumidifier has a Built-in Auto Pump, which allows water removal of up to 5m (16.4ft) in height.   
     You can therefore run the supplied hose to a drain, sink, etc.
1.  Connect the supplied 5m hose to the dehumidifier. Refer to water pump connection diagram. 
2.  Run the hose to the desired drainage location. Ensure that there is no kinks or knots in the hose. 

Water-pump connection

Содержание RDHC-150P

Страница 1: ...IC PURGE PUMP RDHC 150P Royal Sovereign International Inc Page en Fran ais Read and retain these instructions for future reference For any Customer Support needs please choose the Support tab on www r...

Страница 2: ...CONTENTS Important Safety Instructions 2 3 Product View 4 Assembly 4 Product Operation 5 Maintenance 6 Storage 6 Trouble Shooting 7 Error Messages 7 Specifications 8 Warranty 9 PAGE 1...

Страница 3: ...ised to ensure that they do not play with or climb on the unit Be sure all packaging materials are removed from the dehumidifier before use It can result in personal injury Do not disassemble or modif...

Страница 4: ...detergent To prevent spills and property damage be sure to drain the dehumidifier properly Do not position the dehumidifier so that pets or house plants are exposed to the direct air flow It can resul...

Страница 5: ...n or near heat sources such as stoves radiators heaters and avoid placement in direct sunlight 4 Do not operate the unit in areas where chemicals are stored Volatile chemicals might damage the unit an...

Страница 6: ...pt to start stop and restart the unit without waiting at least 3 minutes Failure to do so may cause damage to the compressor and or cause unit failure 2 The unit will automatically sense when it needs...

Страница 7: ...re control panel and power cord if necessary The exhaust panel should simply be dusted It should not be immersed in water No part of the unit should be placed in a dishwasher To extend the life of the...

Страница 8: ...Close the doors and windows 4 Consult a certified technician or contact Royal Sovereign customer service Water leaks from the unit 1 The unit may be unstable or not upright 2 The tank or drain hose is...

Страница 9: ...ints Day 90 F 90 RH Drainage Type Auto Pump 16 4ft 5m Thermostat Range Adjustable Operating Temperature Range 5 38 C 41 100 4 F Washable Filter Yes Timer 1 24 Hours Applicable Area 150 sq m 1600 sq ft...

Страница 10: ...efective product in original packaging to the address below Royal Sovereign International Inc requires reasonable proof of your date of purchase from an authorized retailer or distributor Therefore yo...

Страница 11: ...DHC 150P Royal Sovereign International Inc Page en fran ais Lisez et conservez ces instructions pour toute r f rence ult rieure Pour tout besoin de support client veuillez choisir l onglet Support la...

Страница 12: ...Instructions de s curit importantes 11 12 Survol du produit 13 Assemblage 13 Fonctionnement du produit 14 Entretien 15 Entreposage 16 D pannage 16 Messages d erreur 16 Sp cifications 17 Garantie 18 P...

Страница 13: ...ce que tous les mat riaux d emballage soient retir s du d shumidificateur avant de l utiliser Cela peut entra ner des blessures Ne d montez pas et ne modifiez pas le d shumidificateur ou le cordon d...

Страница 14: ...es dommages mat riels veillez bien vidanger le d shumidificateur Ne placez pas le d shumidificateur de mani re ce que les animaux domestiques ou les plantes d int rieur soient expos s au flux d air di...

Страница 15: ...eur telles que des po les des radiateurs des appareils de chauffage et vitez de le placer en plein soleil 4 N utilisez pas l appareil dans des endroits o sont stock s des produits chimiques Les produi...

Страница 16: ...r sultats REMARQUE N essayez JAMAIS de d marrer d arr ter et de red marrer l unit sans attendre au moins 3 minutes Le non respect de cette consigne peut endommager le compresseur et ou provoquer une...

Страница 17: ...n d alimentation si n cessaire Le panneau d vacuation doit simplement tre d poussi r Il ne doit pas tre immerg dans l eau Aucune partie de l appareil ne doit tre plac e dans un lave vaisselle Pour pro...

Страница 18: ...fen tres 4 Consultez un technicien certifi ou contactez le service client le de Royal Sovereign Fuites d eau de l unit 1 L appareil peut tre instable ou ne pas se tenir droit 2 Le r servoir ou le tuya...

Страница 19: ...de drainage Pompe automatique 5 m 16 4 pi Port e du thermom tre Adjustable Port e de la temp rature de fonctionnement 5 38 C 41 100 4 F Filtre lavable Oui Minuterie 1 24 heures Zone d application 150...

Страница 20: ...emballage d origine l adresse ci dessous Royal Sovereign International Inc exige une preuve raisonnable de la date d achat aupr s d un d taillant ou d un distributeur autoris Par cons quent vous devez...

Отзывы: